Peter Huber Kältemaschinenbau Unistat 620w Dynamisches
Peter Huber Kältemaschinenbau Unistat 620w Dynamisches — Temperature control units with Noise level 68 dB.
The Unistat 620w Dynamisches is a water-cooled refrigerated heating circulator with a magnetically coupled stainless-steel pump, covering -60 to 200 °C with 12 kW heating capacity. It is the largest water-cooled dynamic modification in the Unistat 5xx/6xx series, distinguished by its external transformer and G3/4 cooling-water connection. It serves as a high-capacity temperature source for externally closed process loops requiring precise Pt100 control via the Pilot ONE controller.
Peter Huber Kältemaschinenbau Unistat Series — Model Comparison & Selection
| Model | Noise level, dB | Display resolution | Heating capacity, W | Pump connection | Pump type | Temperature range, °C |
|---|---|---|---|---|---|---|
| Unistat 620w Dynamisches Current | 68 | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 510w Dynamisches | 60 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat 515w Dynamisches | — | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat 520w Dynamisches | 61 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 525 Dynamisches | 56 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 525w Dynamisches | 61 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 527w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 530w Dynamisches | 59 | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 540w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 545w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 610w Dynamisches | 62 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 615w Dynamisches | 62 | 0, 01 | 12000 | M30x1, 5 AG male | Pressure pump, variable | -60–200 |
| Unistat 625w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 630w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 635w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 640w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 645w Dynamisches | — | 0, 01 | 36000 | flange DN32 PN10/40 EN10 | magnetically coupled, st | -60–200 |
| Unistat 650w Dynamisches | 73 | 0, 01 | 48000 | flange DN32 PN10/40 EN10 | magnetically coupled, st | -60–200 |
| Unistat 680w Dynamisches | — | 0, 01 | 96000 | DN50 PN16 (DIN EN 1092-1 | magnetically coupled, st | -60–200 |
| Unistat GL 530w Dynamisches | 61 | 0, 01 | 6000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 535w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 540w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 550w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 560w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 570w Dynamisches | — | 0, 01 | 48000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P530w Dynamisches | 61 | 0, 01 | 6000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P535w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P540w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P550w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P560w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P570w Dynamisches | — | 0, 01 | 48000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat P510 Dynamisches | 60 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat P510w Dynamisches | 60 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat P515w Dynamisches | — | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat P520 Dynamisches | — | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P520w Dynamisches | 61 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P525 Dynamisches | 56 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P525w Dynamisches | 61 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P527w Dynamisches | 57 | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P530w Dynamisches | 62 | 0.01 | 12000 | M38x1,5 AG male | magnetically coupled, st | -55–250 |
| Unistat P540w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P545w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P610 Dynamisches | — | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P610w Dynamisches | 62 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P615 Dynamisches | — | 0, 01 | 12000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P615w Dynamisches | 62 | 0, 01 | 12000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P620w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P625w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P630w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P635w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P645w Dynamisches | — | 0, 01 | 36000 | flange DN32 PN10/40 EN10 | magnetically coupled, st | -60–200 |
| Unistat P650w Dynamisches | — | 0, 01 | 48000 | flange DN32 PN10/40 EN10 | magnetically coupled, st | -60–200 |
Full specifications
| Noise level | 68 dB(A) |
| Control output | POKO ONE |
| Heating capacity | 12 kW |
| Pump connection | M38x1, 5 AG male |
| Pump speed adjustable | Yes |
| Pump type | magnetically coupled, stainless steel |
| External sensor connection | Pt100 |
| Temperature range | -60...200 °C |
| Weight | 616 kg |
| Controller | Pilot ONE |
| Display resolution | 0, 01 K |
| Digital interface | Ethernet, USB (Host u. Device), RS232 |
| Maximum viscosity | 100 mm²/s |
| Ambient temperature limit | 5...40 °C |
| Cooling water connection | G3/4 male |
| Cooling water consumption | 760 l/h (at 15°C, flow 0°C) |
| Cooling water differential pressure | 1 bar |
| Cooling Water Pressure | 6 bar |
| Protection rating | IP20 |
| Safety class | III / FL |
Description
Construction and series positioning
- The 620w is a free-standing, water-cooled refrigerated heating circulator; the 'w' suffix denotes water cooling, as opposed to air-cooled (no suffix) or water/air-cooled (wl) siblings.
