Peter Huber Kältemaschinenbau Unistat 630w Dynamisches
Peter Huber Kältemaschinenbau Unistat 630w Dynamisches — Temperature control units.
The Unistat 630w Dynamisches is a water-cooled, free-standing temperature control system with a -60 to 200 °C range and 24 kW heating capacity, positioned as the high-capacity member of the Unistat 5xx/6xx series. Its magnetically coupled stainless-steel pump and Pilot ONE controller support dynamic temperature control of externally closed circuits. It is intended for precise thermal conditioning of industrial processes requiring high heating power and deep cooling.
Peter Huber Kältemaschinenbau Unistat Series — Model Comparison & Selection
| Model | Noise level, dB | Display resolution | Heating capacity, W | Pump connection | Pump type | Temperature range, °C |
|---|---|---|---|---|---|---|
| Unistat 630w Dynamisches Current | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 510w Dynamisches | 60 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat 515w Dynamisches | — | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat 520w Dynamisches | 61 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 525 Dynamisches | 56 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 525w Dynamisches | 61 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 527w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 530w Dynamisches | 59 | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 540w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 545w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 610w Dynamisches | 62 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 615w Dynamisches | 62 | 0, 01 | 12000 | M30x1, 5 AG male | Pressure pump, variable | -60–200 |
| Unistat 620w Dynamisches | 68 | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 625w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 635w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 640w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 645w Dynamisches | — | 0, 01 | 36000 | flange DN32 PN10/40 EN10 | magnetically coupled, st | -60–200 |
| Unistat 650w Dynamisches | 73 | 0, 01 | 48000 | flange DN32 PN10/40 EN10 | magnetically coupled, st | -60–200 |
| Unistat 680w Dynamisches | — | 0, 01 | 96000 | DN50 PN16 (DIN EN 1092-1 | magnetically coupled, st | -60–200 |
| Unistat GL 530w Dynamisches | 61 | 0, 01 | 6000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 535w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 540w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 550w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 560w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 570w Dynamisches | — | 0, 01 | 48000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P530w Dynamisches | 61 | 0, 01 | 6000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P535w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P540w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P550w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P560w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P570w Dynamisches | — | 0, 01 | 48000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat P510 Dynamisches | 60 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat P510w Dynamisches | 60 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat P515w Dynamisches | — | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat P520 Dynamisches | — | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P520w Dynamisches | 61 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P525 Dynamisches | 56 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P525w Dynamisches | 61 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P527w Dynamisches | 57 | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P530w Dynamisches | 62 | 0.01 | 12000 | M38x1,5 AG male | magnetically coupled, st | -55–250 |
| Unistat P540w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P545w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P610 Dynamisches | — | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P610w Dynamisches | 62 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P615 Dynamisches | — | 0, 01 | 12000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P615w Dynamisches | 62 | 0, 01 | 12000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P620w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P625w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P630w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P635w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P645w Dynamisches | — | 0, 01 | 36000 | flange DN32 PN10/40 EN10 | magnetically coupled, st | -60–200 |
| Unistat P650w Dynamisches | — | 0, 01 | 48000 | flange DN32 PN10/40 EN10 | magnetically coupled, st | -60–200 |
Full specifications
| Control output | POKO ONE |
| Heating capacity | 24 kW |
| Pump connection | M38x1, 5 AG male |
| Pump speed adjustable | Yes |
| Pump type | magnetically coupled, stainless steel |
| External sensor connection | Pt100 |
| Temperature range | -60...200 °C |
| Weight | 715 kg |
| Power supply | 400V 3~ 50Hz |
| Controller | Pilot ONE |
| Display resolution | 0, 01 K |
| Digital interface | Ethernet, USB (Host u. Device), RS232 |
| Maximum viscosity | 100 mm²/s |
| Ambient temperature limit | 5...40 °C |
| Cooling water connection | G3/4 male |
| Cooling water differential pressure | 1 bar (min.) |
| Cooling Water Pressure | 6 bar (max.) |
| Protection rating | IP20 |
| Safety class | III / FL |
Description
Construction and series positioning
- The Unistat 630w Dynamisches is a water-cooled (w suffix) free-standing unit in the Unistat 5xx/6xx family, distinguished from air-cooled siblings by its water-cooled refrigerant circuit and from smaller models (510w, 515w, 520w, 525) by its 24 kW heating capacity and 715 kg mass.
- The pump is magnetically coupled and stainless steel, with a M38x1.5 male connection; pump speed is adjustable. The controller is Pilot ONE with POKO ONE control output, Ethernet, USB (host and device) and RS232 interfaces, plus a Pt100 external sensor input.
