Peter Huber Kältemaschinenbau Unistat GL P530w Dynamisches
Peter Huber Kältemaschinenbau Unistat GL P530w Dynamisches — Temperature control units with Noise level 61 dB.
The Unistat GL P530w Dynamisches is a water-cooled, CO2-refrigerant (GL) free-standing temperature control unit with a magnetically coupled stainless-steel pump and Pilot ONE controller, covering -50 to 200 °C with 6 kW heating. Its 'P' designation targets applications with high pressure drop, delivering 87 l/min at 4.0 bar. It serves precise temperature control of externally closed circuits in pilot-plant and process automation.
Peter Huber Kältemaschinenbau Unistat Series — Model Comparison & Selection
| Model | Noise level, dB | Display resolution | Heating capacity, W | Pump connection | Pump type | Temperature range, °C |
|---|---|---|---|---|---|---|
| Unistat GL P530w Dynamisches Current | 61 | 0, 01 | 6000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat 510w Dynamisches | 60 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat 515w Dynamisches | — | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat 520w Dynamisches | 61 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 525 Dynamisches | 56 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 525w Dynamisches | 61 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 527w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 530w Dynamisches | 59 | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 540w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 545w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 610w Dynamisches | 62 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 615w Dynamisches | 62 | 0, 01 | 12000 | M30x1, 5 AG male | Pressure pump, variable | -60–200 |
| Unistat 620w Dynamisches | 68 | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 625w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 630w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 635w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 640w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 645w Dynamisches | — | 0, 01 | 36000 | flange DN32 PN10/40 EN10 | magnetically coupled, st | -60–200 |
| Unistat 650w Dynamisches | 73 | 0, 01 | 48000 | flange DN32 PN10/40 EN10 | magnetically coupled, st | -60–200 |
| Unistat 680w Dynamisches | — | 0, 01 | 96000 | DN50 PN16 (DIN EN 1092-1 | magnetically coupled, st | -60–200 |
| Unistat GL 530w Dynamisches | 61 | 0, 01 | 6000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 535w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 540w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 550w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 560w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 570w Dynamisches | — | 0, 01 | 48000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P535w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P540w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P550w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P560w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P570w Dynamisches | — | 0, 01 | 48000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat P510 Dynamisches | 60 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat P510w Dynamisches | 60 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat P515w Dynamisches | — | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat P520 Dynamisches | — | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P520w Dynamisches | 61 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P525 Dynamisches | 56 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P525w Dynamisches | 61 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P527w Dynamisches | 57 | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P530w Dynamisches | 62 | 0.01 | 12000 | M38x1,5 AG male | magnetically coupled, st | -55–250 |
| Unistat P540w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P545w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P610 Dynamisches | — | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P610w Dynamisches | 62 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P615 Dynamisches | — | 0, 01 | 12000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P615w Dynamisches | 62 | 0, 01 | 12000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P620w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P625w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P630w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P635w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P645w Dynamisches | — | 0, 01 | 36000 | flange DN32 PN10/40 EN10 | magnetically coupled, st | -60–200 |
| Unistat P650w Dynamisches | — | 0, 01 | 48000 | flange DN32 PN10/40 EN10 | magnetically coupled, st | -60–200 |
Full specifications
| Noise level | 61 dB(A) |
| Control output | POKO ONE |
| Heating capacity | 6 kW |
| Pump connection | M38x1, 5 AG male |
| Pump speed adjustable | Yes |
| Pump type | magnetically coupled, stainless steel |
| External sensor connection | Pt100 |
| Temperature range | -50...200 °C |
| Power supply | 400V 3~ 50Hz |
| Controller | Pilot ONE |
| Display resolution | 0, 01 K |
| Digital interface | Ethernet, USB (Host u. Device), RS232 |
| Maximum viscosity | 100 mm²/s |
| Ambient temperature limit | 5...40 °C |
| Cooling water connection | G3/4 male |
| Cooling water consumption | 620 l/h (at 15°C, flow 0°C) |
| Cooling water differential pressure | 1 bar (min.) |
| Cooling Water Pressure | 6 bar (max.) |
| Protection rating | IP20 |
| Safety class | III / FL |
Description
Construction and series positioning
- Free-standing Unistat 5xx-class unit; model-name suffixes decode as GL = CO2 refrigerant, w = water-cooled, P = for applications with high pressure drop. This is the water-cooled CO2 variant of the 5xx frame, distinct from air-cooled siblings (Unistat 510w, 515w, 520w, 525 Dynamisches).
- Pump is magnetically coupled, stainless steel, speed-adjustable; pump connection M38x1.5 male with bore shape Y (60°) per DIN 3863, mating ball socket DIN 3863 and sleeve nut DIN 3870.
