No photo available yet
Peter Huber Kältemaschinenbau Unistat P520 Dynamisches
Peter Huber Kältemaschinenbau Unistat P520 Dynamisches — Temperature control units.
The Unistat P520 Dynamisches is an air-cooled refrigerated heating circulator with a magnetically coupled stainless steel pump, built for high-pressure-drop circuits in flow-through chemistry and semiconductor work. Its -55 to 250 °C range and 6 kW heating capacity distinguish it from the water-cooled w-variants of the Unistat 5xx series. It serves as a temperature control source for externally closed or open applications requiring high pump discharge pressure.
Peter Huber Kältemaschinenbau Unistat Series — Model Comparison & Selection
| Model | Noise level, dB | Display resolution | Heating capacity, W | Pump connection | Pump type | Temperature range, °C |
|---|---|---|---|---|---|---|
| Unistat P520 Dynamisches Current | — | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 510w Dynamisches | 60 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat 515w Dynamisches | — | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat 520w Dynamisches | 61 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 525 Dynamisches | 56 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 525w Dynamisches | 61 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 527w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 530w Dynamisches | 59 | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 540w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 545w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 610w Dynamisches | 62 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 615w Dynamisches | 62 | 0, 01 | 12000 | M30x1, 5 AG male | Pressure pump, variable | -60–200 |
| Unistat 620w Dynamisches | 68 | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 625w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 630w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 635w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 640w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 645w Dynamisches | — | 0, 01 | 36000 | flange DN32 PN10/40 EN10 | magnetically coupled, st | -60–200 |
| Unistat 650w Dynamisches | 73 | 0, 01 | 48000 | flange DN32 PN10/40 EN10 | magnetically coupled, st | -60–200 |
| Unistat 680w Dynamisches | — | 0, 01 | 96000 | DN50 PN16 (DIN EN 1092-1 | magnetically coupled, st | -60–200 |
| Unistat GL 530w Dynamisches | 61 | 0, 01 | 6000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 535w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 540w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 550w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 560w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 570w Dynamisches | — | 0, 01 | 48000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P530w Dynamisches | 61 | 0, 01 | 6000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P535w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P540w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P550w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P560w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P570w Dynamisches | — | 0, 01 | 48000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat P510 Dynamisches | 60 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat P510w Dynamisches | 60 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat P515w Dynamisches | — | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat P520w Dynamisches | 61 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P525 Dynamisches | 56 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P525w Dynamisches | 61 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P527w Dynamisches | 57 | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P530w Dynamisches | 62 | 0.01 | 12000 | M38x1,5 AG male | magnetically coupled, st | -55–250 |
| Unistat P540w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P545w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P610 Dynamisches | — | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P610w Dynamisches | 62 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P615 Dynamisches | — | 0, 01 | 12000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P615w Dynamisches | 62 | 0, 01 | 12000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P620w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P625w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P630w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P635w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P645w Dynamisches | — | 0, 01 | 36000 | flange DN32 PN10/40 EN10 | magnetically coupled, st | -60–200 |
| Unistat P650w Dynamisches | — | 0, 01 | 48000 | flange DN32 PN10/40 EN10 | magnetically coupled, st | -60–200 |
Full specifications
| Control output | POKO ONE |
| Expansion volume | 17 l |
| Heating capacity | 6 kW |
| Pump connection | M30x1, 5 AG male |
| Pump speed adjustable | Yes |
| Pump type | magnetically coupled, stainless steel |
| External sensor connection | Pt100 |
| Temperature range | -55...250 °C |
| Power supply | 400V 3~ 50Hz |
| Controller | Pilot ONE |
| Display resolution | 0, 01 K |
| Digital interface | Ethernet, USB (Host u. Device), RS232 |
| Maximum viscosity | 50 mm²/s |
| Ambient temperature limit | 5...40 °C |
| Protection rating | IP20 |
| Safety class | III / FL |
Description
Construction and series positioning
- Air-cooled refrigerated heating circulator with optical level indicator and magnetic-coupled stainless steel circulation pump; the "P" suffix denotes the high-discharge-pressure pump variant for circuits with high pressure drop.
- Sibling models in the series include the water-cooled Unistat 510w, 515w and 520w Dynamisches and the Unistat 525 Dynamisches; this P520 is the air-cooled high-pressure-drop modification.
- Controller is Pilot ONE with POKO ONE control output, 0.01 K display resolution, and Ethernet, USB (Host and Device) and RS232 interfaces.
- Pump connection is M30x1.5 male; pump speed is adjustable.
