Peter Huber Kältemaschinenbau Unistat GL P535w Dynamisches
Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau Unistat GL P535w Dynamisches

Peter Huber Kältemaschinenbau Unistat GL P535w Dynamisches — Temperature control units.

The Unistat GL P535w Dynamisches is a water-cooled, CO2 (R-744) refrigerant, high-pressure-drop free-standing temperature control unit rated -50 to 200 °C with 12 kW heating and a magnetically coupled stainless-steel pump. It is the GL/P/w modification of the Unistat 5xx series, distinguished by CO2 refrigerant, high-pressure-drop process suitability and water cooling. It serves precise temperature control of externally closed or open applications via the Pilot ONE controller.

Peter Huber Kältemaschinenbau Unistat Series — Model Comparison & Selection

Model Noise level, dBDisplay resolutionHeating capacity, WPump connectionPump typeTemperature range, °C
Unistat GL P535w Dynamisches Current —0, 0112000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat 510w Dynamisches 600, 016000M30x1, 5 AG malemagnetically coupled, st-50–250
Unistat 515w Dynamisches —0, 016000M30x1, 5 AG malemagnetically coupled, st-50–250
Unistat 520w Dynamisches 610, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat 525 Dynamisches 560, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat 525w Dynamisches 610, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat 527w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat 530w Dynamisches 590, 0112000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat 540w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat 545w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat 610w Dynamisches 620, 016000M30x1, 5 AG malemagnetically coupled, st-60–200
Unistat 615w Dynamisches 620, 0112000M30x1, 5 AG malePressure pump, variable -60–200
Unistat 620w Dynamisches 680, 0112000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat 625w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat 630w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat 635w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat 640w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat 645w Dynamisches —0, 0136000flange DN32 PN10/40 EN10magnetically coupled, st-60–200
Unistat 650w Dynamisches 730, 0148000flange DN32 PN10/40 EN10magnetically coupled, st-60–200
Unistat 680w Dynamisches —0, 0196000DN50 PN16 (DIN EN 1092-1magnetically coupled, st-60–200
Unistat GL 530w Dynamisches 610, 016000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL 535w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL 540w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL 550w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL 560w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL 570w Dynamisches —0, 0148000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P530w Dynamisches 610, 016000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P540w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P550w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P560w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P570w Dynamisches —0, 0148000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat P510 Dynamisches 600, 016000M30x1, 5 AG malemagnetically coupled, st-50–250
Unistat P510w Dynamisches 600, 016000M30x1, 5 AG malemagnetically coupled, st-50–250
Unistat P515w Dynamisches —0, 016000M30x1, 5 AG malemagnetically coupled, st-50–250
Unistat P520 Dynamisches —0, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat P520w Dynamisches 610, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat P525 Dynamisches 560, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat P525w Dynamisches 610, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat P527w Dynamisches 570, 0112000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat P530w Dynamisches 620.0112000M38x1,5 AG malemagnetically coupled, st-55–250
Unistat P540w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat P545w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat P610 Dynamisches —0, 016000M30x1, 5 AG malemagnetically coupled, st-60–200
Unistat P610w Dynamisches 620, 016000M30x1, 5 AG malemagnetically coupled, st-60–200
Unistat P615 Dynamisches —0, 0112000M30x1, 5 AG malemagnetically coupled, st-60–200
Unistat P615w Dynamisches 620, 0112000M30x1, 5 AG malemagnetically coupled, st-60–200
Unistat P620w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat P625w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat P630w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat P635w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat P645w Dynamisches —0, 0136000flange DN32 PN10/40 EN10magnetically coupled, st-60–200
Unistat P650w Dynamisches —0, 0148000flange DN32 PN10/40 EN10magnetically coupled, st-60–200

Full specifications

Core Performance & Functional Specifications
Control output POKO ONE
Heating capacity 12 kW
Pump connection M38x1, 5 AG male
Pump speed adjustable Yes
Pump type magnetically coupled, stainless steel
External sensor connection Pt100
Temperature range -50...200 °C
Dimensions, Weight & Mechanical Design
Weight 600 kg
Electrical, Power & Drive Specifications
Power supply 400V 3~ 50Hz
Interfaces, Connections & Control
Controller Pilot ONE
Display resolution 0, 01 K
Digital interface Ethernet, USB (Host u. Device), RS232
Materials, Media & Process Compatibility
Maximum viscosity 100 mm²/s
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C
Cooling water connection G3/4 male
Cooling water consumption 2100 l/h (at 15°C, flow 0°C)
Cooling water differential pressure 1 bar
Cooling Water Pressure 6 bar
Protection rating IP20
Standards, Safety & General Data
Safety class III / FL

Description

Construction and series positioning

Working range and behavior

Control, installation and operation

Integration & Operating Notes

Mounting
Install only outside ATEX zones and on a drip tray

The unit must not be installed or started within an ATEX zone; explosion protection requires a separate Ex px cabinet. The responsible body must install a condensation-water/heat-transfer-fluid drip tray below the unit, and local legislation may prescribe it. Plan floor loading for 600 kg and access routes for 730×804×1738 mm.