- Within the Unistat 5xx/6xx family, it is the largest water-cooled dynamic variant listed, with a 616 kg mass and 19.9 l expansion tank; smaller siblings (510w, 515w, 520w, 525) differ in noise level and capacity.
- The pump is magnetically coupled and stainless steel, with M38x1.5 male connections; cooling water connections are G3/4 male.
- Electrical supply is provided via an external transformer supplied as standard, so the installation footprint includes both the unit and the transformer.
Behavior under load and media
- Temperature range is -60 to 200 °C; heating capacity is 12 kW. No cooling capacity curve points were provided, so cooling performance must be referenced to the datasheet at stated conditions.
- The datasheet notes that cooling power drops as cooling water temperature rises above the 15 °C reference, and cooling water flow rate may increase; the 760 l/h consumption figure is tied to 15 °C cooling water and 0 °C flow.
- The unit is rated safety class III / FL, permitting flammable heat transfer fluids with a fire point ≥65 °C; ethanol requires supervised operation.
- Low-level protection uses a pressure sensor in the heat transfer fluid circuit; air ingress or low fill level interrupts circulation and temperature control.
Installation, control and operation
- The Pilot ONE controller with POKO ONE control output provides a 0.01 K display resolution and interfaces: Ethernet, USB (host and device), RS232; an external Pt100 sensor can be connected.
- Cooling water inlet temperature must be 5–20 °C; pipes must be insulated if below the condensation point. Cooling water pressure limit is 6 bar, differential pressure 1 bar.
- Ambient temperature must be 5–40 °C; IP20 protection requires a dry indoor location. A drip tray for condensation water/heat transfer fluid must be installed below the unit.
- The unit must not be installed in an ATEX zone; medical-device and direct-food applications are not permissible.
- Minimum filling capacity is 8.9 l; the expansion vessel must remain unlocked for externally closed applications and locked for externally open (bath) applications.
Integration & Operating Notes
The IP20 rating and the manual's prohibition of ATEX-zone installation mean the unit must be placed in a dry, protected indoor environment. Explosion protection would require a separate Ex px cabinet with its own ATEX annex and rating plate; the standard unit is not protected against explosion.
The datasheet states leakage current >3.5 mA, which affects protective earthing and residual current device selection. The unit is fed from an external transformer supplied as standard, so both the transformer and the unit must be accommodated and their combined current considered. Three-phase devices below 63 A are delivered with a cable but without a plug.
The datasheet specifies cooling water intake temperature of 5–20 °C. Cooling power drops as cooling water temperature rises above the 15 °C reference, and flow rate may need to increase. The cooling water circuit contains copper, stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM, so only compatible water may be used.
The manual directs shutting off the cooling water supply even for short downtimes such as overnight to prevent water damage and unnecessary load on the cooling water circuit. Hoses and connections must be periodically checked for leaks and quality and replaced as needed. Refrigerant-circuit work must be performed by approved refrigeration/air-conditioning contractors.
Selection & Integration Q&A
Choose the 620w when you need the largest water-cooled dynamic capacity in the series: 12 kW heating, -60 to 200 °C, 616 kg mass and 19.9 l expansion tank. The 510w and 520w have lower noise levels (60/61 dB(A)) but smaller capacity; select them for lower heat loads or tighter acoustic limits.
Provide cooling water at 5–20 °C inlet, max 6 bar pressure, 1 bar differential pressure, with G3/4 male connections. Consumption is 760 l/h at 15 °C water and 0 °C flow. Insulate pipes if below condensation point; use only water compatible with copper, 1.4401, MS, PA, PPE, PTFE and EPDM.
Ambient must be 5–40 °C, IP20 dry indoor, outside ATEX zones. Transport upright only and allow ~2 h acclimation after temperature changes before power-on. A drip tray is required below the unit. Medical-device and direct-food applications are not permissible.
The base delivery excludes a mains plug for three-phase units below 63 A, hoses and fittings for M38x1.5 pump and G3/4 cooling water connections, and the drip tray. Heat transfer fluid (min 8.9 l) must be supplied separately. Periodic hose inspection and cooling water shutoff are operator tasks; refrigerant work requires certified contractors.