Peter Huber Kältemaschinenbau Unistat P510 Dynamisches — Temperature control units with Noise level 60 dB.

The Unistat P510 Dynamisches is a free-standing, air-cooled refrigerated heating circulator with a -50 to 250 °C working range, 6 kW heating and a magnetically coupled stainless-steel pump. Its 'P' designation targets applications with high pressure drop, distinguishing it from the w (water-cooled) and standard siblings in the Unistat 5xx series. It serves single-device temperature control of closed or open process loops in industrial environments.

Noise level
60 dB

Peter Huber Kältemaschinenbau Unistat Series — Model Comparison & Selection

Model Noise level, dBDisplay resolutionHeating capacity, WPump connectionPump typeTemperature range, °C
Unistat P510 Dynamisches Current 600, 016000M30x1, 5 AG malemagnetically coupled, st-50–250
Unistat 510w Dynamisches 600, 016000M30x1, 5 AG malemagnetically coupled, st-50–250
Unistat 515w Dynamisches —0, 016000M30x1, 5 AG malemagnetically coupled, st-50–250
Unistat 520w Dynamisches 610, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat 525 Dynamisches 560, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat 525w Dynamisches 610, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat 527w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat 530w Dynamisches 590, 0112000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat 540w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat 545w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat 610w Dynamisches 620, 016000M30x1, 5 AG malemagnetically coupled, st-60–200
Unistat 615w Dynamisches 620, 0112000M30x1, 5 AG malePressure pump, variable -60–200
Unistat 620w Dynamisches 680, 0112000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat 625w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat 630w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat 635w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat 640w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat 645w Dynamisches —0, 0136000flange DN32 PN10/40 EN10magnetically coupled, st-60–200
Unistat 650w Dynamisches 730, 0148000flange DN32 PN10/40 EN10magnetically coupled, st-60–200
Unistat 680w Dynamisches —0, 0196000DN50 PN16 (DIN EN 1092-1magnetically coupled, st-60–200
Unistat GL 530w Dynamisches 610, 016000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL 535w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL 540w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL 550w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL 560w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL 570w Dynamisches —0, 0148000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P530w Dynamisches 610, 016000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P535w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P540w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P550w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P560w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P570w Dynamisches —0, 0148000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat P510w Dynamisches 600, 016000M30x1, 5 AG malemagnetically coupled, st-50–250
Unistat P515w Dynamisches —0, 016000M30x1, 5 AG malemagnetically coupled, st-50–250
Unistat P520 Dynamisches —0, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat P520w Dynamisches 610, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat P525 Dynamisches 560, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat P525w Dynamisches 610, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat P527w Dynamisches 570, 0112000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat P530w Dynamisches 620.0112000M38x1,5 AG malemagnetically coupled, st-55–250
Unistat P540w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat P545w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat P610 Dynamisches —0, 016000M30x1, 5 AG malemagnetically coupled, st-60–200
Unistat P610w Dynamisches 620, 016000M30x1, 5 AG malemagnetically coupled, st-60–200
Unistat P615 Dynamisches —0, 0112000M30x1, 5 AG malemagnetically coupled, st-60–200
Unistat P615w Dynamisches 620, 0112000M30x1, 5 AG malemagnetically coupled, st-60–200
Unistat P620w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat P625w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat P630w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat P635w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat P645w Dynamisches —0, 0136000flange DN32 PN10/40 EN10magnetically coupled, st-60–200
Unistat P650w Dynamisches —0, 0148000flange DN32 PN10/40 EN10magnetically coupled, st-60–200

Full specifications

Core Performance & Functional Specifications
Noise level 60 dB(A) (sound pressure level)
Control output POKO ONE (potential-free contact)
Heating capacity 6 kW
Pump connection M30x1, 5 AG male
Pump speed adjustable Yes
Pump type magnetically coupled, stainless steel
External sensor connection Pt100
Temperature range -50...250 °C
Dimensions, Weight & Mechanical Design
Weight 232 kg (net)
Electrical, Power & Drive Specifications
Current consumption 14 A (max)
Power supply 400V 3~ 50Hz
Interfaces, Connections & Control
Controller Pilot ONE
Display resolution 0, 01 K
Digital interface Ethernet, USB (Host u. Device), RS232
Materials, Media & Process Compatibility
Maximum viscosity 50 mm²/s (max)
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C (permissible)
Protection rating IP20
Standards, Safety & General Data
Safety class III / FL

Description

Construction and series positioning

Behavior under load and media

Installation, connection and operation

Integration & Operating Notes

Electrical
Provide a site plug and 3x16 A three-phase protection

The unit is delivered with a cable but without a plug for three-phase supplies below 63 A, so the customer must fit a suitable plug. Plan the feeder for 14 A max current and 3x16 A fusing, and verify that voltage and frequency deviations do not occur simultaneously in the unfavorable combination (-5% voltage with +2% frequency is not allowed).

