Peter Huber Kältemaschinenbau Unistat GL P560w Dynamisches
Peter Huber Kältemaschinenbau Unistat GL P560w Dynamisches — Temperature control units.
The Unistat GL P560w Dynamisches is a water-cooled, CO2-refrigerant (GL) free-standing temperature control unit with a magnetically coupled stainless-steel pump and Pilot ONE controller, covering -50 to 200 °C with 24 kW heating. Its 'P' designation targets applications with high pressure drop, distinguishing it from standard 5xx siblings. It serves closed-loop process temperature control in industrial automation.
Peter Huber Kältemaschinenbau Unistat Series — Model Comparison & Selection
| Model | Noise level, dB | Display resolution | Heating capacity, W | Pump connection | Pump type | Temperature range, °C |
|---|---|---|---|---|---|---|
| Unistat GL P560w Dynamisches Current | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat 510w Dynamisches | 60 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat 515w Dynamisches | — | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat 520w Dynamisches | 61 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 525 Dynamisches | 56 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 525w Dynamisches | 61 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 527w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 530w Dynamisches | 59 | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 540w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 545w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 610w Dynamisches | 62 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 615w Dynamisches | 62 | 0, 01 | 12000 | M30x1, 5 AG male | Pressure pump, variable | -60–200 |
| Unistat 620w Dynamisches | 68 | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 625w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 630w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 635w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 640w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 645w Dynamisches | — | 0, 01 | 36000 | flange DN32 PN10/40 EN10 | magnetically coupled, st | -60–200 |
| Unistat 650w Dynamisches | 73 | 0, 01 | 48000 | flange DN32 PN10/40 EN10 | magnetically coupled, st | -60–200 |
| Unistat 680w Dynamisches | — | 0, 01 | 96000 | DN50 PN16 (DIN EN 1092-1 | magnetically coupled, st | -60–200 |
| Unistat GL 530w Dynamisches | 61 | 0, 01 | 6000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 535w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 540w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 550w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 560w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 570w Dynamisches | — | 0, 01 | 48000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P530w Dynamisches | 61 | 0, 01 | 6000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P535w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P540w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P550w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P570w Dynamisches | — | 0, 01 | 48000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat P510 Dynamisches | 60 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat P510w Dynamisches | 60 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat P515w Dynamisches | — | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat P520 Dynamisches | — | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P520w Dynamisches | 61 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P525 Dynamisches | 56 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P525w Dynamisches | 61 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P527w Dynamisches | 57 | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P530w Dynamisches | 62 | 0.01 | 12000 | M38x1,5 AG male | magnetically coupled, st | -55–250 |
| Unistat P540w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P545w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P610 Dynamisches | — | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P610w Dynamisches | 62 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P615 Dynamisches | — | 0, 01 | 12000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P615w Dynamisches | 62 | 0, 01 | 12000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P620w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P625w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P630w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P635w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P645w Dynamisches | — | 0, 01 | 36000 | flange DN32 PN10/40 EN10 | magnetically coupled, st | -60–200 |
| Unistat P650w Dynamisches | — | 0, 01 | 48000 | flange DN32 PN10/40 EN10 | magnetically coupled, st | -60–200 |
Full specifications
| Control output | POKO ONE |
| Heating capacity | 24 kW |
| Pump connection | M38x1, 5 AG male |
| Pump speed adjustable | Yes |
| Pump type | magnetically coupled, stainless steel |
| External sensor connection | Pt100 |
| Temperature range | -50...200 °C |
| Power supply | 400V 3~ 50Hz |
| Controller | Pilot ONE |
| Display resolution | 0, 01 K |
| Digital interface | Ethernet, USB (Host u. Device), RS232 |
| Maximum viscosity | 100 mm²/s |
| Ambient temperature limit | 5...40 °C |
| Cooling water connection | G3/4 male |
| Cooling water differential pressure | 1 bar (min) |
| Cooling Water Pressure | 6 bar (max) |
| Protection rating | IP20 |
| Safety class | III / FL |
Description
Construction and series positioning
- Free-standing Unistat 5xx-class unit; model-name suffix decoding: 'GL' = CO2 refrigerant, 'w' = water-cooled, 'P' = for applications with high pressure drop, 'Dynamisches' = dynamic temperature control.
- Sibling models in the series (Unistat 510w, 515w, 520w, 525 Dynamisches) differ in configuration; this P560w variant is the high-pressure-drop modification with water cooling and CO2 refrigerant.
