Peter Huber Kältemaschinenbau Unistat P527w Dynamisches — Temperature control units with Noise level 57 dB.
The Unistat P527w Dynamisches is a water-cooled, free-standing temperature control unit with a magnetically coupled stainless-steel pump and Pilot ONE controller, covering -55 to 250 °C with 12 kW heating. Its 'P' designation targets applications with high pressure drop, distinguishing it from standard 5xx siblings. It serves precise temperature control of externally closed or open circuits in industrial processes.
Peter Huber Kältemaschinenbau Unistat Series — Model Comparison & Selection
| Model | Noise level, dB | Display resolution | Heating capacity, W | Pump connection | Pump type | Temperature range, °C |
|---|---|---|---|---|---|---|
| Unistat P527w Dynamisches Current | 57 | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 510w Dynamisches | 60 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat 515w Dynamisches | — | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat 520w Dynamisches | 61 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 525 Dynamisches | 56 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 525w Dynamisches | 61 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 527w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 530w Dynamisches | 59 | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 540w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 545w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 610w Dynamisches | 62 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 615w Dynamisches | 62 | 0, 01 | 12000 | M30x1, 5 AG male | Pressure pump, variable | -60–200 |
| Unistat 620w Dynamisches | 68 | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 625w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 630w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 635w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 640w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 645w Dynamisches | — | 0, 01 | 36000 | flange DN32 PN10/40 EN10 | magnetically coupled, st | -60–200 |
| Unistat 650w Dynamisches | 73 | 0, 01 | 48000 | flange DN32 PN10/40 EN10 | magnetically coupled, st | -60–200 |
| Unistat 680w Dynamisches | — | 0, 01 | 96000 | DN50 PN16 (DIN EN 1092-1 | magnetically coupled, st | -60–200 |
| Unistat GL 530w Dynamisches | 61 | 0, 01 | 6000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 535w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 540w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 550w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 560w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 570w Dynamisches | — | 0, 01 | 48000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P530w Dynamisches | 61 | 0, 01 | 6000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P535w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P540w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P550w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P560w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P570w Dynamisches | — | 0, 01 | 48000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat P510 Dynamisches | 60 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat P510w Dynamisches | 60 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat P515w Dynamisches | — | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat P520 Dynamisches | — | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P520w Dynamisches | 61 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P525 Dynamisches | 56 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P525w Dynamisches | 61 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P530w Dynamisches | 62 | 0.01 | 12000 | M38x1,5 AG male | magnetically coupled, st | -55–250 |
| Unistat P540w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P545w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P610 Dynamisches | — | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P610w Dynamisches | 62 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P615 Dynamisches | — | 0, 01 | 12000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P615w Dynamisches | 62 | 0, 01 | 12000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P620w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P625w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P630w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P635w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P645w Dynamisches | — | 0, 01 | 36000 | flange DN32 PN10/40 EN10 | magnetically coupled, st | -60–200 |
| Unistat P650w Dynamisches | — | 0, 01 | 48000 | flange DN32 PN10/40 EN10 | magnetically coupled, st | -60–200 |
Full specifications
| Noise level | 57 dB(A) |
| Control output | POKO ONE |
| Heating capacity | 12 kW |
| Pump connection | M38x1, 5 AG male |
| Pump speed adjustable | Yes |
| Pump type | magnetically coupled, stainless steel |
| External sensor connection | Pt100 |
| Temperature range | -55...250 °C |
| Weight | 444 kg |
| Power supply | 400V 3~ 50Hz |
| Controller | Pilot ONE |
| Display resolution | 0, 01 K |
| Digital interface | Ethernet, USB (Host u. Device), RS232 |
| Maximum viscosity | 100 mm²/s |
| Ambient temperature limit | 5...40 °C |
| Cooling water connection | G3/4 male |
| Cooling water consumption | 880 l/h (at 15°C, flow 0°C) |
| Cooling water differential pressure | 1 bar |
| Cooling Water Pressure | 6 bar |
| Protection rating | IP20 |
| Safety class | III / FL |
Description
Construction and series positioning
- Free-standing Unistat 5xx platform with water-cooled refrigerant circuit (R-452A, 2.9 kg, 6.2 t CO2e) and 444 kg mass.