Datasheet, Technical Specifications; Operation Manual, Commissioning
Electrical
Account for leakage current above 3.5 mA in RCD selection

Leakage current exceeds 3.5 mA, which affects protective earthing design and residual-current device choice; a standard 30 mA RCD may nuisance-trip. The electrical installer must select and document the protective measure accordingly.

Datasheet, Technical Specifications
Process Limits
Size low-temperature duty at the actual set point, not nominal

Cooling capacity falls from 5.3 kW at 20 °C to 0.25 kW at -50 °C. A process requiring significant heat removal near the cold end must be checked against the capacity at its real operating temperature, otherwise the unit will not reach or hold set point.

Datasheet, Product Overview
Process Limits
Check loop pressure drop against 33 l/min at 2.5 bar

The pump delivers 119 l/min at zero head but only 33 l/min at 2.5 bar. High-pressure-drop processes (the reason to choose the P modification) must be evaluated against this curve; if the required flow at the loop's pressure drop is below the process demand, a different pump or piping change is needed.

Datasheet, Technical Specifications
Mounting
Reserve the full 560 x 754 x 1457 mm bay plus airflow clearance

The manufacturer explicitly requires respecting space requirements. The refrigeration machine is air-cooled, so the bay must allow heat rejection and service access; an undersized enclosure will raise ambient temperature and reduce cooling capacity, which is rated at 20 °C room temperature.

Datasheet, Technical Specifications; Operation Manual, Commissioning
Mounting
Install a drip tray and keep the unit out of ATEX zones

The responsible body must install a condensation water / heat transfer fluid drip tray below the unit, and national legislation may prescribe it. The unit must not be installed or started within an ATEX zone; explosion protection requires a separate Ex px cabinet with its own rating plate.

Operation Manual, Section 1.3.3 and 1.4
Control & I/O
Process Safety mode needs the compressor set to Permanently ON

In Process Safety mode the controller releases maximum cooling at the overtemperature trigger instead of switching off all poles. This mode requires the compressor to be set to Permanently ON; without that setting the protective behavior is not available.

Operation Manual, Setup Mode
Maintenance
Transport upright and emptied; casters are not for transport

Only transport the unit upright and emptied; horizontal transport damages the compressor and a filled unit risks thermal fluid overflow. Casters, if present, carry only 25% of total mass symmetrically and are not suitable for transport — use an industrial truck. Allow about 2 hours acclimation after a cold/warm move before power-on.

Operation Manual, Commissioning

Selection & Integration Q&A

When should I choose the Unistat P510 Dynamisches instead of the 510w or 520w water-cooled siblings?

Pick the P510 when the process loop has high pressure drop (the 'P' modification) and air cooling is acceptable in the plant room. Choose a 'w' sibling when cooling water is available and lower ambient heat rejection is needed; choose the 520w only if its higher capacity step is required.

What must I provide on the process side to connect the P510's pump, and what is not included?

The pump connection is M30x1.5 male with DIN 3863 ball socket and DIN 3870 sleeve nut mating, so hoses and fittings must match that standard. The unit ships with a cable but without a plug for the 400 V three-phase supply; the site plug and the drip tray are customer-supplied.

What ambient and duty-cycle limits apply when installing the P510 in a production hall?

Permissible ambient is 5...40 °C, and cooling capacity is rated at 20 °C and drops as ambient rises, so keep the room cool. The unit is EMC Class A Group 1 for industrial environments, must not sit in an ATEX zone, and needs the full 560 x 754 x 1457 mm bay with airflow clearance.

What maintenance and service items should be planned for, and which are not in the base delivery?

Plan periodic hose and connection inspection with replacement as needed, cleaning of condenser fins and the dirt trap, and heat transfer fluid inspection/replacement. Refrigerant work requires approved contractors. The site plug, drip tray and heat transfer fluid are not included in base delivery.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Unistat P510 Temperature Control System Datasheet
Datasheet ·83,5 КБ ·2 pp.
View PDF
PDF
Unistat® Operation Manual — Unistat® 5, Unistat® Pilot ONE®
Manual ·3,6 МБ ·100 pp.
View PDF
PDF
Unistat Operation Manual
Manual ·3,7 МБ ·102 pp.
View PDF