Peter Huber Kältemaschinenbau Unistat 615w Dynamisches
Peter Huber Kältemaschinenbau Unistat 615w Dynamisches — Temperature control units with Noise level 62 dB.
The Unistat 615w Dynamisches is a water-cooled, free-standing temperature control unit with a -60 to 200 °C range, 12 kW heating and a variable-speed magnetically coupled pressure pump. It is the 6xx-series water-cooled modification, distinguished from air-cooled siblings by its cooling-water circuit and higher capacity. It serves precise external closed and open temperature control loops in process engineering.
Peter Huber Kältemaschinenbau Unistat Series — Model Comparison & Selection
| Model | Noise level, dB | Display resolution | Heating capacity, W | Pump connection | Pump type | Temperature range, °C |
|---|---|---|---|---|---|---|
| Unistat 615w Dynamisches Current | 62 | 0, 01 | 12000 | M30x1, 5 AG male | Pressure pump, variable | -60–200 |
| Unistat 510w Dynamisches | 60 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat 515w Dynamisches | — | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat 520w Dynamisches | 61 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 525 Dynamisches | 56 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 525w Dynamisches | 61 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 527w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 530w Dynamisches | 59 | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 540w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 545w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 610w Dynamisches | 62 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 620w Dynamisches | 68 | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 625w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 630w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 635w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 640w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 645w Dynamisches | — | 0, 01 | 36000 | flange DN32 PN10/40 EN10 | magnetically coupled, st | -60–200 |
| Unistat 650w Dynamisches | 73 | 0, 01 | 48000 | flange DN32 PN10/40 EN10 | magnetically coupled, st | -60–200 |
| Unistat 680w Dynamisches | — | 0, 01 | 96000 | DN50 PN16 (DIN EN 1092-1 | magnetically coupled, st | -60–200 |
| Unistat GL 530w Dynamisches | 61 | 0, 01 | 6000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 535w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 540w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 550w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 560w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 570w Dynamisches | — | 0, 01 | 48000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P530w Dynamisches | 61 | 0, 01 | 6000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P535w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P540w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P550w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P560w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P570w Dynamisches | — | 0, 01 | 48000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat P510 Dynamisches | 60 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat P510w Dynamisches | 60 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat P515w Dynamisches | — | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat P520 Dynamisches | — | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P520w Dynamisches | 61 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P525 Dynamisches | 56 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P525w Dynamisches | 61 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P527w Dynamisches | 57 | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P530w Dynamisches | 62 | 0.01 | 12000 | M38x1,5 AG male | magnetically coupled, st | -55–250 |
| Unistat P540w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P545w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P610 Dynamisches | — | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P610w Dynamisches | 62 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P615 Dynamisches | — | 0, 01 | 12000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P615w Dynamisches | 62 | 0, 01 | 12000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P620w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P625w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P630w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P635w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P645w Dynamisches | — | 0, 01 | 36000 | flange DN32 PN10/40 EN10 | magnetically coupled, st | -60–200 |
| Unistat P650w Dynamisches | — | 0, 01 | 48000 | flange DN32 PN10/40 EN10 | magnetically coupled, st | -60–200 |
Full specifications
| Noise level | 62 dB(A) (sound pressure level) |
| Control output | POKO ONE (potential-free contact) |
| Expansion volume | 26 l |
| Heating capacity | 12 kW |
| Pump connection | M30x1, 5 AG male |
| Pump speed adjustable | Yes |
| Pump type | Pressure pump, variable speed, magnetically coupled |
| External sensor connection | Pt100 |
| Temperature range | -60...200 °C |
| Weight | 367 kg (net) |
| Current consumption | 25 A (max) |
| Power supply | 400V 3~ 50Hz |
| Controller | Pilot ONE |
| Display resolution | 0, 01 K |
| Digital interface | Ethernet, USB (Host u. Device), RS232 |
| Maximum viscosity | 50 mm²/s (max permissible) |
| Ambient temperature limit | 5...40 °C (permissible) |
| Cooling water connection | G1/2 male |
| Cooling water differential pressure | 1 bar (min) |
| Cooling Water Pressure | 6 bar (max) |
| Protection rating | IP20 |
| Safety class | III / FL |
Description
Construction and series positioning
- Free-standing water-cooled unit (suffix 'w') with overall dimensions 630x704x1520 mm and 367 kg net weight; requires rigging and floor-loading checks.
- Refrigerant R-452A (GWP 2141, 2.55 kg charge, 5.5 t CO2 equivalent) in a water-cooled condenser; cooling water connection G1/2 male.
- Sits above the 510w/515w/520w water-cooled siblings in capacity; the 525 Dynamisches is air-cooled (no 'w') and quieter at 56 dB(A) versus 62 dB(A) here.
- Controller Pilot ONE with POKO ONE potential-free contact; interfaces Ethernet, USB host/device and RS232; external Pt100 sensor input.
