Peter Huber Kältemaschinenbau Unistat P920w Dynamisches

Peter Huber Kältemaschinenbau Unistat P920w Dynamisches — Temperature control units.

The Unistat P920w Dynamisches is a water-cooled refrigerated heating circulator with a magnetically coupled stainless steel pump, covering -90 to 200 °C with 12 kW heating. Its high-discharge-pressure 'P' pump targets high-pressure-drop loops in flow-through chemistry and semiconductor processes. It serves as a dynamic temperature control source for externally closed or open applications.

Peter Huber Kältemaschinenbau Unistat Series — Model Comparison & Selection

Model Noise level, dBAmbient temperature limit, °CDisplay resolutionPower supplyPump connectionPump type
Unistat P920w Dynamisches Current —5–400, 01400V 3~ 50HzM38x1, 5 AG malemagnetically coupled, st
Unistat 1005w Dynamisches —5–400, 01400V 3~ 50HzM30x1, 5 AG malePressure pump, variable
Unistat 1015w Dynamisches —5–400, 01400V 3~ 50HzM30x1, 5 AG malemagnetically coupled, st
Unistat 705w Dynamisches —5–400, 01230V 1~ 50HzM24x1, 5 AG malePressure pump, variable
Unistat 815w Dynamisches 605–400, 01400V 3~ 50HzM30x1, 5 AG malePressure pump, variable
Unistat 825w Dynamisches —5–400, 01400V 3~ 50HzM30x1, 5 AG malePressure pump, variable
Unistat 905w Dynamisches —5–400, 01 K208V 3~ 60HzM30x1, 5 AG malemagnetically coupled, st
Unistat 912w Dynamisches 655–400, 01400V 3~ 50HzM30x1, 5 AG malemagnetically coupled, st
Unistat 915w Dynamisches 645–400, 01400V 3~ 50HzM30x1, 5 AG malemagnetically coupled, st
Unistat 920w Dynamisches 715–400, 01400V 3~ 50HzM38x1, 5 AG malemagnetically coupled, st
Unistat 930w Dynamisches —5–400, 01460V 3~ 60HzM38x1, 5 AG malemagnetically coupled, st
Unistat 950w Dynamisches —5–400, 01400V 3~ 50Hzflange DN40 PN10/40 EN10magnetically coupled, st
Unistat P815 Dynamisches 645–400, 01400V 3~ 50HzM30x1, 5 AG malemagnetically coupled, st
Unistat P815w Dynamisches —5–400, 01400V 3~ 50HzM30x1, 5 AG malemagnetically coupled, st
Unistat P825 Dynamisches —5–400, 01400V 3~ 50HzM30x1, 5 AG malemagnetically coupled, st
Unistat P825w Dynamisches —5–400, 01400V 3~ 50HzM30x1, 5 AG malemagnetically coupled, st
Unistat P905 Dynamisches —5–350, 01460V 3~ 60HzM30x1, 5 AG malemagnetically coupled, st
Unistat P905w Dynamisches —5–400, 01460V 3~ 60HzM30x1, 5 AG malemagnetically coupled, st
Unistat P912w Dynamisches 655–400, 01460V 3~ 60HzM30x1, 5 AG malemagnetically coupled, st
Unistat P915w Dynamisches 645–400, 01400V 3~ 50HzM30x1, 5 AG malemagnetically coupled, st
Unistat P925w Dynamisches —5–400, 01400V 3~ 50HzM38x1, 5 AG malemagnetically coupled, st
Unistat P930w Dynamisches —5–400, 01400V 3~ 50HzM38x1, 5 AG malemagnetically coupled, st
Unistat P950w Dynamisches —5–400, 01400V 3~ 50Hzflange DN40 PN10/40 EN10magnetically coupled, st

Full specifications

Core Performance & Functional Specifications
Control output POKO ONE
Expansion volume 29 l
Filling volume 12 l
Heating capacity 12 kW
Pump connection M38x1, 5 AG male
Pump speed adjustable Yes
Pump type magnetically coupled, stainless steel
External sensor connection Pt100
Temperature range -90...200 °C
Dimensions, Weight & Mechanical Design
Weight 916 kg
Electrical, Power & Drive Specifications
Current consumption 38 A (max.)
Power supply 400V 3~ 50Hz
Interfaces, Connections & Control
Controller Pilot ONE
Display resolution 0, 01 K
Digital interface Ethernet, USB (Host u. Device), RS232
Materials, Media & Process Compatibility
Maximum viscosity 50 mm²/s
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C
Cooling water connection G3/4 male
Cooling water consumption 730 l/h (at 15°C, flow 0°C)
Cooling water differential pressure 1 bar (min.)
Cooling Water Pressure 6 bar (max.)
Protection rating IP20
Standards, Safety & General Data
Safety class III / FL

Description

Construction and series positioning

Behavior and media

Installation, control and operation

Integration & Operating Notes

Mounting
Install only outside ATEX zones; Ex px cabinet required otherwise

The unit must not be installed or started up within an ATEX zone; without an Ex px cabinet the unit is not protected against explosion. Site selection must exclude ATEX zones, and Ex px cabinet operation requires the separate ATEX annex and only the model/serial number stated on the Ex px cabinet rating plate is suitable.