- Cooling water circuit materials: copper, stainless steel 1.4401, MS, PA, PPE, PTFE, EPDM. Refrigerant R-744 (A1, H280), GWP 1.
- Safety class III/FL with adjustable overtemperature protection per DIN 12876; protection rating IP20; EMC Class A, Group 1 per EN55011.
Behavior under load
- Temperature range -50…200 °C; heating capacity 6 kW. Cooling capacity is strongly medium- and temperature-dependent: 12 kW with Thermooil at 20–200 °C, but only 1.5 kW with ethanol at -50 °C.
- Pump delivery falls with system pressure: 201 l/min max, 179 l/min at 1.0 bar, 87 l/min at 4.0 bar — the 'P' modification is intended where the external circuit imposes high pressure drop.
- Cooling water: 620 l/h consumption at 15 °C water / 0 °C flow; 1 bar min differential pressure, 6 bar max. Rising cooling-water temperature reduces cooling power and may require higher flow.
Control, installation and operation
- Pilot ONE controller with POKO ONE control output; display resolution 0.01 K; interfaces Ethernet, USB host and device, RS232; external Pt100 sensor connection.
- 400 V 3~ 50 Hz supply; voltage tolerance ±5% only with ±2% frequency tolerance, and the combination -5% voltage with +2% frequency is not allowed. Three-phase connections below 63 A are supplied with cable but no plug.
- Cooling water intake 5–20 °C; insulate cooling-water pipes when water temperature can fall below dew point. Unit dimensions 730×804×1738 mm; ambient 5–40 °C; noise 61 dB(A).
- Overtemperature protection settable (OT limit heating, OT expansion vessel, Process Safety); 'Process safety' mode releases maximum cooling at the trigger value instead of all-pole switch-off and requires the compressor set to Permanently ON.
Integration & Operating Notes
Intake temperature must be 5–20 °C with 1–4 bar differential pressure and maximum 6 bar pressure. As cooling-water temperature rises, expect a drop in cooling power and possibly a higher required flow rate. Insulate cooling-water pipes whenever water temperature can fall below the dew point to prevent condensation on the unit.
Cooling capacity is 12 kW with Thermooil at 20–200 °C but only 1.5 kW with ethanol at -50 °C. Size the process load against the actual heat-transfer fluid and operating temperature, not against the headline capacity; low-temperature ethanol duty leaves little margin for exothermic or high-dissipation loads.
For externally closed applications the expansion vessel must remain unlocked; locking it will damage the application due to overpressure. Conversely, for externally open (bath) applications the expansion vessel must be locked to prevent fluid loss. Confirm the application type before commissioning and set the vessel state accordingly.
When moving the unit between cold and warm environments (or vice versa), let it acclimate for about 2 hours before switching on. Powering up immediately can cause condensation-induced electrical faults. Also transport and store upright only, and move only an emptied unit.
In 'Process safety' mode the controller releases maximum cooling capacity at the overtemperature trigger instead of switching off all poles, which protects exothermic processes. This mode requires the compressor to be set to Permanently ON; configure this before relying on the function. The alternative power-interruption behavior (Off/Standby vs ON) determines whether the unit restarts unattended.
Close the cooling-water supply even for short downtimes such as overnight to avoid water damage and unnecessary load on the circuit. Periodically check hoses and hose connections for leaks and quality and replace as required; clean the liquefier fins and the hat-type strainer/dirt trap as part of scheduled maintenance.
The unit must not be installed or started within an ATEX zone; explosion protection requires a separate Ex px cabinet. Use with medical devices (e.g. in vitro diagnostic procedures) or for direct foodstuff temperature control is not permissible. Refrigerant-circuit work must be performed by approved refrigeration/air-conditioning contractors.
Selection & Integration Q&A
Pick this water-cooled CO2 (GL) 'P' variant when the external circuit has high pressure drop (87 l/min at 4.0 bar) and a facility cooling-water supply of 5–20 °C is available. Air-cooled siblings suit sites without cooling water; non-P variants suit low-pressure-drop circuits.
Cooling water: G3/4 male, 5–20 °C, 1–4 bar differential, max 6 bar, 620 l/h at 15 °C. Process pump connection: M38x1.5 male, bore shape Y (60°) per DIN 3863; use ball socket DIN 3863 and sleeve nut DIN 3870. Insulate pipes if below dew point.
Ambient 5–40 °C, IP20, EMC Class A Group 1 (may restrict residential use), no ATEX zone. Transport upright and emptied; acclimate ~2 h before power-on. Choose Off/Standby or ON restart behavior per whether unattended restart is acceptable.
A condensation/fluid drip tray below the unit is the operator's responsibility and may be legally required. Cooling-water hoses, mating DIN 3863/3870 fittings, and the optional gas detection sensor/processing unit are not base scope; refrigerant work needs approved contractors.