Elmo Rietschle 2BH1940
Elmo Rietschle ·Made in Germany · In Active Production

Elmo Rietschle 2BH1940

Elmo Rietschle 2BH1940 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure -150 mbar, Motor power 17.3 kW, Noise level 77 dB.

The Elmo Rietschle 2BH1940 is a side-channel regenerative ring blower in the G-BH1 series, configured as a single-stage, contactless impeller unit. It is positioned above the 2BH10xx siblings for higher flow and pressure duties. It serves as a vacuum or pressure source in pneumatic conveying, aeration, and industrial process air systems.

Max. differential pressure
-150 mbar
Motor power
17.3 kW
Noise level
77 dB
Weight
303 kg

Elmo Rietschle G-BH1 Series — Model Comparison & Selection

Model Motor power, kWNoise level, dBWeight, kgMax. differential pressure, mbarCurrent, AProtection rating
2BH1940 Current 19.973303-15063.1IP55
2BH1009 ——————
2BH1014 0.325711-553.2–6.5IP55
2BH1015 1.36421-1808–16IP55
2BH1023 1.756969-19010–20IP55
2BH1035 2.26470-14014.3–27IP55
2BH1100 0.25310-1201.39 Δ / 0.80 YIP 55
2BH1200 0.294057-401.38 0.8 YIP55
2BH1300 0.2910051-1001.9IP 55
2BH1310 0.75616-2503.8 Δ / 2.20 YIP55
2BH1330 0.298051—1.74 Δ / 1.0 YIP55
2BH1400 0.956116-1805.6IP55
2BH1410 26528-3006.9IP55
2BH1430 1.164161104.2IP55
2BH1490 0.956116-1404.8 VVIP55
2BH1500 0.956521-904.2IP55
2BH1510 47148-4007.6–15.2IP55
2BH1530 1.66925-904.7IP55
2BH1590 1.36121-1902.75IP55
2BH1600 1.7572311309.9IP55
2BH1610 2.575481606IP55
2BH1630 2.56436-16017.1IP55
2BH1640 4.66565-240–26017.1IP55
2BH1690 2.56434-2009.9IP55
2BH1800 5.87713126011–22IP55
2BH1810 9.974188-46030.8IP55
2BH1830 5.875133-16019.4IP55
2BH1900 8.671183-19030.8IP55
2BH1910 12.676295-22026.4IP55
2BH1930 8.675212-8017.6–35.2IP55
2BH1943 17.377330-16072.2 UU / 36.1 UIP55

Full specifications

Core Performance & Functional Specifications
Max. differential pressure -150 mbar (50 Hz)
60 Hz: -110 mbar
Motor power 17.3 kW (50 Hz)
60 Hz: 19.9 kW
Noise level 73 dB (50 Hz)
60 Hz: 77 dB
Dimensions, Weight & Mechanical Design
Weight 303 kg (50 Hz)
60 Hz: 303 kg
Number of stages 1
Electrical, Power & Drive Specifications
Current 63.1 A (50 Hz)
60 Hz: 72.2 / 36.1 A
Frequency 50 Hz (50 Hz)
60 Hz: 60 Hz
Voltage 190-210 V (50 Hz)
60 Hz: 190-210 / 380-480 V
Operating Conditions, Environment & Protection
Protection rating IP55
Operating temperature 25 degC

Description

Construction and Series Positioning

Behavior Under Load and in Different Media

Installation, Connection, and Control

Integration & Operating Notes

Process Limits
Do not operate at zero flow without thermal check

Side-channel blowers reach their highest discharge temperature at closed-valve (zero flow) operation. The 2BH1940 must not be run continuously against a closed suction or discharge unless the manufacturer confirms the permissible temperature rise for this frame; install a relief valve or bypass if the process can dead-head.

General side-channel blower engineering practice; model-specific data not supplied
Mounting
Mount on a flat, rigid base to avoid casing distortion

The blower casing and motor are a single rigid assembly; bolting to an uneven surface can distort the close impeller-to-casing clearance. Use a machined base or shims and tighten fasteners evenly. Exact bolt pattern and weight were not provided and must be taken from the 2BH1940 dimensional drawing.

Elmo Rietschle G-BH1 series documentation (model-specific drawing required
Electrical
Motor data and starter sizing must be confirmed per nameplate

No electrical specifications were supplied for the 2BH1940. Voltage, frequency, current, and starting method must be read from the motor nameplate and the official datasheet. Direct-on-line starting of a large frame draws high inrush current; verify the supply and protection coordination before commissioning.

Motor nameplate / Elmo Rietschle 2BH1940 datasheet (not supplied

Selection & Integration Q&A

When should I choose the 2BH1940 rather than one of the smaller 2BH10xx siblings?

Pick the 2BH1940 only when the required flow/pressure point exceeds the range of the 2BH1023 and the other smaller frames. If the duty point fits a smaller sibling, choose it to avoid oversizing, higher energy use, and unstable operation near the blower's flow limit.

What adjacent equipment must be verified before integrating the 2BH1940?

Confirm the motor nameplate voltage/frequency/current against the supply, size the starter or VFD for the frame's inrush, and match suction/discharge flange sizes to the 2BH1940 drawing. Add a suction filter and, if the process can dead-head, a relief valve or bypass.

What mounting and duty-cycle limits apply to the 2BH1940?

Mount on a flat rigid base to preserve impeller clearance, and keep the cooling-air path to the motor unobstructed. Continuous operation at closed suction or discharge raises temperature; verify permissible thermal limits with the manufacturer before specifying a dead-head duty cycle.

What maintenance items and accessories are not included in the base delivery?

The base unit does not include suction filters, relief valves, silencers, flexible connectors, or mounting pads; these must be ordered separately. Bearing inspection intervals and any replacement parts must be taken from the official 2BH1940 manual, which was not supplied with this record.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Technical Data Sheet — 2BH1940 IE3 vacuum pump (EN)
Datasheet ·316,8 КБ ·2 pp.
View PDF