- The unit is IP20 and requires a 400 V 3~ 50 Hz supply with a maximum current of 48.7 A and 3x50 A fuses. It is delivered with a cable but without a plug (three-phase devices under 63 A).
Behavior under load and media
- The temperature range is -60 to 200 °C. Cooling power with ethanol falls from 21 kW at 0 °C to 2.5 kW at -60 °C, so usable capacity at the lowest temperatures is much lower than the heating capacity.
- The maximum permissible kinematic viscosity of the heat transfer fluid is 100 mm²/s, which limits fluid selection at low temperatures. The minimum filling capacity is 8.9 l and the expansion tank holds 19.9 l.
- Cooling water must be supplied at 1–4 bar differential pressure and no more than 6 bar static pressure, with G3/4 male connections. The unit is designed for cooling water intake between 5 °C and 20 °C; cooling power drops as cooling water temperature rises. If cooling water temperature can fall below the condensation point, the cooling water pipes in the unit must be insulated.
Installation, control and operation
- The unit must be installed indoors, outside ATEX zones, at 5–40 °C ambient temperature. It weighs 715 kg and measures 918x963x1771 mm, so floor loading and access routes must be planned. Leveling feet must be activated and parking brakes engaged before commissioning.
- The expansion vessel must remain unlocked for externally closed applications and locked for externally open (bath) applications. The cooling water supply should be shut off even for short downtimes such as overnight.
- The Pilot ONE controller supports process safety mode (requires compressor set to Permanently ON), power failure auto-resume, and overtemperature protection settings. The unit has a leakage current greater than 3.5 mA, requiring appropriate protective earthing and RCD selection. Voltage and frequency tolerances are ±5% and ±2%, but the combination of -5% voltage with +2% frequency is not allowed.
Integration & Operating Notes
The unit draws up to 48.7 A and is delivered with a cable but without a plug. The site must provide a suitable plug and protection devices rated for 3x50 A. Voltage and frequency tolerances are ±5% and ±2%, but the combination of -5% voltage with +2% frequency is not allowed. Leakage current exceeds 3.5 mA, so RCD selection and protective earthing must be engineered accordingly.
The cooling water circuit requires a differential pressure of 1–4 bar and a static pressure no higher than 6 bar, with G3/4 male connections. Cooling capacity drops as the cooling water intake temperature rises above 5 °C. If the cooling water can fall below the condensation point, the internal cooling water pipes must be insulated to prevent condensation and corrosion.
The magnetically coupled stainless-steel pump can handle fluids up to 100 mm²/s kinematic viscosity. At low temperatures, many fluids become too viscous and can overload the pump or reduce circulation. The minimum filling capacity is 8.9 l and the expansion tank holds 19.9 l; ensure the fluid volume and expansion volume match the application.
The unit weighs 715 kg and must be transported upright only. Casters are not for transport and carry only 25% of total mass symmetrically; use an industrial truck. Before operation, unscrew/activate leveling feet and engage parking brakes to prevent creeping. Allow about 2 hours acclimation when moving between cold and warm environments before power-on.
In Process Safety mode, when the overtemperature trigger value is reached, the controller releases maximum cooling capacity instead of switching off all poles. This mode requires the compressor to be set to Permanently ON. The power failure auto setting can resume temperature control automatically after a power outage if it was active; choose this behavior according to whether unattended restart is acceptable.
The cooling water supply should be shut off during short downtimes such as overnight to prevent water damage and unnecessary load on the circuit. Hoses and connections must be periodically checked for leaks and quality and replaced as needed. Work on the coolant circuit must be carried out by approved refrigeration/air-conditioning contractors.
Selection & Integration Q&A
Choose the 630w when you need 24 kW heating capacity and a -60 to 200 °C range with high cooling power (21 kW at 0 °C with ethanol). The 510w and 520w have lower capacities and are air-cooled; the 630w is water-cooled and weighs 715 kg, requiring cooling water supply and a 400 V 3~ 48.7 A supply.
Cooling water: G3/4 male connections, 1–4 bar differential pressure, max 6 bar static, intake 5–20 °C. Electrical: 400 V 3~ 50 Hz, max 48.7 A, 3x50 A fuses, cable delivered without plug. Leakage current >3.5 mA requires suitable RCD and earthing.
The base delivery includes a cable but no plug; a suitable 3x50 A plug must be provided on site. A drip tray for condensation water/heat transfer fluid must be installed by the responsible body. Cooling water hoses and fittings (ball sockets to DIN 3863, sleeve nuts to DIN 3870) are not included. Periodic checks of hoses and fluid replacement are required.