Peter Huber Kältemaschinenbau Unistat 625w Dynamisches
Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau Unistat 625w Dynamisches

Peter Huber Kältemaschinenbau Unistat 625w Dynamisches — Temperature control units.

The Unistat 625w Dynamisches is a water-cooled, free-standing temperature control unit with a magnetically coupled stainless-steel pump and Pilot ONE controller, covering -60 to 200 °C with 12 kW heating. Its water-cooled condenser requires 1–4 bar differential cooling water pressure and 5–20 °C intake, distinguishing it from air-cooled siblings. It serves dynamic process temperature control in externally closed or open circuits.

Peter Huber Kältemaschinenbau Unistat Series — Model Comparison & Selection

Model Noise level, dBDisplay resolutionHeating capacity, WPump connectionPump typeTemperature range, °C
Unistat 625w Dynamisches Current —0, 0112000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat 510w Dynamisches 600, 016000M30x1, 5 AG malemagnetically coupled, st-50–250
Unistat 515w Dynamisches —0, 016000M30x1, 5 AG malemagnetically coupled, st-50–250
Unistat 520w Dynamisches 610, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat 525 Dynamisches 560, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat 525w Dynamisches 610, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat 527w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat 530w Dynamisches 590, 0112000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat 540w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat 545w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat 610w Dynamisches 620, 016000M30x1, 5 AG malemagnetically coupled, st-60–200
Unistat 615w Dynamisches 620, 0112000M30x1, 5 AG malePressure pump, variable -60–200
Unistat 620w Dynamisches 680, 0112000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat 630w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat 635w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat 640w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat 645w Dynamisches —0, 0136000flange DN32 PN10/40 EN10magnetically coupled, st-60–200
Unistat 650w Dynamisches 730, 0148000flange DN32 PN10/40 EN10magnetically coupled, st-60–200
Unistat 680w Dynamisches —0, 0196000DN50 PN16 (DIN EN 1092-1magnetically coupled, st-60–200
Unistat GL 530w Dynamisches 610, 016000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL 535w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL 540w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL 550w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL 560w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL 570w Dynamisches —0, 0148000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P530w Dynamisches 610, 016000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P535w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P540w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P550w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P560w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P570w Dynamisches —0, 0148000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat P510 Dynamisches 600, 016000M30x1, 5 AG malemagnetically coupled, st-50–250
Unistat P510w Dynamisches 600, 016000M30x1, 5 AG malemagnetically coupled, st-50–250
Unistat P515w Dynamisches —0, 016000M30x1, 5 AG malemagnetically coupled, st-50–250
Unistat P520 Dynamisches —0, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat P520w Dynamisches 610, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat P525 Dynamisches 560, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat P525w Dynamisches 610, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat P527w Dynamisches 570, 0112000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat P530w Dynamisches 620.0112000M38x1,5 AG malemagnetically coupled, st-55–250
Unistat P540w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat P545w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat P610 Dynamisches —0, 016000M30x1, 5 AG malemagnetically coupled, st-60–200
Unistat P610w Dynamisches 620, 016000M30x1, 5 AG malemagnetically coupled, st-60–200
Unistat P615 Dynamisches —0, 0112000M30x1, 5 AG malemagnetically coupled, st-60–200
Unistat P615w Dynamisches 620, 0112000M30x1, 5 AG malemagnetically coupled, st-60–200
Unistat P620w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat P625w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat P630w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat P635w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat P645w Dynamisches —0, 0136000flange DN32 PN10/40 EN10magnetically coupled, st-60–200
Unistat P650w Dynamisches —0, 0148000flange DN32 PN10/40 EN10magnetically coupled, st-60–200

Full specifications

Core Performance & Functional Specifications
Control output POKO ONE
Heating capacity 12 kW
Pump connection M38x1, 5 AG male
Pump speed adjustable Yes
Pump type magnetically coupled, stainless steel
External sensor connection Pt100
Temperature range -60...200 °C
Electrical, Power & Drive Specifications
Power supply 460V 3~ 60Hz
Interfaces, Connections & Control
Controller Pilot ONE
Display resolution 0, 01 K
Digital interface Ethernet, USB (Host u. Device), RS232
Materials, Media & Process Compatibility
Maximum viscosity 100 mm²/s
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C
Cooling water connection G3/4 male
Cooling water differential pressure 1 bar (min)
Cooling Water Pressure 6 bar (max)
Protection rating IP20
Standards, Safety & General Data
Safety class III / FL

Description

Construction and series positioning

Behavior under load and media

Installation, control and operation

Integration & Operating Notes

Cooling & Media
Cooling water pressure and differential must be verified on site

The water-cooled condenser requires a cooling water supply with minimum 1 bar differential pressure and maximum 6 bar pressure. Insufficient differential pressure causes inadequate cooling; overpressure can damage the circuit. Confirm both values at the installation point before commissioning.

Unistat 625w Technical Data, page 2
Cooling & Media
Cooling water intake temperature must stay between 5 and 20 °C

Achievable cooling power depends on the cooling water intake temperature, and condensation risk rises at low intake temperatures. Insulate pipes where condensation conditions occur. Operating outside 5–20 °C intake affects performance and reliability.