Behavior under load and media
- Temperature range -60...200 °C with 0.01 K display resolution; cooling power 9.5 kW with Thermooil from 20 to 200 °C but only 1.2 kW with ethanol at -60 °C, so low-temperature duty must be checked against process load.
- Pump delivers max. 82 l/min and max. 1.5 bar, with 47 l/min at 1.0 bar; external loop pressure drop must be matched to this curve.
- Maximum permissible kinematic viscosity 50 mm²/s limits heat transfer fluid selection at low temperatures.
- Minimum filling capacity 6.5 l; expansion tank 26 l.
- Safety classification III/FL per DIN 12876 with adjustable overtemperature protection; FL-rated fluids require fire point ≥65 °C and ethanol only under supervision.
Installation, connection and control
- Requires 400 V 3~ 50 Hz supply, max. 25 A, 3x32 A fusing; three-phase units below 63 A are supplied with cable but without plug, so a plug and connection must be provided on site.
- Voltage tolerance ±5% with simultaneous frequency tolerance ±2%; a -5% voltage with +2% frequency is explicitly not allowed.
- Cooling water 5–20 °C, min. 1 bar differential pressure, max. 6 bar; consumption about 580 l/h at 15 °C water and 20 °C flow.
- IP20, ambient 5–40 °C; must be installed indoors, dry, and not within an ATEX zone.
- Expansion vessel must remain unlocked for externally closed applications and locked for externally open (bath) applications; incorrect setting causes overpressure damage or fluid loss.
- Process Safety mode requires the compressor set to Permanently ON to keep cooling active at the OT trigger.
Integration & Operating Notes
The 400 V three-phase supply must be dedicated and protected at 3x32 A; the unit is delivered with cable but no plug, so the customer must provide a matching plug and breaker. Voltage tolerance is only ±5% with ±2% frequency, and a -5% voltage with +2% frequency is not permitted.
The water-cooled condenser requires a facility supply of 5–20 °C with at least 1 bar differential pressure and no more than 6 bar; flow is about 580 l/h at 15 °C water and 20 °C flow. Circuit materials include copper, stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM, so water quality must be compatible. Shut off cooling water even for overnight downtime.
Cooling power is 9.5 kW with Thermooil from 20 to 200 °C but only 1.2 kW with ethanol at -60 °C. Process heat loads at the cold end must be checked against this figure; the maximum permissible kinematic viscosity of 50 mm²/s further restricts fluid choice at low temperature.
The unit must be transported and stored upright only; horizontal transport damages the compressor. Only an emptied unit may be moved. Casters, if present, carry only 25% of total mass symmetrically and are not suitable for transport; use an industrial truck. Leveling feet must be activated and parking brakes engaged before commissioning.
For externally closed applications the expansion vessel must remain unlocked; locking it causes overpressure damage. For externally open (bath) applications it must be locked to prevent fluid loss. The wrong setting is a direct damage risk, not a preference.
When Process Safety is enabled, the controller releases maximum cooling capacity at the overtemperature trigger instead of switching off all poles; this mode requires the compressor to be set to Permanently ON. Power Failure Auto can resume temperature control automatically after an outage if it was active, which must be assessed for unattended operation.
Work on the coolant circuit must be carried out by approved refrigeration/air-conditioning system contractors; general maintenance personnel may not service the refrigerant circuit. Hoses and connections must be periodically checked for leaks and quality and replaced as needed. A condensation water / heat transfer fluid drip tray must be installed below the unit.
Selection & Integration Q&A
Choose the 615w when the process needs the higher heating capacity (12 kW) and the 6xx platform's larger expansion volume (26 l) and pump delivery (82 l/min, 1.5 bar). The 510w/515w/520w are lower-capacity water-cooled units; the 525 Dynamisches is air-cooled and quieter (56 dB(A)) but lacks a cooling-water circuit.
A dedicated 400 V 3~ 50 Hz supply with 3x32 A fusing and a matching plug (cable supplied, plug not). Cooling water at 5–20 °C, 1–6 bar differential, G1/2 male connection, about 580 l/h at 15 °C water and 20 °C flow. Voltage tolerance ±5% with ±2% frequency; -5% voltage with +2% frequency is not allowed.
Indoors only, IP20, ambient 5–40 °C, not within an ATEX zone. Transport and store upright and empty; allow about 2 h acclimation after a cold-to-warm move before power-on. Casters are not for transport. Shut off cooling water even overnight. Medical-device and direct-food use are not permissible.
The plug for the three-phase cable, the condensation water / heat transfer fluid drip tray, and any gas detection sensor or processing unit are not part of the base unit and must be engineered by the operating company. Refrigerant-circuit service requires approved refrigeration contractors; hoses and heat transfer fluid are wear items to be inspected and replaced periodically.