No photo available yet

Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau Unistat P620w Dynamisches

Peter Huber Kältemaschinenbau Unistat P620w Dynamisches — Temperature control units.

The Unistat P620w Dynamisches is a water-cooled, high-pressure-drop circulating temperature control unit with a magnetically coupled stainless-steel pump, covering -60 to 200 °C with 12 kW heating. Its 'P' designation targets applications with high pressure drop, distinguishing it from the standard 5xx/6xx siblings. It serves as a dynamic heating/cooling source for externally closed process circuits requiring three-phase power and facility cooling water.

Peter Huber Kältemaschinenbau Unistat Series — Model Comparison & Selection

Model Noise level, dBDisplay resolutionHeating capacity, WPump connectionPump typeTemperature range, °C
Unistat P620w Dynamisches Current —0, 0112000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat 510w Dynamisches 600, 016000M30x1, 5 AG malemagnetically coupled, st-50–250
Unistat 515w Dynamisches —0, 016000M30x1, 5 AG malemagnetically coupled, st-50–250
Unistat 520w Dynamisches 610, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat 525 Dynamisches 560, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat 525w Dynamisches 610, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat 527w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat 530w Dynamisches 590, 0112000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat 540w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat 545w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat 610w Dynamisches 620, 016000M30x1, 5 AG malemagnetically coupled, st-60–200
Unistat 615w Dynamisches 620, 0112000M30x1, 5 AG malePressure pump, variable -60–200
Unistat 620w Dynamisches 680, 0112000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat 625w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat 630w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat 635w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat 640w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat 645w Dynamisches —0, 0136000flange DN32 PN10/40 EN10magnetically coupled, st-60–200
Unistat 650w Dynamisches 730, 0148000flange DN32 PN10/40 EN10magnetically coupled, st-60–200
Unistat 680w Dynamisches —0, 0196000DN50 PN16 (DIN EN 1092-1magnetically coupled, st-60–200
Unistat GL 530w Dynamisches 610, 016000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL 535w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL 540w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL 550w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL 560w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL 570w Dynamisches —0, 0148000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P530w Dynamisches 610, 016000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P535w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P540w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P550w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P560w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P570w Dynamisches —0, 0148000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat P510 Dynamisches 600, 016000M30x1, 5 AG malemagnetically coupled, st-50–250
Unistat P510w Dynamisches 600, 016000M30x1, 5 AG malemagnetically coupled, st-50–250
Unistat P515w Dynamisches —0, 016000M30x1, 5 AG malemagnetically coupled, st-50–250
Unistat P520 Dynamisches —0, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat P520w Dynamisches 610, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat P525 Dynamisches 560, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat P525w Dynamisches 610, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat P527w Dynamisches 570, 0112000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat P530w Dynamisches 620.0112000M38x1,5 AG malemagnetically coupled, st-55–250
Unistat P540w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat P545w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat P610 Dynamisches —0, 016000M30x1, 5 AG malemagnetically coupled, st-60–200
Unistat P610w Dynamisches 620, 016000M30x1, 5 AG malemagnetically coupled, st-60–200
Unistat P615 Dynamisches —0, 0112000M30x1, 5 AG malemagnetically coupled, st-60–200
Unistat P615w Dynamisches 620, 0112000M30x1, 5 AG malemagnetically coupled, st-60–200
Unistat P625w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat P630w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat P635w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat P645w Dynamisches —0, 0136000flange DN32 PN10/40 EN10magnetically coupled, st-60–200
Unistat P650w Dynamisches —0, 0148000flange DN32 PN10/40 EN10magnetically coupled, st-60–200

Full specifications

Core Performance & Functional Specifications
Control output POKO ONE
Heating capacity 12 kW
Pump connection M38x1, 5 AG male
Pump speed adjustable Yes
Pump type magnetically coupled, stainless steel
External sensor connection Pt100
Temperature range -60...200 °C
Electrical, Power & Drive Specifications
Power supply 400V 3~ 50Hz
Interfaces, Connections & Control
Controller Pilot ONE
Display resolution 0, 01 K
Digital interface Ethernet, USB (Host u. Device), RS232
Materials, Media & Process Compatibility
Maximum viscosity 100 mm²/s
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C
Cooling water connection G3/4 male
Cooling water differential pressure 1 bar (min)
Cooling Water Pressure 6 bar (max)
Protection rating IP20
Standards, Safety & General Data
Safety class III / FL

