Peter Huber Kältemaschinenbau Unistat P625w Dynamisches
Peter Huber Kältemaschinenbau Unistat P625w Dynamisches — Temperature control units.
The Unistat P625w Dynamisches is a water-cooled, free-standing temperature control system with a magnetically coupled stainless-steel pump and Pilot ONE controller, covering -60 to 200 °C with 12 kW heating. Its 'P' designation targets applications with high pressure drop, distinguishing it from the air-cooled and standard-flow siblings in the Unistat 5xx/6xx series. It serves as a circulation source for externally closed or open tempering circuits in process and pilot-plant duty.
Peter Huber Kältemaschinenbau Unistat Series — Model Comparison & Selection
| Model | Noise level, dB | Display resolution | Heating capacity, W | Pump connection | Pump type | Temperature range, °C |
|---|---|---|---|---|---|---|
| Unistat P625w Dynamisches Current | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 510w Dynamisches | 60 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat 515w Dynamisches | — | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat 520w Dynamisches | 61 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 525 Dynamisches | 56 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 525w Dynamisches | 61 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 527w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 530w Dynamisches | 59 | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 540w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 545w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 610w Dynamisches | 62 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 615w Dynamisches | 62 | 0, 01 | 12000 | M30x1, 5 AG male | Pressure pump, variable | -60–200 |
| Unistat 620w Dynamisches | 68 | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 625w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 630w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 635w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 640w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 645w Dynamisches | — | 0, 01 | 36000 | flange DN32 PN10/40 EN10 | magnetically coupled, st | -60–200 |
| Unistat 650w Dynamisches | 73 | 0, 01 | 48000 | flange DN32 PN10/40 EN10 | magnetically coupled, st | -60–200 |
| Unistat 680w Dynamisches | — | 0, 01 | 96000 | DN50 PN16 (DIN EN 1092-1 | magnetically coupled, st | -60–200 |
| Unistat GL 530w Dynamisches | 61 | 0, 01 | 6000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 535w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 540w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 550w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 560w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 570w Dynamisches | — | 0, 01 | 48000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P530w Dynamisches | 61 | 0, 01 | 6000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P535w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P540w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P550w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P560w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P570w Dynamisches | — | 0, 01 | 48000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat P510 Dynamisches | 60 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat P510w Dynamisches | 60 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat P515w Dynamisches | — | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat P520 Dynamisches | — | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P520w Dynamisches | 61 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P525 Dynamisches | 56 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P525w Dynamisches | 61 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P527w Dynamisches | 57 | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P530w Dynamisches | 62 | 0.01 | 12000 | M38x1,5 AG male | magnetically coupled, st | -55–250 |
| Unistat P540w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P545w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P610 Dynamisches | — | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P610w Dynamisches | 62 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P615 Dynamisches | — | 0, 01 | 12000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P615w Dynamisches | 62 | 0, 01 | 12000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P620w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P630w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P635w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P645w Dynamisches | — | 0, 01 | 36000 | flange DN32 PN10/40 EN10 | magnetically coupled, st | -60–200 |
| Unistat P650w Dynamisches | — | 0, 01 | 48000 | flange DN32 PN10/40 EN10 | magnetically coupled, st | -60–200 |
Full specifications
| Control output | POKO ONE |
| Heating capacity | 12 kW |
| Pump connection | M38x1, 5 AG male |
| Pump speed adjustable | Yes |
| Pump type | magnetically coupled, stainless steel |
| External sensor connection | Pt100 |
| Temperature range | -60...200 °C |
| Power supply | 400V 3~ 50Hz |
| Controller | Pilot ONE |
| Display resolution | 0, 01 K |
| Digital interface | Ethernet, USB (Host u. Device), RS232 |
| Maximum viscosity | 100 mm²/s |
| Ambient temperature limit | 5...40 °C |
| Cooling water connection | G3/4 male |
| Cooling water differential pressure | 1 bar (min) |
| Cooling Water Pressure | 6 bar (max) |
| Protection rating | IP20 |
| Safety class | III / FL |
Description
Construction and series positioning
- Free-standing water-cooled unit (suffix 'w') with a 918x963x1771 mm footprint, IP20 enclosure, and 400 V 3~ 50 Hz supply.
- The 'P' in P625w marks the high-pressure-drop variant: the magnetically coupled stainless-steel pump delivers up to 201 l/min at zero head and 42 l/min at 5 bar, so it is chosen where the external circuit (narrow bores, long hoses, plate exchangers) would starve a standard pump.