Operation Manual, Section 1.3.3 / page 15-16; Section 1.4 / page 17
Electrical
Provide a 400 V three-phase supply with cable but no plug

The unit requires 400 V 3~ 50 Hz. Three-phase devices with current consumption below 63 A are supplied with cable but without a plug, so the installer must provide a suitable connection. Voltage tolerance ±5% and frequency tolerance ±2% must not be combined in opposite directions. Hard-wired connection must be carried out by an electrician.

Datasheet, page 2; Operation Manual, page 37
Cooling & Media
Keep cooling water within 5–20 °C and 1–4 bar differential

Cooling water inlet must be 5–20 °C with 1–4 bar differential pressure and no more than 6 bar pressure; consumption is 2100 l/h at 15 °C and flow 0 °C. Higher cooling-water temperature reduces cooling power and may require higher flow. If cooling water can fall below the dew point, insulate the internal cooling-water pipes. Shut off cooling water even for short downtimes such as overnight.

Datasheet, page 2; Operation Manual, page 29
Process Limits
Match expansion vessel state to open or closed application

For externally closed applications the expansion vessel must remain unlocked; locking it causes overpressure damage. For externally open (bath) applications the expansion vessel must be locked to prevent fluid loss. Heat transfer fluid viscosity must not exceed 100 mm²/s; FL-rated fluids require fire point ≥65 °C and ethanol only under supervision.

Operation Manual, page 33; Section 1.7 / page 19
Control & I/O
Set compressor to Permanently ON for Process Safety mode

In Process Safety mode the controller releases maximum cooling capacity at the overtemperature trigger instead of switching off all poles; this mode requires the compressor to be set to Permanently ON. Choose power-interruption behavior via Pilot ONE: Off/Standby (manual restart) or ON/Temperature control active (automatic restart, with a few-second INFO window to disable).

Operation Manual, Section 1.7.2 / page 20; Section 1.8.1 / page 21
Maintenance
Inspect hoses and clean strainer and liquefier fins periodically

Check periodically for leaks and quality of hoses and hose connections and replace as required. Maintenance scope includes cleaning liquefier fins, cleaning the hat-type strainer/dirt trap (with draining the cooling circuit and dismantling the cooling water supply), emptying the drip tray, function test of the emergency stop switch, and heat transfer fluid inspection/replacement with circuit rinsing. Work on the coolant circuit must be done by approved refrigeration/air-conditioning contractors.

Operation Manual, Maintenance section; Section 1.4.2 / page 19

Selection & Integration Q&A

When should I choose the Unistat GL P535w Dynamisches instead of the 510w, 515w, 520w or 525 Dynamisches siblings?

Choose the GL P535w when the process has high pressure drop (P), requires CO2 refrigerant (GL) and water cooling (w). The 510w/515w/520w are water-cooled without the P/GL designation; the 525 Dynamisches is a different modification. Confirm the process pressure drop and refrigerant preference before selecting.

What cooling-water supply and fittings must be provided for this unit?

Provide cooling water at 5–20 °C inlet, 1–4 bar differential pressure, max 6 bar, with G3/4 male connection; consumption is 2100 l/h at 15 °C and flow 0 °C. The circuit contains copper, 1.4401 stainless steel, MS, PA, PPE, PTFE and EPDM, so only compatible water may be used. Insulate internal pipes if water can fall below dew point.

What are the installation environment and duty-cycle limits from the manual?

Ambient must stay 5–40 °C; IP20; EMC class A group 1. Do not install in an ATEX zone. Transport and store upright only; allow about 2 hours acclimation when moving between cold and warm environments before power-on. Leveling feet must be activated and parking brakes engaged before commissioning.

What maintenance and consumables are required, and what is not included in base delivery?

Periodically check hoses and connections for leaks and quality and replace as needed; clean liquefier fins and the hat-type strainer/dirt trap; inspect/replace heat transfer fluid and rinse the circuit; test the emergency stop switch. The three-phase cable is supplied without a plug; pump fittings (M38×1.5 male, DIN 3863 ball socket and sleeve nut) and a drip tray are not included and must be provided.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Unistat GL P535w Temperature Control System Datasheet
Datasheet ·98,5 КБ ·2 pp.
View PDF
PDF
Unistat® Operation Manual — Unistat® 5, Unistat® Pilot ONE®
Manual ·3,6 МБ ·100 pp.
View PDF
PDF
Unistat Operation Manual
Manual ·3,7 МБ ·102 pp.
View PDF