No photo available yet

Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau Unistat P645w Dynamisches

Peter Huber Kältemaschinenbau Unistat P645w Dynamisches — Temperature control units.

The Unistat P645w Dynamisches is a water-cooled, free-standing temperature control unit with a magnetically coupled stainless-steel pump, covering -60 to 200 °C with 36 kW heating capacity. It is the high-capacity water-cooled variant of the Unistat 6xx series, distinguished by DN32 PN10/40 process and cooling-water flanges and a 70 A / 460 V 3~ 60 Hz supply. It serves closed-loop temperature control of large externally closed applications requiring high heating power and dynamic performance.

Peter Huber Kältemaschinenbau Unistat Series — Model Comparison & Selection

Model Noise level, dBDisplay resolutionHeating capacity, WPump connectionPump typeTemperature range, °C
Unistat P645w Dynamisches Current —0, 0136000flange DN32 PN10/40 EN10magnetically coupled, st-60–200
Unistat 510w Dynamisches 600, 016000M30x1, 5 AG malemagnetically coupled, st-50–250
Unistat 515w Dynamisches —0, 016000M30x1, 5 AG malemagnetically coupled, st-50–250
Unistat 520w Dynamisches 610, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat 525 Dynamisches 560, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat 525w Dynamisches 610, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat 527w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat 530w Dynamisches 590, 0112000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat 540w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat 545w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat 610w Dynamisches 620, 016000M30x1, 5 AG malemagnetically coupled, st-60–200
Unistat 615w Dynamisches 620, 0112000M30x1, 5 AG malePressure pump, variable -60–200
Unistat 620w Dynamisches 680, 0112000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat 625w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat 630w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat 635w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat 640w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat 645w Dynamisches —0, 0136000flange DN32 PN10/40 EN10magnetically coupled, st-60–200
Unistat 650w Dynamisches 730, 0148000flange DN32 PN10/40 EN10magnetically coupled, st-60–200
Unistat 680w Dynamisches —0, 0196000DN50 PN16 (DIN EN 1092-1magnetically coupled, st-60–200
Unistat GL 530w Dynamisches 610, 016000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL 535w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL 540w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL 550w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL 560w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL 570w Dynamisches —0, 0148000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P530w Dynamisches 610, 016000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P535w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P540w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P550w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P560w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P570w Dynamisches —0, 0148000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat P510 Dynamisches 600, 016000M30x1, 5 AG malemagnetically coupled, st-50–250
Unistat P510w Dynamisches 600, 016000M30x1, 5 AG malemagnetically coupled, st-50–250
Unistat P515w Dynamisches —0, 016000M30x1, 5 AG malemagnetically coupled, st-50–250
Unistat P520 Dynamisches —0, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat P520w Dynamisches 610, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat P525 Dynamisches 560, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat P525w Dynamisches 610, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat P527w Dynamisches 570, 0112000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat P530w Dynamisches 620.0112000M38x1,5 AG malemagnetically coupled, st-55–250
Unistat P540w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat P545w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat P610 Dynamisches —0, 016000M30x1, 5 AG malemagnetically coupled, st-60–200
Unistat P610w Dynamisches 620, 016000M30x1, 5 AG malemagnetically coupled, st-60–200
Unistat P615 Dynamisches —0, 0112000M30x1, 5 AG malemagnetically coupled, st-60–200
Unistat P615w Dynamisches 620, 0112000M30x1, 5 AG malemagnetically coupled, st-60–200
Unistat P620w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat P625w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat P630w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat P635w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat P650w Dynamisches —0, 0148000flange DN32 PN10/40 EN10magnetically coupled, st-60–200

Full specifications

Core Performance & Functional Specifications
Control output POKO ONE (potential-free contact)
Expansion volume 30 l
Filling volume 30 l (min)
Heating capacity 36 kW
Pump connection flange DN32 PN10/40 EN1092-1
Pump speed adjustable Yes
Pump type magnetically coupled, stainless steel
External sensor connection Pt100
Temperature range -60...200 °C
Dimensions, Weight & Mechanical Design
Weight 2150 kg (net)
Electrical, Power & Drive Specifications
Current consumption 70 A (max)
Power supply 460V 3~ 60Hz
Interfaces, Connections & Control
Controller Pilot ONE
Display resolution 0, 01 K
Digital interface Ethernet, USB (Host u. Device), RS232
Materials, Media & Process Compatibility
Maximum viscosity 50 mm²/s (max permissible)
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C (permissible)
Cooling water connection flange DN32 PN10/40 EN1092-1
Cooling water consumption 6000 l/h (at 15°C, flow 0°C)
Cooling water differential pressure 3 bar (min)
Cooling Water Pressure 6 bar (max)
Protection rating IP20
Standards, Safety & General Data
Safety class III / FL

