Peter Huber Kältemaschinenbau Unistat GL 560w Dynamisches

Peter Huber Kältemaschinenbau Unistat GL 560w Dynamisches — Temperature control units.

The Unistat GL 560w Dynamisches is a water-cooled, CO2 (R-744) refrigerated circulating thermostat with a magnetically coupled stainless-steel pump, covering -50 to 200 °C with 24 kW heating. Within the Unistat 5xx series it is the GL/water-cooled modification, requiring a 400 V three-phase supply and a 1–4 bar cooling-water circuit.

Peter Huber Kältemaschinenbau Unistat Series — Model Comparison & Selection

Model Noise level, dBDisplay resolutionHeating capacity, WPump connectionPump typeTemperature range, °C
Unistat GL 560w Dynamisches Current —0, 0124000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat 510w Dynamisches 600, 016000M30x1, 5 AG malemagnetically coupled, st-50–250
Unistat 515w Dynamisches —0, 016000M30x1, 5 AG malemagnetically coupled, st-50–250
Unistat 520w Dynamisches 610, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat 525 Dynamisches 560, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat 525w Dynamisches 610, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat 527w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat 530w Dynamisches 590, 0112000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat 540w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat 545w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat 610w Dynamisches 620, 016000M30x1, 5 AG malemagnetically coupled, st-60–200
Unistat 615w Dynamisches 620, 0112000M30x1, 5 AG malePressure pump, variable -60–200
Unistat 620w Dynamisches 680, 0112000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat 625w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat 630w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat 635w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat 640w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat 645w Dynamisches —0, 0136000flange DN32 PN10/40 EN10magnetically coupled, st-60–200
Unistat 650w Dynamisches 730, 0148000flange DN32 PN10/40 EN10magnetically coupled, st-60–200
Unistat 680w Dynamisches —0, 0196000DN50 PN16 (DIN EN 1092-1magnetically coupled, st-60–200
Unistat GL 530w Dynamisches 610, 016000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL 535w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL 540w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL 550w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL 570w Dynamisches —0, 0148000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P530w Dynamisches 610, 016000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P535w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P540w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P550w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P560w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P570w Dynamisches —0, 0148000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat P510 Dynamisches 600, 016000M30x1, 5 AG malemagnetically coupled, st-50–250
Unistat P510w Dynamisches 600, 016000M30x1, 5 AG malemagnetically coupled, st-50–250
Unistat P515w Dynamisches —0, 016000M30x1, 5 AG malemagnetically coupled, st-50–250
Unistat P520 Dynamisches —0, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat P520w Dynamisches 610, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat P525 Dynamisches 560, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat P525w Dynamisches 610, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat P527w Dynamisches 570, 0112000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat P530w Dynamisches 620.0112000M38x1,5 AG malemagnetically coupled, st-55–250
Unistat P540w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat P545w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat P610 Dynamisches —0, 016000M30x1, 5 AG malemagnetically coupled, st-60–200
Unistat P610w Dynamisches 620, 016000M30x1, 5 AG malemagnetically coupled, st-60–200
Unistat P615 Dynamisches —0, 0112000M30x1, 5 AG malemagnetically coupled, st-60–200
Unistat P615w Dynamisches 620, 0112000M30x1, 5 AG malemagnetically coupled, st-60–200
Unistat P620w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat P625w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat P630w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat P635w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat P645w Dynamisches —0, 0136000flange DN32 PN10/40 EN10magnetically coupled, st-60–200
Unistat P650w Dynamisches —0, 0148000flange DN32 PN10/40 EN10magnetically coupled, st-60–200

Full specifications

Core Performance & Functional Specifications
Control output POKO ONE
Heating capacity 24 kW
Pump connection M38x1, 5 AG male
Pump speed adjustable Yes
Pump type magnetically coupled, stainless steel
External sensor connection Pt100
Temperature range -50...200 °C
Electrical, Power & Drive Specifications
Power supply 400V 3~ 50Hz
Interfaces, Connections & Control
Controller Pilot ONE
Display resolution 0, 01 K
Digital interface Ethernet, USB (Host u. Device), RS232
Materials, Media & Process Compatibility
Maximum viscosity 100 mm²/s
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C
Cooling water connection G3/4 male
Cooling water differential pressure 1 bar (min)
Cooling Water Pressure 6 bar (max)
Protection rating IP20
Standards, Safety & General Data
Safety class III / FL

