Peter Huber Kältemaschinenbau Unistat 650w Dynamisches
Peter Huber Kältemaschinenbau Unistat 650w Dynamisches — Temperature control units with Noise level 73 dB.
The Unistat 650w Dynamisches is a water-cooled, free-standing temperature control unit with a -60 to 200 °C range, 48 kW heating and 65 kW cooling at 200/100 °C with Thermooil. Its 346 l/min magnetically coupled stainless pump and DN32 flange distinguish it from smaller 5xx siblings. It serves large exothermic reactor circuits requiring high heat-extraction capacity.
Peter Huber Kältemaschinenbau Unistat Series — Model Comparison & Selection
| Model | Noise level, dB | Display resolution | Heating capacity, W | Pump connection | Pump type | Temperature range, °C |
|---|---|---|---|---|---|---|
| Unistat 650w Dynamisches Current | 73 | 0, 01 | 48000 | flange DN32 PN10/40 EN10 | magnetically coupled, st | -60–200 |
| Unistat 510w Dynamisches | 60 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat 515w Dynamisches | — | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat 520w Dynamisches | 61 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 525 Dynamisches | 56 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 525w Dynamisches | 61 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 527w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 530w Dynamisches | 59 | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 540w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 545w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 610w Dynamisches | 62 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 615w Dynamisches | 62 | 0, 01 | 12000 | M30x1, 5 AG male | Pressure pump, variable | -60–200 |
| Unistat 620w Dynamisches | 68 | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 625w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 630w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 635w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 640w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 645w Dynamisches | — | 0, 01 | 36000 | flange DN32 PN10/40 EN10 | magnetically coupled, st | -60–200 |
| Unistat 680w Dynamisches | — | 0, 01 | 96000 | DN50 PN16 (DIN EN 1092-1 | magnetically coupled, st | -60–200 |
| Unistat GL 530w Dynamisches | 61 | 0, 01 | 6000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 535w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 540w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 550w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 560w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 570w Dynamisches | — | 0, 01 | 48000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P530w Dynamisches | 61 | 0, 01 | 6000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P535w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P540w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P550w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P560w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P570w Dynamisches | — | 0, 01 | 48000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat P510 Dynamisches | 60 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat P510w Dynamisches | 60 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat P515w Dynamisches | — | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat P520 Dynamisches | — | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P520w Dynamisches | 61 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P525 Dynamisches | 56 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P525w Dynamisches | 61 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P527w Dynamisches | 57 | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P530w Dynamisches | 62 | 0.01 | 12000 | M38x1,5 AG male | magnetically coupled, st | -55–250 |
| Unistat P540w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P545w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P610 Dynamisches | — | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P610w Dynamisches | 62 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P615 Dynamisches | — | 0, 01 | 12000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P615w Dynamisches | 62 | 0, 01 | 12000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P620w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P625w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P630w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P635w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P645w Dynamisches | — | 0, 01 | 36000 | flange DN32 PN10/40 EN10 | magnetically coupled, st | -60–200 |
| Unistat P650w Dynamisches | — | 0, 01 | 48000 | flange DN32 PN10/40 EN10 | magnetically coupled, st | -60–200 |
Full specifications
| Noise level | 73 dB(A) (sound pressure level) |
| Control output | POKO ONE (potential-free contact) |
| Expansion volume | 95 l |
| Filling volume | 46 l (min) |
| Heating capacity | 48 kW |
| Pump connection | flange DN32 PN10/40 EN1092-1 |
| Pump speed adjustable | Yes |
| Pump type | magnetically coupled, stainless steel |
| External sensor connection | Pt100 |
| Temperature range | -60...200 °C |
| Weight | 1617 kg (net) |
| Current consumption | 105 A (max) |
| Power supply | 400V 3~ 50Hz |
| Controller | Pilot ONE |
| Display resolution | 0, 01 K |
| Digital interface | Ethernet, USB (Host u. Device), RS232 |
| Maximum viscosity | 50 mm²/s (max) |
| Ambient temperature limit | 5...40 °C (permissible) |
| Cooling water connection | G1 1/4 male |
| Cooling water consumption | 3110 l/h (at 15°C, flow 0°C) |
| Cooling water differential pressure | 1 bar (min) |
| Cooling Water Pressure | 6 bar (max) |
| Protection rating | IP20 |
| Safety class | III / FL |
Description
Construction and series positioning
- Free-standing water-cooled (w) Unistat 6xx platform: 1850×1348×2167 mm, 1617 kg net, IP20, indoor dry installation only.
- Two refrigerant stages, each with 2.8 kg R-1270 (A3, H220 flammable natural refrigerant); cooling water circuit materials include copper, 1.4401 stainless, MS, PA, PPE, PTFE and EPDM.
- Positioned above the 510w/515w/520w/525 siblings in capacity: 48 kW heating, 65 kW cooling at 200 °C and 100 °C with Thermooil, versus the smaller frames' lower noise envelopes (56–61 dB(A) vs 73 dB(A) here).
