No photo available yet
Peter Huber Kältemaschinenbau Unistat P520w Dynamisches
Peter Huber Kältemaschinenbau Unistat P520w Dynamisches — Temperature control units with Noise level 61 dB.
The Unistat P520w Dynamisches is a water-cooled, free-standing temperature control unit with a magnetically coupled stainless-steel circulation pump, built for the -55…250 °C range on a 400 V 3~ 50 Hz supply. Its 'P' designation marks the high-discharge-pressure pump variant (82 l/min at zero head, 3 bar max) intended for external circuits with high pressure drop. It serves flow-through chemistry and semiconductor processes where heat rejection is by cooling water at 5…20 °C.
Peter Huber Kältemaschinenbau Unistat Series — Model Comparison & Selection
| Model | Noise level, dB | Display resolution | Heating capacity, W | Pump connection | Pump type | Temperature range, °C |
|---|---|---|---|---|---|---|
| Unistat P520w Dynamisches Current | 61 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 510w Dynamisches | 60 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat 515w Dynamisches | — | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat 520w Dynamisches | 61 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 525 Dynamisches | 56 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 525w Dynamisches | 61 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 527w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 530w Dynamisches | 59 | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 540w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 545w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 610w Dynamisches | 62 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 615w Dynamisches | 62 | 0, 01 | 12000 | M30x1, 5 AG male | Pressure pump, variable | -60–200 |
| Unistat 620w Dynamisches | 68 | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 625w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 630w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 635w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 640w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 645w Dynamisches | — | 0, 01 | 36000 | flange DN32 PN10/40 EN10 | magnetically coupled, st | -60–200 |
| Unistat 650w Dynamisches | 73 | 0, 01 | 48000 | flange DN32 PN10/40 EN10 | magnetically coupled, st | -60–200 |
| Unistat 680w Dynamisches | — | 0, 01 | 96000 | DN50 PN16 (DIN EN 1092-1 | magnetically coupled, st | -60–200 |
| Unistat GL 530w Dynamisches | 61 | 0, 01 | 6000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 535w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 540w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 550w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 560w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 570w Dynamisches | — | 0, 01 | 48000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P530w Dynamisches | 61 | 0, 01 | 6000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P535w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P540w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P550w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P560w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P570w Dynamisches | — | 0, 01 | 48000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat P510 Dynamisches | 60 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat P510w Dynamisches | 60 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat P515w Dynamisches | — | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat P520 Dynamisches | — | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P525 Dynamisches | 56 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P525w Dynamisches | 61 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P527w Dynamisches | 57 | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P530w Dynamisches | 62 | 0.01 | 12000 | M38x1,5 AG male | magnetically coupled, st | -55–250 |
| Unistat P540w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P545w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P610 Dynamisches | — | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P610w Dynamisches | 62 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P615 Dynamisches | — | 0, 01 | 12000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P615w Dynamisches | 62 | 0, 01 | 12000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P620w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P625w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P630w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P635w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P645w Dynamisches | — | 0, 01 | 36000 | flange DN32 PN10/40 EN10 | magnetically coupled, st | -60–200 |
| Unistat P650w Dynamisches | — | 0, 01 | 48000 | flange DN32 PN10/40 EN10 | magnetically coupled, st | -60–200 |
Full specifications
| Noise level | 61 dB(A) (sound pressure level) |
| Control output | POKO ONE (potential-free contact) |
| Expansion volume | 16 l |
| Heating capacity | 6 kW |
| Pump connection | M30x1, 5 AG male |
| Pump speed adjustable | Yes |
| Pump type | magnetically coupled, stainless steel |
| External sensor connection | Pt100 |
| Temperature range | -55...250 °C |
| Weight | 208 kg (net) |
| Power supply | 400V 3~ 50Hz |
| Controller | Pilot ONE |
| Display resolution | 0, 01 K |
| Digital interface | Ethernet, USB (Host u. Device), RS232 |
| Maximum viscosity | 50 mm²/s (max) |
| Ambient temperature limit | 5...40 °C (permissible) |
| Cooling water connection | G1/2 male |
| Cooling water differential pressure | 1 bar (min) |
| Cooling Water Pressure | 6 bar (max) |
| Protection rating | IP20 |
| Safety class | III / FL |
Description
Construction and series positioning
- Free-standing water-cooled ('w') Unistat with a 6 kW heater, 16 l expansion volume and 208 kg net mass; overall dimensions 540x604x1332 mm.
- The 'P' suffix is the defining modification: a high-pressure circulation pump (magnetically coupled, stainless steel, speed-adjustable) for applications with high pressure drops such as flow-through chemistry or the semiconductor industry. Sibling Unistat 5xx 'Dynamisches' models without the P prefix share the dynamic temperature-control concept but not this pump emphasis.