Description

Construction and series positioning

Working range and media

Installation and operation

Integration & Operating Notes

Cooling & Media
Cooling water must be 1–4 bar differential, max 6 bar

The building water system must deliver at least 1 bar and no more than 4 bar differential pressure across the cooling-water circuit, with static pressure never exceeding 6 bar. Below 1 bar the rated cooling capacity is not reached; above 6 bar the internal circuit can be damaged. Rated performance is quoted only at 15 °C inlet and 1 bar differential.

Unistat GL 560w Technical Data, page 2
Electrical
Three-phase supply needs a site-provided plug

The unit requires 400 V 3~ 50 Hz and is delivered with a cable but without a plug because three-phase devices below 63 A ship that way. The electrical installer must provide a matching plug and verify that voltage stays within ±5% while frequency stays within ±2%; certain tolerance combinations are not permitted.

Unistat GL 560w Technical Data, page 2
Mounting
Expansion vessel must stay unlocked for closed loops

For an externally closed application the expansion vessel must remain unlocked; locking it causes overpressure damage to the application. For an externally open (bath) application the vessel must be locked to prevent fluid loss. The installation must also include a condensation-water/heat-transfer-fluid drip tray below the unit.

Unistat Operation Manual, Commissioning / page 33
Process Limits
Fluid viscosity capped at 100 mm²/s

Heat transfer fluid with kinematic viscosity above 100 mm²/s overloads the magnetically coupled pump and degrades circulation. Because the unit is FL-rated, the fluid must also have a fire point of at least 65 °C, and ethanol may only be used under supervised operation.

Unistat GL 560w Technical Data, page 1; Unistat Operation Manual, Section 1.7
Control & I/O
Process Safety needs compressor set to Permanently ON

In Process Safety mode the controller releases maximum cooling capacity at the overtemperature trigger instead of switching off all poles. This mode only works if the compressor is configured to Permanently ON; otherwise the protective cooling action is not available during exothermic events.

Unistat Operation Manual, Setup Mode / page 19
Maintenance
Shut off cooling water even for overnight stops

The cooling-water supply should be closed for any downtime, including overnight, to avoid water damage and unnecessary load on the circuit. Hoses and hose connections must be checked periodically for leaks and quality and replaced as required; refrigerant-circuit work is restricted to approved refrigeration contractors.

Unistat Operation Manual, page 29; Section 1.4.2

Selection & Integration Q&A

When should I choose the GL 560w over the air-cooled or non-GL Unistat 5xx siblings?

Pick the GL 560w when a cooling-water supply is available and CO2 refrigerant (R-744, GWP 1) is preferred for environmental compliance. Air-cooled siblings need no water but reject heat to the room; choose them only where water is unavailable and room heat load is acceptable.

What must the site provide for the cooling-water and process connections?

A G3/4 male cooling-water connection fed at 1–4 bar differential (max 6 bar, intake 5–20 °C) with water compatible with copper, 1.4401 stainless, PA, PPE, PTFE and EPDM. The process side uses the M38x1.5 male pump connection, so matching hoses and fittings must be ordered separately.

What installation environment and duty limits apply from the manual?

Install indoors at 5–40 °C ambient, IP20, never inside an ATEX zone. Transport and store upright only, move only when emptied, and let the unit acclimate about 2 hours after a cold-to-warm move before power-on. Leveling feet or caster brakes must be set before commissioning.

What maintenance and delivery items are not included with the base unit?

The three-phase plug is not included (cable only). A drip tray below the unit is the operator's responsibility. Periodic tasks include checking hoses for leaks and quality, cleaning the dirt trap and liquefier fins, and replacing heat transfer fluid; refrigerant work requires approved contractors.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Unistat GL 560w Technical Data