- Sibling models in the Dynamisches family (510w, 515w, 520w, 525) differ in cooling capacity and noise level; the P625w is the high-head member, not a larger-capacity one.
- Pump connection is M38x1.5 male with Y-bore per DIN 3863; mating hoses require ball socket DIN 3863 and sleeve nut DIN 3870.
Working range and media behavior
- Temperature range -60 to 200 °C, display resolution 0.01 K, external Pt100 sensor input for process-side control.
- Heating capacity 12 kW; cooling is water-side, with cooling water intake designed for 5–20 °C and 1–4 bar differential (max 6 bar).
- Cooling capacity is rated at 20 °C room, 15 °C cooling water inlet, 1 bar differential; site conditions away from this will shift available capacity.
- Heat transfer fluid must not exceed 100 mm²/s kinematic viscosity at operating temperature; the cooling water circuit contains copper, 1.4401 stainless, MS, PA, PPE, PTFE and EPDM, so water quality must be compatible.
- Refrigerant R-452A (A1, H280, GWP 2141) requires leak detection and certified refrigerant handling.
Control, installation and operation
- Pilot ONE controller with POKO ONE control output; interfaces Ethernet, USB host/device and RS232; pump speed adjustable.
- Safety class III/FL; overtemperature protection settable for heating and expansion vessel, with a 'Process safety' mode that applies maximum cooling at the OT trigger instead of all-pole switch-off (requires compressor set to Permanently ON).
- Expansion vessel must remain unlocked for externally closed applications and locked for externally open (bath) applications.
- Three-phase units below 63 A ship with cable but without plug; hard-wiring must be by an electrician, and the -5% voltage / +2% frequency combination is not permitted.
- Unit must be transported upright and emptied, acclimated ~2 h after cold/warm moves, and installed outside ATEX zones with a drip tray beneath it.
Integration & Operating Notes
Below 1 bar differential the condenser cannot reject rated heat; above 4 bar differential or 6 bar static the water circuit is overstressed. Fit a pressure regulator or check valve on the building cooling loop and verify the differential at commissioning, not just the supply pressure.
The supply envelope is ±5% voltage and ±2% frequency, but the specific combination of -5% voltage and +2% frequency is explicitly not allowed. Site power quality studies should check both parameters together, since a brownout during a frequency excursion can push the compressor and electronics outside the permitted envelope.
For externally closed applications the expansion vessel must remain unlocked; locking it causes overpressure damage to the application. For externally open (bath) applications it must be locked to prevent fluid loss. Confirm the application type before commissioning and set the isolating sleeve/valve accordingly.
In 'Process safety' mode the controller releases maximum cooling at the OT trigger rather than switching off all poles. This only works if the compressor is configured to Permanently ON; otherwise the protective cooling action is not available. Verify this setting during setup and document it in the process risk assessment.
The manual directs shutting off the cooling water supply even for short downtimes such as overnight. This prevents water damage from undetected leaks and avoids unnecessary load on the building cooling circuit. Include the cooling water shut-off valve in the daily shutdown checklist.
The unit must not be installed or started within an ATEX zone; explosion protection requires a separate Ex px cabinet with its own rating plate. The responsible body must also install a condensation water / heat transfer fluid drip tray below the unit, as national legislation may prescribe it.
Selection & Integration Q&A
Pick the P625w when the external circuit has high pressure drop (narrow bores, long hoses, plate exchangers) and needs the high-head pump: 201 l/min at zero head, 42 l/min at 5 bar. The 520w/525 are standard-flow siblings; choose them when head is not the constraint and lower noise (56–61 dB(A)) matters.
Pump connection is M38x1.5 male with Y-bore per DIN 3863; use ball socket DIN 3863 and sleeve nut DIN 3870 hoses. Cooling water connection is G3/4 male, supplied at 5–20 °C with 1–4 bar differential (max 6 bar). Three-phase units below 63 A ship with cable but no plug.
Install outside ATEX zones, 5–40 °C ambient, IP20, with a drip tray beneath. Transport upright and emptied; allow ~2 h acclimation after cold/warm moves. Leveling feet and caster brakes must be set before start-up. Cooling water should be shut off even overnight.
Base delivery excludes the power plug (three-phase <63 A), mating hoses/fittings, drip tray, and heat transfer fluid. Periodic tasks include hose/connection inspection and replacement, liquefier fin cleaning, hat-type strainer cleaning, and fluid inspection/replacement. Refrigerant work requires approved contractors.