Peter Huber Kältemaschinenbau Unistat 650w Dynamisches
Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau Unistat 650w Dynamisches

Peter Huber Kältemaschinenbau Unistat 650w Dynamisches — Temperature control units with Noise level 73 dB.

The Unistat 650w Dynamisches is a water-cooled, free-standing temperature control unit with a -60 to 200 °C range, 48 kW heating and 65 kW cooling at 200/100 °C with Thermooil. Its 346 l/min magnetically coupled stainless pump and DN32 flange distinguish it from smaller 5xx siblings. It serves large exothermic reactor circuits requiring high heat-extraction capacity.

Noise level
73 dB

Peter Huber Kältemaschinenbau Unistat Series — Model Comparison & Selection

Model Noise level, dBDisplay resolutionHeating capacity, WPump connectionPump typeTemperature range, °C
Unistat 650w Dynamisches Current 730, 0148000flange DN32 PN10/40 EN10magnetically coupled, st-60–200
Unistat 510w Dynamisches 600, 016000M30x1, 5 AG malemagnetically coupled, st-50–250
Unistat 515w Dynamisches —0, 016000M30x1, 5 AG malemagnetically coupled, st-50–250
Unistat 520w Dynamisches 610, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat 525 Dynamisches 560, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat 525w Dynamisches 610, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat 527w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat 530w Dynamisches 590, 0112000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat 540w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat 545w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat 610w Dynamisches 620, 016000M30x1, 5 AG malemagnetically coupled, st-60–200
Unistat 615w Dynamisches 620, 0112000M30x1, 5 AG malePressure pump, variable -60–200
Unistat 620w Dynamisches 680, 0112000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat 625w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat 630w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat 635w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat 640w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat 645w Dynamisches —0, 0136000flange DN32 PN10/40 EN10magnetically coupled, st-60–200
Unistat 680w Dynamisches —0, 0196000DN50 PN16 (DIN EN 1092-1magnetically coupled, st-60–200
Unistat GL 530w Dynamisches 610, 016000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL 535w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL 540w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL 550w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL 560w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL 570w Dynamisches —0, 0148000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P530w Dynamisches 610, 016000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P535w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P540w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P550w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P560w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P570w Dynamisches —0, 0148000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat P510 Dynamisches 600, 016000M30x1, 5 AG malemagnetically coupled, st-50–250
Unistat P510w Dynamisches 600, 016000M30x1, 5 AG malemagnetically coupled, st-50–250
Unistat P515w Dynamisches —0, 016000M30x1, 5 AG malemagnetically coupled, st-50–250
Unistat P520 Dynamisches —0, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat P520w Dynamisches 610, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat P525 Dynamisches 560, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat P525w Dynamisches 610, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat P527w Dynamisches 570, 0112000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat P530w Dynamisches 620.0112000M38x1,5 AG malemagnetically coupled, st-55–250
Unistat P540w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat P545w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat P610 Dynamisches —0, 016000M30x1, 5 AG malemagnetically coupled, st-60–200
Unistat P610w Dynamisches 620, 016000M30x1, 5 AG malemagnetically coupled, st-60–200
Unistat P615 Dynamisches —0, 0112000M30x1, 5 AG malemagnetically coupled, st-60–200
Unistat P615w Dynamisches 620, 0112000M30x1, 5 AG malemagnetically coupled, st-60–200
Unistat P620w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat P625w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat P630w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat P635w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat P645w Dynamisches —0, 0136000flange DN32 PN10/40 EN10magnetically coupled, st-60–200
Unistat P650w Dynamisches —0, 0148000flange DN32 PN10/40 EN10magnetically coupled, st-60–200

Full specifications

Core Performance & Functional Specifications
Noise level 73 dB(A) (sound pressure level)
Control output POKO ONE (potential-free contact)
Expansion volume 95 l
Filling volume 46 l (min)
Heating capacity 48 kW
Pump connection flange DN32 PN10/40 EN1092-1
Pump speed adjustable Yes
Pump type magnetically coupled, stainless steel
External sensor connection Pt100
Temperature range -60...200 °C
Dimensions, Weight & Mechanical Design
Weight 1617 kg (net)
Electrical, Power & Drive Specifications
Current consumption 105 A (max)
Power supply 400V 3~ 50Hz
Interfaces, Connections & Control
Controller Pilot ONE
Display resolution 0, 01 K
Digital interface Ethernet, USB (Host u. Device), RS232
Materials, Media & Process Compatibility
Maximum viscosity 50 mm²/s (max)
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C (permissible)
Cooling water connection G1 1/4 male
Cooling water consumption 3110 l/h (at 15°C, flow 0°C)
Cooling water differential pressure 1 bar (min)
Cooling Water Pressure 6 bar (max)
Protection rating IP20
Standards, Safety & General Data
Safety class III / FL

Description

Construction and series positioning

Behavior across the working range

Control, connection and operation

Integration & Operating Notes

Electrical
Power cable and plug are not supplied — plan site termination

With a maximum current of 105 A the unit exceeds the 63 A threshold and is delivered without cable and without plug. The customer must procure and terminate a 400 V 3~ 50 Hz feed with 3×125 A fusing, executed by an electrician, and verify supply tolerance (±5% voltage with ±2% frequency; -5% voltage with +2% frequency is not allowed).