Working range and media
- Temperature range -55 to 250 °C; heating capacity 6 kW; maximum permissible kinematic viscosity of the heat transfer fluid is 50 mm²/s.
- Minimum filling capacity 5.1 l; expansion tank volume 17 l. The expansion vessel must remain unlocked for externally closed applications and locked for externally open (bath) applications.
- Safety class III / FL; for FL-rated flammable fluids the fire point must be ≥ 65 °C, and ethanol use is permitted only under supervision.
- Cooling capacity ratings are valid at 20 °C room temperature and drop as ambient temperature rises; ambient operating range is 5 to 40 °C.
Installation, control and operation
- Factory-configured for 400 V 3~ 50 Hz; three-phase devices below 63 A are supplied with cable but without a plug. Leakage current exceeds 3.5 mA, so earthing and RCD selection must account for it.
- Voltage and frequency tolerances are linked (±5% voltage only with ±2% frequency; -5% voltage with +2% frequency is not allowed).
- EMC classification Class A, Group 1 to EN55011; IP20 protection; intended for industrial environments.
- Pilot ONE supports overtemperature protection settings (OT limit heating, OT expansion vessel, Process Safety), Delta T limiter, Pt100 monitoring, auto/expert control modes, filling/venting/degassing routines, and programmable temperature control programs.
- Power-interruption response is configurable: Off/Standby (default) or ON/Temperature control active; Process Safety mode requires the compressor set to Permanently ON.
Integration & Operating Notes
The unit is factory-configured for 400 V three-phase 50 Hz and the voltage/frequency tolerances are coupled: ±5% voltage is permitted only with ±2% frequency, and -5% voltage with +2% frequency is explicitly not allowed. Verify the site supply against this combined rule before delivery, since a mismatch cannot be corrected by a simple plug change.
The temperature control unit must not be installed or started up within an ATEX zone; without an Ex px cabinet the unit and accessories are not protected against explosion. Explosion-protected operation requires the separate ATEX annex and only the model and serial number stated on the Ex px cabinet rating plate is suitable.
The air-cooled condenser rejects heat to ambient air, so the installation room needs adequate ventilation and the room heat load must be included in HVAC planning. Cooling capacity ratings assume 20 °C room temperature and drop as ambient temperature rises; operation is permitted only between 5 and 40 °C ambient.
For externally closed applications the expansion vessel must remain unlocked; locking it will damage the application due to overpressure. For externally open (bath) applications the expansion vessel must be locked to prevent fluid loss. Confirm the application type before commissioning and set the vessel accordingly.
The maximum permissible kinematic viscosity of the heat transfer fluid is 50 mm²/s; a higher-viscosity fluid overloads the pump and reduces circulation. The minimum filling capacity is 5.1 l and the expansion tank holds 17 l, so the external circuit volume must be planned so that both the minimum fill and expansion space are satisfied.
The Pilot ONE can be configured so that after a power outage or switch-on the unit stays in Off/Standby (default, manual start required) or automatically resumes temperature control if it was active. Choose the setting according to whether unattended restart is acceptable for the process, and note that Process Safety mode requires the compressor set to Permanently ON.
Hoses and hose connections must be periodically checked for leaks and quality and replaced as required. The manual also specifies cleaning the liquefier fins, cleaning the hat-type strainer/dirt trap, emptying the drip tray, inspecting the mechanical seal, and checking/replacing the heat transfer fluid with circuit rinsing. Work on the coolant circuit must be carried out by approved refrigeration/air-conditioning contractors.
Selection & Integration Q&A
Choose the P520 when the external circuit has a high pressure drop (flow-through chemistry, semiconductor) and air cooling is acceptable. The 520w is the water-cooled equivalent for sites without room-air heat rejection capacity; the 525 is a different capacity class in the same series.
The pump connection is M30x1.5 male, so hoses or adapters must match this thread. Plan the external loop so total volume satisfies the 5.1 l minimum fill and the 17 l expansion tank, and keep fluid viscosity at or below 50 mm²/s.
Install only outside ATEX zones, at 5–40 °C ambient with ventilation for the air-cooled condenser, and on leveling feet with parking brakes engaged. Allow about 2 hours acclimation after moving between cold and warm environments before power-on.
The unit ships with cable but without a plug for three-phase supply below 63 A; the customer supplies the plug. Routine service includes hose inspection/replacement, condenser fin cleaning, strainer cleaning, drip-tray emptying and heat transfer fluid replacement; refrigerant-circuit work requires approved contractors.