Unistat 625w Technical Data, page 2
Electrical
Supply must be 460 V 3~ 60 Hz with UL 489 branch protection

The unit requires a 460 V three-phase 60 Hz supply and external branch circuit protection according to UL 489. Voltage tolerance is ±5% only with simultaneous frequency tolerance of ±2%; combinations such as -5% voltage with +2% frequency are not allowed. Confirm site supply before ordering.

Unistat 625w Technical Data, page 2
Electrical
Three-phase unit delivered with cable but without plug

Because current consumption is below 63 A, the unit ships with a cable but no plug. The customer must provide a suitable plug and have the connection made by an electrician, matching the rating plate voltage and frequency.

Unistat 625w Technical Data, page 2; Unistat Operation Manual, page 37
Process Limits
Heat transfer fluid viscosity must not exceed 100 mm²/s

The magnetically coupled stainless-steel pump is limited to a maximum kinematic viscosity of 100 mm²/s. Selecting a fluid that is too viscous at the lowest operating temperature can overload the pump and reduce circulation, so fluid choice must be checked against the -60 °C end of the range.

Unistat 625w Technical Data, page 1
Process Limits
Flammable fluids require fire point ≥65 °C and supervision

With safety class III / FL, any flammable heat transfer fluid used must have a fire point of at least 65 °C. If ethanol is used, only supervised operation is permitted. This constrains fluid selection and staffing for the application.

Unistat Operation Manual, Section 1.7 / page 19
Mounting
Do not install or start the unit inside an ATEX zone

Without an Ex px cabinet the unit is not protected against explosion and must not be installed or started within an ATEX zone. Site selection must exclude hazardous areas; Ex px operation requires the separate ATEX annex and only the model/serial on the Ex px rating plate is suitable.

Unistat Operation Manual, Section 1.3.3 / page 15-16
Control & I/O
Process Safety mode requires compressor set to Permanently ON

In Process Safety mode the controller releases maximum cooling capacity at the overtemperature trigger instead of switching off all poles. This mode requires the compressor to be set to Permanently ON; configure this in the Pilot ONE before relying on the function for exothermic processes.

Unistat Operation Manual, Section 1.7.2 / page 20; page 19
Control & I/O
Choose power-failure restart behavior for unattended operation

The Pilot ONE can be set to 'Off/Standby' (default, manual restart) or 'ON/Temperature control active' (automatic restart after power interruption, with a brief INFO allowing cancellation). Power Failure Auto resumes temperature control if it was active. Select according to whether unattended restart is acceptable for the process.

Unistat Operation Manual, Section 1.8.1 / page 21; page 20
Maintenance
Shut off cooling water even for overnight downtime

The cooling water supply should be shut off even for short downtimes such as overnight to prevent water damage and unnecessary load on the cooling water circuit. Periodically check hoses and connections for leaks and quality and replace as needed.

Unistat Operation Manual, page 29
Maintenance
Refrigerant circuit work only by approved contractors

Work on the coolant circuit must be carried out by approved refrigeration/air-conditioning system contractors. The refrigerant R-452A has a GWP of 2141, which may trigger regulatory, reporting or leakage-control obligations at the site.

Unistat Operation Manual, Section 1.4.2 / page 19; Unistat 625w Technical Data, page 1

Selection & Integration Q&A

When should I choose the Unistat 625w Dynamisches instead of a sibling like the 525 Dynamisches or 520w Dynamisches?

Choose the 625w when you need a water-cooled unit with 12 kW heating and -60…200 °C range and have a suitable cooling water supply (1–4 bar differential, 5–20 °C intake). If no cooling water is available, an air-cooled sibling such as the 525 Dynamisches avoids the water connection; the 520w is also water-cooled but a different size in the series.

What cooling water and electrical supply must be prepared for this unit before installation?

Provide cooling water at 5–20 °C intake with minimum 1 bar differential and maximum 6 bar pressure, connected via G3/4 male. Electrical supply must be 460 V 3~ 60 Hz with external UL 489 branch protection; the unit ships with cable but no plug, so a suitable plug must be provided and connection made by an electrician.

What are the ambient and installation limits for the 625w Dynamisches?

Operate within 5…40 °C ambient. Do not install in an ATEX zone. Transport and store upright only, allow 2 hours acclimation after temperature changes before power-on, and activate leveling feet or parking brakes before commissioning. Insulate cooling water pipes where condensation occurs.

What maintenance and accessories are required beyond the base delivery?

The unit ships without a plug; provide one. A drip tray for condensation water/heat transfer fluid must be installed below the unit. Shut off cooling water even overnight, periodically check hoses and connections, and have refrigerant-circuit work done by approved contractors. Heat transfer fluid is not included and must meet the 100 mm²/s viscosity limit.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Unistat 625w Technical Data
Datasheet ·18,7 КБ ·2 pp.
View PDF
PDF
Unistat® Operation Manual — Unistat® 5, Unistat® Pilot ONE®
Manual ·3,6 МБ ·100 pp.
View PDF
PDF
Unistat Operation Manual
Manual ·3,7 МБ ·102 pp.
View PDF