- Pump: magnetically coupled stainless steel, speed-adjustable, DN32 PN10/40 EN1092-1 flange, 346 l/min max delivery, 4 bar max delivery pressure.
Behavior across the working range
- Cooling capacity is medium-dependent: 65 kW at 200 °C and 100 °C (Thermooil), 65 kW at 0 °C and 56 kW at -20 °C, 28 kW at -40 °C, 9.5 kW at -60 °C (ethanol). Process heat load must be checked at the actual setpoint, not at the nominal top of the range.
- Pump curve falls to 173 l/min at 3.5 bar; external circuit pressure drop must be matched to this curve.
- Temperature range -60…200 °C, display resolution 0.01 K, max viscosity 50 mm²/s; filling volume min 46 l, expansion volume 95 l.
- Safety class III / FL: with flammable heat transfer fluid the fire point must be ≥65 °C, and ethanol use is permitted only under supervision.
Control, connection and operation
- Pilot ONE controller with POKO ONE potential-free contact, Ethernet, USB host/device and RS232; external Pt100 sensor input; adjustable pump speed.
- 400 V 3~ 50 Hz, max 105 A, 3×125 A fusing; because current exceeds 63 A the unit ships without cable and without plug — site termination by an electrician.
- Cooling water G1 1/4 male, min differential pressure 1 bar, max pressure 6 bar, consumption 3110 l/h at 15 °C; intake design 5–20 °C, insulate pipes below the condensation point.
- Leakage current >3.5 mA; supply tolerance ±5% voltage with ±2% frequency, and the combination -5% voltage with +2% frequency is not permitted.
Integration & Operating Notes
With a maximum current of 105 A the unit exceeds the 63 A threshold and is delivered without cable and without plug. The customer must procure and terminate a 400 V 3~ 50 Hz feed with 3×125 A fusing, executed by an electrician, and verify supply tolerance (±5% voltage with ±2% frequency; -5% voltage with +2% frequency is not allowed).
Leakage current exceeds 3.5 mA, so protective earthing and residual current device selection must be rated for high-leakage equipment rather than standard 30 mA assumptions. Electrical protection design should be reviewed before commissioning.
Connection is G1 1/4 male with minimum differential pressure 1 bar and maximum pressure 6 bar; design intake is 5–20 °C and consumption reaches 3110 l/h at 15 °C. Below the condensation point the cooling water pipes must be insulated, and only water compatible with copper, 1.4401 stainless, MS, PA, PPE, PTFE and EPDM may be used.
The pump delivers 346 l/min maximum at 4 bar maximum delivery pressure, falling to 173 l/min at 3.5 bar. Mating pipework and heat exchangers must be sized so the loop resistance at the required flow stays on this curve; the DN32 PN10/40 EN1092-1 flange defines the mechanical interface.
IP20 protection and 5–40 °C ambient restrict the unit to dry indoor areas; installation or start-up inside an ATEX zone is prohibited. At 1617 kg and 1850×1348×2167 mm, floor loading, transport route and rigging must be verified, and the unit must be transported and stored upright only — horizontal transport damages the compressor.
Leveling feet must be unscrewed/activated and caster parking brakes engaged before commissioning; casters are not for transport and carry only 25% of total mass. The responsible body must install a condensation water / heat transfer fluid drip tray below the unit, and local legislation may prescribe it.
Pilot ONE can be configured to 'Off/Standby' (default, manual restart) or 'ON/Temperature control active' (automatic restart after power return, with a brief INFO allowing cancellation). Choose according to whether unattended restart is acceptable for the process; Process Safety mode additionally requires the compressor set to Permanently ON.
The cooling water supply should be shut off even for short downtimes such as overnight to prevent water damage and unnecessary load on the circuit. Hoses and connections must be periodically checked for leaks and quality and replaced as required; refrigerant-circuit work is reserved for approved refrigeration/air-conditioning contractors.
Selection & Integration Q&A
Pick the 650w when the process needs 48 kW heating and up to 65 kW cooling with a 346 l/min, 4 bar pump on a DN32 flange. The smaller siblings have lower noise (56–61 dB(A) vs 73 dB(A)) and suit lower heat loads; the 650w is for large reactor circuits where capacity, not acoustics, dominates.
A 400 V 3~ 50 Hz feed with 3×125 A fusing and a site-terminated cable (no cable/plug supplied above 63 A), plus cooling water at G1 1/4 male, 1 bar min differential and 6 bar max pressure, 5–20 °C intake, up to 3110 l/h. External pipework must mate the DN32 PN10/40 EN1092-1 flange.
Indoor dry location only (IP20), 5–40 °C ambient, never inside an ATEX zone. Transport and store upright only; allow ~2 h acclimation after cold/warm moves. Leveling feet and drip tray are mandatory, and cooling water should be shut off even overnight.
The power cable and plug are not supplied (current >63 A). A drip tray must be provided by the responsible body. Periodic checks of hoses and connections, cleaning of liquefier fins and strainer, and heat transfer fluid inspection/replacement are user maintenance; refrigerant work requires approved contractors.