Elmo Rietschle 2BH1900
Elmo Rietschle ·Made in Germany · In Active Production

Elmo Rietschle 2BH1900

Elmo Rietschle 2BH1900 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure -190 mbar, Motor power 8.6 kW, Noise level 75 dB.

The 2BH1900 is a side-channel regenerative blower in the Elmo Rietschle G-BH1 series, configured for 50/60 Hz operation with a 17.3/19.9 kW IE3 motor. It delivers up to 410 mbar positive pressure and -350 mbar vacuum at 50 Hz, distinguishing it as the highest-capacity model among the listed siblings (2BH1009 through 2BH1023). It is intended for continuous-duty pressure or vacuum supply in industrial processes requiring oil-free, contact-free gas movement.

Max. differential pressure
-190 mbar
Motor power
8.6 kW
Noise level
75 dB
Weight
183 kg

Elmo Rietschle G-BH1 Series — Model Comparison & Selection

Model Motor power, kWNoise level, dBWeight, kgMax. differential pressure, mbarCurrent, AProtection rating
2BH1900 Current 8.671183-19030.8IP55
2BH1009 ——————
2BH1014 0.325711-553.2–6.5IP55
2BH1015 1.36421-1808–16IP55
2BH1023 1.756969-19010–20IP55
2BH1035 2.26470-14014.3–27IP55
2BH1100 0.25310-1201.39 Δ / 0.80 YIP 55
2BH1200 0.294057-401.38 0.8 YIP55
2BH1300 0.2910051-1001.9IP 55
2BH1310 0.75616-2503.8 Δ / 2.20 YIP55
2BH1330 0.298051—1.74 Δ / 1.0 YIP55
2BH1400 0.956116-1805.6IP55
2BH1410 26528-3006.9IP55
2BH1430 1.164161104.2IP55
2BH1490 0.956116-1404.8 VVIP55
2BH1500 0.956521-904.2IP55
2BH1510 47148-4007.6–15.2IP55
2BH1530 1.66925-904.7IP55
2BH1590 1.36121-1902.75IP55
2BH1600 1.7572311309.9IP55
2BH1610 2.575481606IP55
2BH1630 2.56436-16017.1IP55
2BH1640 4.66565-240–26017.1IP55
2BH1690 2.56434-2009.9IP55
2BH1800 5.87713126011–22IP55
2BH1810 9.974188-46030.8IP55
2BH1830 5.875133-16019.4IP55
2BH1910 12.676295-22026.4IP55
2BH1930 8.675212-8017.6–35.2IP55
2BH1940 19.973303-15063.1IP55
2BH1943 17.377330-16072.2 UU / 36.1 UIP55

Full specifications

Core Performance & Functional Specifications
Max. differential pressure -190 mbar (50 Hz)
60 Hz: -150 mbar
Motor power 8.6 kW (50 Hz)
60 Hz: 9.9 kW
Noise level 71 dB (50 Hz)
60 Hz: 75 dB
Max. differential pressure vacuum mfr -150 mbar (60 Hz)
Type No. mfr 2BH1900-1AK01 (50 Hz)
Type No. mfr 2BH1900-1AK01 (60 Hz)
Dimensions, Weight & Mechanical Design
Weight 183 kg
Electrical, Power & Drive Specifications
Current 30.8 A (50 Hz)
60 Hz: 35.2 A
Frequency 50 Hz
Power supply 3~ 50/60 Hz
Voltage 190-210 V (50 Hz)
60 Hz: 190-210 / 380-420 V
Rated voltage mfr 200 V (60 Hz)
Rated current mfr 35.2 A (60 Hz)
Efficiency class mfr IE3 (50 Hz)
Efficiency class mfr NP (60 Hz)
Frequency (alt var) mfr 60 Hz
Operating Conditions, Environment & Protection
Protection rating IP55
Sound pressure level mfr 71 dB(A) (50 Hz)
Sound pressure level mfr 75 dB(A) (60 Hz)

Description

Construction and series positioning

Operating behavior

Installation and operation

Integration & Operating Notes

Electrical
Dual-voltage motor must be linked to the correct supply

The winding is rated 220–240/380–420 V at 50 Hz and 440–480 V at 60 Hz. Connecting the motor to a voltage outside the matching range will cause overheating or loss of torque; verify the terminal-box link configuration against the nameplate before first start.

Factory Specification Sheet
Process Limits
Do not exceed 410 mbar pressure or -350 mbar vacuum at 50 Hz

Operating beyond the maximum differential pressure in either direction increases motor current and internal temperature, risking winding damage and bearing overload. At 60 Hz the limits shift to 380 mbar pressure and -380 mbar vacuum; size the process restriction accordingly.

Factory Specification Sheet
Cooling & Media
Motor cooling airflow must remain unobstructed

The IP55 motor relies on fan-driven air over its fins. Install the blower with sufficient clearance around the fan cowl and avoid recirculating hot exhaust air; ambient temperature and altitude derating data are not supplied and should be confirmed with the manufacturer for continuous full-load operation.

Factory Specification Sheet
Maintenance
No maintenance schedule supplied; establish per manufacturer

The document digests contain no service intervals, error codes, or consumable lists. Bearing lubrication, filter replacement (if inlet filtration is fitted), and impeller clearance checks should be scheduled according to Elmo Rietschle's G-BH1 series maintenance instructions for this frame size.

Factory Specification Sheet

Selection & Integration Q&A

When should I choose the 2BH1900 instead of the smaller 2BH1009, 2BH1014, 2BH1015, or 2BH1023?

Choose the 2BH1900 when the duty point requires up to 410 mbar pressure or -350 mbar vacuum at 50 Hz with a 17.3 kW motor. The smaller siblings suit lower flow or pressure demands; the 2BH1900 is the highest-capacity listed model and should be selected only when their limits are insufficient.

What supply and protection equipment does the 2BH1900 require?

It needs a three-phase supply matching the winding link: 220–240/380–420 V at 50 Hz or 440–480 V at 60 Hz. Provide a motor-protection circuit breaker or overload relay set to the rated current (57.0/32.7 A at 50 Hz; 32.4 A at 60 Hz) and a contactor rated for the 17.3–19.9 kW load.

What maintenance and accessories are not included in the base delivery?

No maintenance schedule, spare-parts list, inlet filter, silencer, flexible connectors, or mounting pads are included in the supplied facts. Establish bearing and filter service intervals from the G-BH1 manual, and specify suction/discharge silencers and vibration isolators separately to meet noise and piping-load requirements.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Technical Data Sheet — 2BH1900 IE3 vacuum pump (EN)
Datasheet ·648,6 КБ ·2 pp.