Description

Construction and series positioning

Behavior under load and media

Installation, connection and control

Integration & Operating Notes

Electrical
Branch protection and cabling must be engineered on site

The 70 A maximum current and >3.5 mA leakage current require external UL 489 branch-circuit protection, and because current exceeds 63 A the unit ships without cable and plug. The installer must size conductors, fuses (3×80 A) and the disconnect means before the unit can be energised.

Unistat P645w Technical Data, page 2
Cooling & Media
Cooling-water pressure window is narrow and flow is high

The cooling circuit needs at least 3 bar differential pressure but must not exceed 6 bar, while consuming 6000 l/h at 15 °C. Supply pressure below 3 bar will starve the condenser; above 6 bar the plate heat exchanger and connections are at risk. Intake temperature must stay between 5 and 20 °C.

Unistat P645w Technical Data, page 2
Process Limits
Expansion vessel lock state depends on open or closed application

For an externally closed circuit the expansion vessel must remain unlocked; locking it causes overpressure damage to the application. For an externally open bath the vessel must be locked to prevent fluid loss. Verify the isolating sleeve or shut-off valve position before filling and venting.

Unistat Operation Manual, Commissioning / page 33
Control & I/O
Process Safety needs the compressor set to Permanently ON

In Process Safety mode the controller releases maximum cooling capacity at the overtemperature trigger rather than switching off all poles. This behaviour depends on the compressor being configured to Permanently ON; otherwise the safety response will not deliver the intended heat extraction under exothermic conditions.

Unistat Operation Manual, Setup Mode / page 19
Mounting
Acclimation and upright transport are mandatory before power-on

The unit must be transported and stored upright only, and moved only when emptied. After moving between cold and warm environments, allow about 2 hours acclimation before switching on to avoid condensation-induced electrical faults. Leveling feet must be activated and caster brakes engaged before commissioning.

Unistat Operation Manual, Commissioning / pages 22, 29
Maintenance
Cooling water must be shut off during short downtimes

Shut off the cooling-water supply even for overnight downtime to avoid unnecessary load and water damage. Hoses and hose connections must be checked periodically for leaks and quality and replaced as required; the hat-type strainer/dirt trap requires draining the cooling circuit before dismantling.

Unistat Operation Manual, Service and Maintenance / page 29

Selection & Integration Q&A

When should I choose the P645w Dynamisches instead of a smaller Unistat 5xxw Dynamisches sibling?

Pick the P645w when the application needs 36 kW heating, a 70 A 460 V 3~ supply and DN32 PN10/40 flanges for high flow. The 510w/515w/520w/525 siblings are lower-capacity units; choose them when the heating load and cooling-water flow (6000 l/h here) cannot be supported on site.

What adjacent infrastructure must be ready before the P645w can be commissioned?

A 460 V 3~ 60 Hz supply with 3×80 A fuses and UL 489 branch protection, on-site power cabling (no cable/plug supplied above 63 A), a cooling-water supply of 3–6 bar differential at 6000 l/h and 5–20 °C, and mating DN32 PN10/40 EN1092-1 flanges with DIN 3863 ball sockets and DIN 3870 sleeve nuts.

What site and duty-cycle limits apply to installing the P645w?

Install only outside ATEX zones, indoors in a dry IP20-protected location, ambient 5–40 °C, on a level floor with a drip tray where required. Transport upright and emptied, allow 2 h acclimation after temperature changes, and shut off cooling water during overnight downtime.

What maintenance and consumables are not included in the base delivery?

The base unit ships without power cable and plug, without heat transfer fluid, and without the optional gas detection sensor or processing unit. Periodic tasks include hose and connection inspection/replacement, cleaning the liquefier fins and hat-type strainer, and heat transfer fluid inspection/replacement with circuit rinsing.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Unistat P645w Technical Data
Datasheet ·139,2 КБ ·2 pp.
View PDF
PDF
Unistat® Operation Manual — Unistat® 5, Unistat® Pilot ONE®
Manual ·3,6 МБ ·100 pp.
View PDF
PDF
Unistat Operation Manual
Manual ·3,7 МБ ·102 pp.
View PDF