- Controller is Pilot ONE with POKO ONE potential-free contact output; interfaces are Ethernet, USB (host and device) and RS232; external sensor input is Pt100; display resolution 0.01 K.
- Safety class III / FL; protection rating IP20; sound pressure level 61 dB(A).
Behavior under load
- Cooling capacity with ethanol falls steeply at low temperature: 6 kW at 0 °C, 4.2 kW at -20 °C, 1.5 kW at -40 °C and 0.65 kW at -50 °C. Low-temperature duty must therefore be checked against the actual process heat load.
- Pump delivery is 82 l/min at zero head, 75 l/min at 0.5 bar, 66 l/min at 1.0 bar and 32 l/min at 2.5 bar, with a maximum delivery pressure of 3 bar. External loop pressure drop must be matched to this curve.
- Heat rejection is water-based: G1/2 male cooling-water connection, minimum 1 bar differential pressure, maximum 6 bar, about 492 l/h at 15 °C water and 20 °C flow. Intake water is specified between 5 °C and 20 °C; pipes must be insulated if water can fall below the condensation point.
Installation, control and operation
- Electrical: 400 V 3~ 50 Hz, maximum current 14.5 A, 3x16 A fuse; supplied with cable but without plug (three-phase devices below 63 A). Leakage current exceeds 3.5 mA, so earthing and RCD design must account for it. Voltage and frequency tolerances are ±5% and ±2% but may not combine in the same direction.
- Ambient range 5…40 °C; EMC class A, group 1 (industrial environment).
- Pump connections are M30x1.5 male with bore shape Y (60°) per DIN 3863; mating ball socket per DIN 3863 and sleeve nut per DIN 3870 must be provided.
- Refrigerant R-452A, charge 1.44 kg, GWP 2141, 3.1 t CO2 equivalent — relevant for leak management and environmental compliance.
Integration & Operating Notes
Below 1 bar differential pressure the specified heat rejection is not available; above 6 bar the circuit is overstressed. Intake water is specified between 5 °C and 20 °C, and if the water can drop below the condensation point the cooling-water pipes inside the unit must be insulated to prevent condensation.
Horizontal transport damages the compressor, and a filled unit may overflow thermal fluid during movement. Casters, if present, are not for transport and carry only 25% of total mass symmetrically; use an industrial truck. Leveling feet must be activated and parking brakes engaged before commissioning.
Pilot ONE can be set to 'Off/Standby' (default, manual start after power returns) or 'ON/Temperature control active' (automatic restart, with a brief INFO window to abort). Power Failure Auto resumes the process automatically if temperature control was active during the outage — acceptable only where unattended restart is safe.
In Process safety mode the controller releases maximum cooling capacity at the overtemperature trigger instead of switching off all poles. This keeps heat extraction available under exothermic conditions but only works with the compressor configured to Permanently ON, so the controller setup must be verified before relying on this protection.
The cooling water supply should be closed for short downtimes such as overnight to avoid water damage and unnecessary load on the cooling circuit. Hoses and hose connections must be checked periodically for leaks and quality and replaced as required.
The unit must not be installed or started inside an ATEX zone without an Ex px cabinet, and use with medical devices (e.g. in vitro diagnostics) or for direct foodstuff temperature control is not permissible. The responsible body must also provide a condensation-water/heat-transfer-fluid drip tray below the unit.
Selection & Integration Q&A
Pick the P520w when the external circuit has high pressure drop — flow-through chemistry or semiconductor applications — because its pump delivers 82 l/min at zero head and still 32 l/min at 2.5 bar. For low-resistance loops the standard 520w pump is sufficient and avoids the higher pump stress.
A G1/2 male cooling-water supply at 5–20 °C intake, 1–6 bar differential pressure and about 492 l/h at 15 °C, plus M30x1.5 male pump connections requiring ball socket per DIN 3863 and sleeve nut per DIN 3870. Insulate cooling-water pipes if water can fall below the condensation point.
Ambient must stay 5–40 °C, the unit must not sit in an ATEX zone, and it must be transported and stored upright and moved only when emptied. Allow about 2 hours acclimation after a cold-to-warm move before power-on, and provide a drip tray below the unit.
The site plug, mating hoses and DIN 3863/3870 fittings, heat transfer fluid, and the drip tray are not part of the unit. Periodic tasks include checking and replacing hoses, cleaning liquefier fins and the dirt trap, and refrigerant work by an approved contractor; cooling water should be shut off overnight.