Operation Manual, Section 1.3.3 / page 15-16
Mounting
Transport upright and emptied; casters are not for transport

Only transport the temperature control unit in an upright position; horizontal transport damages the compressor. Only an emptied unit may be moved; filled transport risks thermal fluid overflow. Casters (if present) are not suitable for transport and carry only 25% of total mass symmetrically; use an industrial truck. Leveling feet must be unscrewed/activated and parking brakes engaged before commissioning.

Operation Manual, page 22
Process Limits
Cooling water 5–20 °C; insulate pipes below condensation point

This temperature control unit is designed to operate with cooling water intake temperature between 5 °C and 20 °C. When cooling water temperatures fall below the condensation point, it is essential to insulate the cooling water pipes in the unit. Rated output data assume 20 °C room temperature, 15 °C cooling water inlet and 1 bar differential pressure; higher cooling water temperature reduces cooling power.

Technical Data, page 2
Process Limits
Cooling water circuit materials restrict water quality

Materials used in the cooling water circuit include copper, stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM. Only compatible cooling water may be used; water quality must be checked against these materials before connection.

Technical Data, page 2
Control & I/O
Process Safety mode requires compressor set to Permanently ON

In Process safety mode, when the set overtemperature trigger value is reached the controller releases maximum cooling capacity instead of switching off all poles of the temperature control. This mode requires the compressor to be set to Permanently ON to keep cooling active at the OT trigger.

Operation Manual, Section 1.7.2 / page 20
Control & I/O
Power Failure Auto resumes temperature control after outage

If temperature control is active during a power outage, the process will automatically continue after the power outage when Power Failure Auto is enabled. Choose the power-interruption behavior according to whether unattended restart is acceptable for the process.

Operation Manual, page 20
Maintenance
Shut off cooling water even for overnight downtimes

Shut off the cooling water supply to the temperature control unit even for shorter downtimes (e.g. overnight) to prevent water damage and unnecessary load on the cooling water circuit.

Operation Manual, page 29
Maintenance
Periodically check hoses and connections; replace as needed

Check periodically for leaks and the quality of the hose and hose connections and take suitable measures (replace) as required. Work on the coolant circuit must be carried out by approved refrigeration/air-conditioning system contractors.

Operation Manual, page 29; Section 1.4.2 / page 19
Maintenance
Refrigerant charge and GWP for leak checks and reporting

Refrigerant R-452A with GWP 2141 and 4.55 kg charge (9.7 t CO2e), plus R-23 second stage with GWP 14800 and 1.9 kg (28.1 t CO2e). Relevant for refrigerant handling, leak checks and environmental reporting.

Technical Data, page 1

Selection & Integration Q&A

When should I choose the Unistat P920w Dynamisches instead of a sibling w Dynamisches model such as the 815w or 1005w?

Choose the P920w when the loop has high pressure drop (flow-through chemistry, semiconductor processes) requiring the high-discharge-pressure 'P' pump. Sibling w models share water cooling but lack the P pump designation; select them for lower pressure-drop duty.

What mating fittings and cooling water supply must be provided for integration?

Pump connections are M38x1.5 AG male using bore shape Y (60°) per DIN 3863 with ball socket per DIN 3863 and sleeve nut per DIN 3870. Cooling water connection is G3/4 male; supply 5–20 °C at min. 1 bar differential, max. 6 bar, 730 l/h at 15 °C.

What are the electrical and environmental limits for installing this unit?

Supply 400 V 3~ 50 Hz, max. 38 A, with ±5% voltage and ±2% frequency tolerance (not all combinations allowed). Leakage current >3.5 mA; Class A EN55011. Ambient 5–40 °C; IP20; must not be installed in an ATEX zone.

What maintenance and accessories are required beyond base delivery?

Base delivery includes cable but no plug for three-phase <63 A; provide a suitable plug. Periodically check hoses/connections and replace as needed; shut off cooling water overnight. Refrigerant work requires approved contractors. A drip tray must be installed below the unit.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Unistat P920w Technical Data
Datasheet ·61,0 КБ ·2 pp.
View PDF
PDF
Unistat® Operation Manual — Unistat® 5, Unistat® Pilot ONE®
Manual ·3,6 МБ ·100 pp.
View PDF
PDF
Unistat Operation Manual
Manual ·3,7 МБ ·102 pp.
View PDF