- 'P' suffix denotes a modification for applications with high pressure drop; 'w' denotes water cooling. Sibling models 510w, 515w, 520w and 525 Dynamisches differ in cooling capacity and noise level (56–61 dB(A)); this model is rated 57 dB(A).
- Pump: magnetically coupled, stainless steel, speed-adjustable, max. delivery 201 l/min, max. delivery pressure 5.3 bar, 42 l/min at 5.0 bar.
- Heating capacity 12 kW; temperature range -55…250 °C; display resolution 0.01 K; controller Pilot ONE with POKO ONE control output.
Behavior under load and media
- Cooling capacity with ethanol falls from 12 kW at 0 °C to 6 kW at -20 °C, 2 kW at -40 °C and 1 kW at -50 °C, so low-temperature duty must be checked against the actual heat load.
- Heat transfer fluid must not exceed 100 mm²/s kinematic viscosity; minimum filling capacity 8.2 l, expansion tank 19.9 l.
- Safety class III / FL permits flammable fluids with fire point ≥65 °C; ethanol use requires supervised operation.
- Process Safety mode releases maximum cooling at the OT trigger instead of switching off all poles, and requires the compressor set to Permanently ON.
Installation, connection and control
- Power: 400 V 3~ 50 Hz, max. current 31.62 A, fuse 3x32 A; delivered with cable but without plug for three-phase devices below 63 A.
- Voltage tolerance ±5% only with simultaneous frequency tolerance ±2%; opposite-sign deviations are not allowed.
- Cooling water: G3/4 male connection, 880 l/h at 15 °C water/0 °C flow, differential pressure 1–4 bar, max. pressure 6 bar; inlet temperature 5–20 °C; insulate pipes below dew point.
- Interfaces: Ethernet, USB host and device, RS232; external Pt100 sensor connection; IP20; ambient 5–40 °C.
- Expansion vessel must remain unlocked for externally closed applications and locked for externally open (bath) applications.
Integration & Operating Notes
The unit draws up to 31.62 A and requires a 3x32 A fuse; three-phase devices below 63 A are delivered with cable but without a plug, so the customer must provide the plug and connection. Voltage tolerance is ±5% only with simultaneous frequency tolerance ±2%, and opposite-sign deviations are not allowed.
The cooling water circuit requires 880 l/h at 15 °C water and 0 °C flow, with minimum differential pressure 1 bar and maximum 4 bar, and absolute pressure not exceeding 6 bar. Inlet temperature must be between 5 °C and 20 °C; if water can fall below the dew point, pipes must be insulated to prevent condensation.
The maximum permissible kinematic viscosity of the heat transfer fluid is 100 mm²/s. At low temperatures viscosity rises, so fluid selection must ensure this limit is not exceeded at the lowest operating temperature; otherwise circulation and heat transfer degrade.
In Process Safety mode, when the set overtemperature trigger value is reached, the controller releases maximum cooling capacity instead of switching off all poles. This mode requires the compressor to be set to Permanently ON; otherwise the protective cooling function is not available.
The cooling water supply should be shut off even for short downtimes such as overnight to prevent water damage and unnecessary load on the cooling water circuit. Hoses and connections must be periodically checked for leaks and quality and replaced as needed.
Selection & Integration Q&A
Choose the P527w when the external circuit has high pressure drop and water cooling is available; the 'P' modification is designed for high pressure drop. The 525 Dynamisches is air-cooled and quieter (56 dB(A)), while the 520w is water-cooled with 61 dB(A). Select based on cooling capacity, pressure drop and cooling water availability.
Cooling water: G3/4 male, 880 l/h at 15 °C water/0 °C flow, differential pressure 1–4 bar, max. pressure 6 bar, inlet 5–20 °C. Electrical: 400 V 3~ 50 Hz, max. 31.62 A, 3x32 A fuse; cable supplied but no plug, so provide a suitable plug and connection.
Install upright and empty, with leveling feet activated and parking brakes engaged. Ambient temperature 5–40 °C, IP20, not in ATEX zones. Allow 2 h acclimation after temperature changes. Cooling water inlet 5–20 °C; insulate pipes if below dew point.
Periodically check hoses and connections for leaks and quality; shut off cooling water during downtimes. The plug for the power cable is not included. A drip tray for condensation/fluid must be installed by the responsible body. Refrigerant work requires approved contractors.