- Refrigeration machine is water-cooled with natural refrigerant R-744 (GWP 1).
- Pump: magnetically coupled, stainless steel, speed-adjustable; pump connection M38x1.5 male.
- Controller: Pilot ONE with POKO ONE control output; display resolution 0.01 K; interfaces Ethernet, USB (Host and Device), RS232; external Pt100 sensor connection.
- Safety classification III / FL with adjustable overtemperature protection per DIN 12876.
Working range and media behavior
- Temperature range -50 to 200 °C; heating capacity 24 kW.
- Maximum permissible kinematic viscosity of the heat transfer fluid is 100 mm²/s.
- Minimum filling capacity 8.9 l; expansion tank 19.9 l.
- For FL-rated (flammable) heat transfer fluid, fire point must be ≥ 65 °C; ethanol only under supervised operation.
- Cooling water intake designed for 5–20 °C; lower intake temperatures require insulating the cooling water pipes. Cooling capacity drops and cooling water flow may need to increase as cooling water temperature rises.
- Cooling water circuit materials include copper, stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM — cooling water must be compatible.
Installation, connection and control
- Power supply 400 V 3~ 50 Hz; three-phase devices below 63 A are delivered with cable but without a plug.
- Voltage tolerance ±5% with simultaneous frequency tolerance ±2%; opposite-sign deviations not allowed.
- Cooling water connections G3/4 male; differential pressure min 1 bar (datasheet also states max 4 bar differential), max cooling water pressure 6 bar.
- Ambient temperature 5–40 °C; protection rating IP20; EN55011 Class A, Group 1.
- Expansion vessel must remain unlocked for externally closed applications and locked for externally open (bath) applications.
- Power-interruption behavior configurable via Pilot ONE: 'Off/Standby' (default) or 'ON/Temperature control active' with a brief INFO window to cancel automatic restart.
- Process Safety mode releases maximum cooling capacity at the OT trigger instead of switching off all poles; requires compressor set to Permanently ON.
Integration & Operating Notes
The 400 V 3~ 50 Hz connection is delivered with cable but without a plug for currents below 63 A, so a suitable plug must be sourced and the hard-wired connection made by an electrician. Supply must stay within ±5% voltage with simultaneous ±2% frequency tolerance; opposite-sign deviations are not permitted.
For externally closed applications the expansion vessel must remain unlocked — locking it causes overpressure damage to the application. For externally open (bath) applications the vessel must be locked to prevent fluid loss. Verify the isolating sleeve/valve state before commissioning.
Transport and store upright only — horizontal transport damages the compressor; move only an emptied unit. Allow about 2 hours acclimation when moving between cold and warm environments before switching on. Activate leveling feet and parking brakes before commissioning; casters are not for transport and carry only 25% of total mass symmetrically.
The unit must not be installed or started within an ATEX zone; explosion protection requires a separate Ex px cabinet. Use with medical devices (e.g. in vitro diagnostic procedures) or for direct foodstuff temperature control is not permissible. Ambient temperature must stay within 5–40 °C.
Selection & Integration Q&A
Pick the P560w when the application has high pressure drop (the 'P' designation) and you need water cooling with CO2 refrigerant (GL). Siblings like the 510w/520w are standard water-cooled variants without the high-pressure-drop modification; choose them when circuit pressure drop is not the constraint.
Provide cooling water at 1 bar minimum differential (max 4 bar differential per datasheet) and no more than 6 bar, through G3/4 male connections, with intake at 5–20 °C and materials compatible with copper, 1.4401, MS, PA, PPE, PTFE and EPDM. Process pipework must mate to the M38x1.5 male pump connection using DIN 3863 ball socket and DIN 3870 sleeve nut.
Install upright only, allow ~2 h acclimation after temperature changes before power-on, activate leveling feet and parking brakes, and keep ambient at 5–40 °C. Casters are not for transport (25% load only). The unit must not be installed in an ATEX zone, and medical-device or direct-food use is excluded.
A three-phase plug is not supplied (cable only below 63 A), and a condensation/heat transfer fluid drip tray must be installed by the responsible body. Periodic hose inspection/replacement, cooling water shutoff during downtimes, and refrigerant-circuit work by approved contractors must be scheduled; the optional gas detection sensor and processing unit are operating-company scope.