Elmo Rietschle 2BH1690
Elmo Rietschle ·Made in Germany · In Active Production

Elmo Rietschle 2BH1690

Elmo Rietschle 2BH1690 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure -200 mbar, Motor power 2.5 kW, Noise level 70 dB.

The 2BH1690 is a single-stage side-channel blower from Elmo Rietschle's G-BH1 series, driven by an IE3-class motor rated 3.45 kW at 50 Hz (380–420 V delta) and 6.6 kW at 60 Hz. It delivers up to 250 mbar differential pressure in pressure mode and -200 mbar in vacuum mode at 50 Hz, with a 38 kg mass and IP55 protection. This modification is the higher-capacity unit within the 2BH1 series, intended for continuous-duty vacuum or pressure generation in industrial processes.

Max. differential pressure
-200 mbar
Motor power
2.5 kW
Noise level
70 dB
Pumping speed
170 m³/h
Weight
34 kg

Elmo Rietschle G-BH1 Series — Model Comparison & Selection

Model Motor power, kWNoise level, dBWeight, kgMax. differential pressure, mbarCurrent, AProtection rating
2BH1690 Current 2.56434-2009.9IP55
2BH1009 ——————
2BH1014 0.325711-553.2–6.5IP55
2BH1015 1.36421-1808–16IP55
2BH1023 1.756969-19010–20IP55
2BH1035 2.26470-14014.3–27IP55
2BH1100 0.25310-1201.39 Δ / 0.80 YIP 55
2BH1200 0.294057-401.38 0.8 YIP55
2BH1300 0.2910051-1001.9IP 55
2BH1310 0.75616-2503.8 Δ / 2.20 YIP55
2BH1330 0.298051—1.74 Δ / 1.0 YIP55
2BH1400 0.956116-1805.6IP55
2BH1410 26528-3006.9IP55
2BH1430 1.164161104.2IP55
2BH1490 0.956116-1404.8 VVIP55
2BH1500 0.956521-904.2IP55
2BH1510 47148-4007.6–15.2IP55
2BH1530 1.66925-904.7IP55
2BH1590 1.36121-1902.75IP55
2BH1600 1.7572311309.9IP55
2BH1610 2.575481606IP55
2BH1630 2.56436-16017.1IP55
2BH1640 4.66565-240–26017.1IP55
2BH1800 5.87713126011–22IP55
2BH1810 9.974188-46030.8IP55
2BH1830 5.875133-16019.4IP55
2BH1900 8.671183-19030.8IP55
2BH1910 12.676295-22026.4IP55
2BH1930 8.675212-8017.6–35.2IP55
2BH1940 19.973303-15063.1IP55
2BH1943 17.377330-16072.2 UU / 36.1 UIP55

Full specifications

Core Performance & Functional Specifications
Max. differential pressure -200 mbar (50 Hz)
60 Hz: -190 mbar
Motor power 2.50 kW (50 Hz)
60 Hz: 3.00 kW
Noise level 64 dB (50 Hz)
60 Hz: 70 dB
Pumping speed 170 m³/hour (50 Hz)
60 Hz: 170 m³/hour
Max. differential pressure (vacuum) mfr -240 mbar (60 Hz)
Max. differential pressure vacuum mfr -190 mbar (60 Hz)
Order No. mfr 2BH1690-0AK11
Max. differential pressure (alt 50 Hz) mfr 250 mbar (50 Hz)
Dimensions, Weight & Mechanical Design
Weight 34 kg
Number of stages 1
Electrical, Power & Drive Specifications
Current 9.9 A (50 Hz)
60 Hz: 12.0 A
Frequency 50/60 Hz
Power supply 3~ 50/60 Hz
Voltage 190-210 V (50 Hz)
60 Hz: 190-210 YY / 380-420 Y V
Power consumption P at pump shaft mfr 3.45 kW (50 Hz, 380-420 V delta)
Power consumption P at pump shaft mfr 3.85 kW (50 Hz, 660-725 V star)
Power consumption P at pump shaft mfr 6.6 kW (60 Hz, 440-480 V delta)
Power consumption P at pump shaft mfr 6.6 kW (60 Hz, 460 V delta)
Efficiency class mfr IE3
Rated current mfr 12.0 ΥΥ A (60 Hz)
Efficiency class mfr IE3 (50 Hz)
Efficiency class mfr NP (60 Hz)
Operating Conditions, Environment & Protection
Protection rating IP55
Operating temperature 25 degC
Sound pressure level mfr 64 dB(A) (50 Hz)
Sound pressure level mfr 70 dB(A) (60 Hz)

Description

Construction and series positioning

Performance behavior

Installation and operation

Integration & Operating Notes

Process Limits
Differential pressure must not exceed 250 mbar in pressure mode

The maximum differential pressure is 250 mbar for pressure operation at both 50 and 60 Hz. In vacuum mode, the limit is -200 mbar at 50 Hz and -240 mbar at 60 Hz. Exceeding these limits can cause overheating, increased noise, and mechanical stress on the impeller and bearings.

Technical Data Sheet — 2BH1690 IE3 vacuum pump (EN)
Mounting
Install with sufficient clearance for motor cooling

The IP55 motor relies on ambient air for cooling. Ensure unobstructed airflow around the motor fins and avoid enclosing the blower in a tight compartment. The 34 kg weight requires a rigid mounting surface or bracket capable of withstanding vibration during operation.

Technical Data Sheet — 2BH1690 IE3 vacuum pump (EN)
Maintenance
Regular inspection of bearings and seals is recommended

The data sheet does not specify maintenance intervals. In practice, check for unusual noise, vibration, and temperature rise at regular intervals. Replace bearings and seals according to the manufacturer's service manual or after extended continuous operation. Keep the impeller and inlet free of debris to maintain performance.

Technical Data Sheet — 2BH1690 IE3 vacuum pump (EN)

Selection & Integration Q&A

When should I choose the 2BH1690 instead of a smaller sibling like the 2BH1023?

Choose the 2BH1690 when your process requires differential pressures up to 250 mbar or vacuum to -200 mbar at 50 Hz, and a shaft power of 3.45 kW. The 2BH1690 also provides higher power at 60 Hz (6.6 kW) for more demanding applications.

What are the requirements for the power supply and motor protection when integrating the 2BH1690?

The motor must be connected according to the nameplate voltage and frequency: at 50 Hz, 380–420 V delta or 660–725 V star; at 60 Hz, 440–480 V delta. Use a motor protection switch or VFD rated for the operating current (6.7 A at 50 Hz delta, 6.6 A at 60 Hz delta). Ensure the supply can handle the starting current, which may be several times the rated current.

What maintenance items and accessories are not included with the base blower?

The base delivery includes the blower and motor only. Additional items such as inlet/outlet silencers, filters, flexible connectors, and mounting feet are not included and must be ordered separately. Maintenance parts like bearings, seals, and gaskets are also not included. Refer to the service manual for recommended spare parts and intervals.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Technical Data Sheet — 2BH1690 IE3 vacuum pump (EN)
Datasheet ·482,9 КБ ·2 pp.
View PDF