Description

Construction and series positioning

Working envelope and behavior

Installation, connection and control

Integration & Operating Notes

Cooling & Media
Facility cooling water must meet pressure and temperature limits

Cooling water is connected via G3/4 male and must be supplied at 1–4 bar differential pressure and no more than 6 bar, with inlet temperature between 5 °C and 20 °C; lower inlet temperatures require insulating the cooling water pipes. The cooling water circuit contains copper, stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM, so water quality must be suitable to avoid corrosion and fouling.

Unistat P620w Technical Data, page 2
Process Limits
Fluid viscosity above 100 mm²/s overloads the pump

The maximum permissible kinematic viscosity of the heat transfer fluid is 100 mm²/s; exceeding it can overload the magnetically coupled pump and reduce flow. Fluid selection at low temperatures must respect this limit, and for FL-rated fluids the fire point must be ≥65 °C, with ethanol permitted only under supervised operation.

Unistat P620w Technical Data, page 2; Unistat Operation Manual, Section 1.7
Mounting
Never install or start the unit inside an ATEX zone

The unit must not be installed or started within an ATEX zone; explosion protection requires a separate Ex px cabinet and only the model/serial number stated on that cabinet's rating plate is suitable. The refrigerant R-1270 (A3, H220) is flammable, which affects site safety classification and handling procedures.

Unistat Operation Manual, Section 1.3.3 / page 15-16; Unistat P620w Technical Data, page 1
Control & I/O
Configure restart behavior for unattended operation

After a power outage or switch-on, the Pilot ONE can be set to 'Off/Standby' (default, manual start required) or 'ON/Temperature control active' (automatic restart with a brief INFO allowing cancellation). Choose according to whether unattended restart is acceptable for the process; Process Safety mode additionally requires the compressor set to Permanently ON.

Unistat Operation Manual, Section 1.8.1 / page 21; Section 1.7.2 / page 20
Maintenance
Shut off cooling water even for overnight downtime

The cooling water supply should be shut off even for short downtimes such as overnight to prevent water damage and unnecessary load on the circuit. Hoses and connections must be periodically checked for leaks and quality and replaced as needed; work on the coolant circuit must be carried out by approved refrigeration/air-conditioning contractors.

Unistat Operation Manual, page 29; Section 1.4.2 / page 19

Selection & Integration Q&A

When should I choose the P620w Dynamisches over the Unistat 510w or 520w Dynamisches siblings?

Pick the P620w when the application has high pressure drop (the 'P' designation) and needs the -60 to 200 °C range with 12 kW heating. The 510w/520w are different capacity points in the series; confirm the required cooling capacity at your lowest process temperature, since the P620w delivers only 1.4 kW at -60 °C with ethanol.

What must I provide on site for the electrical and cooling-water connections?

A 400 V 3~ 50 Hz supply with a site-fitted plug (unit ships with cable, no plug below 63 A) and voltage/frequency within ±5%/±2%. Cooling water via G3/4 male at 1–4 bar differential and max 6 bar, inlet 5–20 °C. Process hoses must match the M38x1.5 male pump connection.

What mounting and environment limits apply from the manual?

Install indoors, dry, IP20, ambient 5–40 °C, never in an ATEX zone. Transport and store upright only; allow ~2 h acclimation after temperature changes before power-on. Activate leveling feet/parking brakes, and install a drip tray below the unit as required by local regulations.

What maintenance and consumables are needed, and what is not included in base delivery?

Periodically inspect/replace heat transfer fluid and hoses, clean liquefier fins and the dirt trap, and test the emergency stop. The power plug, cooling-water hoses, heat transfer fluid and drip tray are not part of base delivery; refrigerant-circuit work requires approved contractors.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Unistat P620w Technical Data
Datasheet ·31,2 КБ ·2 pp.
View PDF
PDF
Unistat® Operation Manual — Unistat® 5, Unistat® Pilot ONE®
Manual ·3,6 МБ ·100 pp.
View PDF
PDF
Unistat Operation Manual
Manual ·3,7 МБ ·102 pp.
View PDF