Unistat 650w Technical Data, page 2; Operation Manual, Section on power connection
Electrical
High leakage current demands suitable RCD and earthing design

Leakage current exceeds 3.5 mA, so protective earthing and residual current device selection must be rated for high-leakage equipment rather than standard 30 mA assumptions. Electrical protection design should be reviewed before commissioning.

Unistat 650w Technical Data, page 2
Cooling & Media
Cooling water must meet pressure, temperature and material limits

Connection is G1 1/4 male with minimum differential pressure 1 bar and maximum pressure 6 bar; design intake is 5–20 °C and consumption reaches 3110 l/h at 15 °C. Below the condensation point the cooling water pipes must be insulated, and only water compatible with copper, 1.4401 stainless, MS, PA, PPE, PTFE and EPDM may be used.

Unistat 650w Technical Data, page 2
Process Limits
External circuit pressure drop must fit the pump curve

The pump delivers 346 l/min maximum at 4 bar maximum delivery pressure, falling to 173 l/min at 3.5 bar. Mating pipework and heat exchangers must be sized so the loop resistance at the required flow stays on this curve; the DN32 PN10/40 EN1092-1 flange defines the mechanical interface.

Unistat 650w Technical Data, pages 1–2
Mounting
Install indoors, outside ATEX zones, on a verified floor

IP20 protection and 5–40 °C ambient restrict the unit to dry indoor areas; installation or start-up inside an ATEX zone is prohibited. At 1617 kg and 1850×1348×2167 mm, floor loading, transport route and rigging must be verified, and the unit must be transported and stored upright only — horizontal transport damages the compressor.

Unistat 650w Technical Data, page 2; Operation Manual, Section 1.3.3 and Commissioning
Mounting
Level the unit and provide a drip tray before start-up

Leveling feet must be unscrewed/activated and caster parking brakes engaged before commissioning; casters are not for transport and carry only 25% of total mass. The responsible body must install a condensation water / heat transfer fluid drip tray below the unit, and local legislation may prescribe it.

Operation Manual, Commissioning and Section 1.4
Control & I/O
Set power-failure restart behavior deliberately

Pilot ONE can be configured to 'Off/Standby' (default, manual restart) or 'ON/Temperature control active' (automatic restart after power return, with a brief INFO allowing cancellation). Choose according to whether unattended restart is acceptable for the process; Process Safety mode additionally requires the compressor set to Permanently ON.

Operation Manual, Section 1.8.1 and Setup Mode
Maintenance
Shut off cooling water during even short downtimes

The cooling water supply should be shut off even for short downtimes such as overnight to prevent water damage and unnecessary load on the circuit. Hoses and connections must be periodically checked for leaks and quality and replaced as required; refrigerant-circuit work is reserved for approved refrigeration/air-conditioning contractors.

Operation Manual, Commissioning and Section 1.4.2

Selection & Integration Q&A

When should I choose the Unistat 650w over the smaller 510w/515w/520w/525 siblings?

Pick the 650w when the process needs 48 kW heating and up to 65 kW cooling with a 346 l/min, 4 bar pump on a DN32 flange. The smaller siblings have lower noise (56–61 dB(A) vs 73 dB(A)) and suit lower heat loads; the 650w is for large reactor circuits where capacity, not acoustics, dominates.

What must the site provide for power and cooling water to integrate this unit?

A 400 V 3~ 50 Hz feed with 3×125 A fusing and a site-terminated cable (no cable/plug supplied above 63 A), plus cooling water at G1 1/4 male, 1 bar min differential and 6 bar max pressure, 5–20 °C intake, up to 3110 l/h. External pipework must mate the DN32 PN10/40 EN1092-1 flange.

What installation environment and duty-cycle limits apply?

Indoor dry location only (IP20), 5–40 °C ambient, never inside an ATEX zone. Transport and store upright only; allow ~2 h acclimation after cold/warm moves. Leveling feet and drip tray are mandatory, and cooling water should be shut off even overnight.

What maintenance and accessories are not included in base delivery?

The power cable and plug are not supplied (current >63 A). A drip tray must be provided by the responsible body. Periodic checks of hoses and connections, cleaning of liquefier fins and strainer, and heat transfer fluid inspection/replacement are user maintenance; refrigerant work requires approved contractors.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Unistat 650w Technical Data
Datasheet ·18,9 КБ ·2 pp.
View PDF
PDF
Unistat® Operation Manual — Unistat® 5, Unistat® Pilot ONE®
Manual ·3,6 МБ ·100 pp.
View PDF
PDF
Unistat Operation Manual
Manual ·3,7 МБ ·102 pp.
View PDF