No photo available yet

Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau Unistat P625w Dynamisches

Peter Huber Kältemaschinenbau Unistat P625w Dynamisches — Temperature control units.

The Unistat P625w Dynamisches is a water-cooled, free-standing temperature control system with a magnetically coupled stainless-steel pump and Pilot ONE controller, covering -60 to 200 °C with 12 kW heating. Its 'P' designation targets applications with high pressure drop, distinguishing it from the air-cooled and standard-flow siblings in the Unistat 5xx/6xx series. It serves as a circulation source for externally closed or open tempering circuits in process and pilot-plant duty.

Peter Huber Kältemaschinenbau Unistat Series — Model Comparison & Selection

Model Noise level, dBDisplay resolutionHeating capacity, WPump connectionPump typeTemperature range, °C
Unistat P625w Dynamisches Current —0, 0112000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat 510w Dynamisches 600, 016000M30x1, 5 AG malemagnetically coupled, st-50–250
Unistat 515w Dynamisches —0, 016000M30x1, 5 AG malemagnetically coupled, st-50–250
Unistat 520w Dynamisches 610, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat 525 Dynamisches 560, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat 525w Dynamisches 610, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat 527w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat 530w Dynamisches 590, 0112000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat 540w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat 545w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat 610w Dynamisches 620, 016000M30x1, 5 AG malemagnetically coupled, st-60–200
Unistat 615w Dynamisches 620, 0112000M30x1, 5 AG malePressure pump, variable -60–200
Unistat 620w Dynamisches 680, 0112000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat 625w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat 630w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat 635w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat 640w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat 645w Dynamisches —0, 0136000flange DN32 PN10/40 EN10magnetically coupled, st-60–200
Unistat 650w Dynamisches 730, 0148000flange DN32 PN10/40 EN10magnetically coupled, st-60–200
Unistat 680w Dynamisches —0, 0196000DN50 PN16 (DIN EN 1092-1magnetically coupled, st-60–200
Unistat GL 530w Dynamisches 610, 016000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL 535w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL 540w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL 550w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL 560w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL 570w Dynamisches —0, 0148000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P530w Dynamisches 610, 016000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P535w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P540w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P550w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P560w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P570w Dynamisches —0, 0148000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat P510 Dynamisches 600, 016000M30x1, 5 AG malemagnetically coupled, st-50–250
Unistat P510w Dynamisches 600, 016000M30x1, 5 AG malemagnetically coupled, st-50–250
Unistat P515w Dynamisches —0, 016000M30x1, 5 AG malemagnetically coupled, st-50–250
Unistat P520 Dynamisches —0, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat P520w Dynamisches 610, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat P525 Dynamisches 560, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat P525w Dynamisches 610, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat P527w Dynamisches 570, 0112000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat P530w Dynamisches 620.0112000M38x1,5 AG malemagnetically coupled, st-55–250
Unistat P540w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat P545w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat P610 Dynamisches —0, 016000M30x1, 5 AG malemagnetically coupled, st-60–200
Unistat P610w Dynamisches 620, 016000M30x1, 5 AG malemagnetically coupled, st-60–200
Unistat P615 Dynamisches —0, 0112000M30x1, 5 AG malemagnetically coupled, st-60–200
Unistat P615w Dynamisches 620, 0112000M30x1, 5 AG malemagnetically coupled, st-60–200
Unistat P620w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat P630w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat P635w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat P645w Dynamisches —0, 0136000flange DN32 PN10/40 EN10magnetically coupled, st-60–200
Unistat P650w Dynamisches —0, 0148000flange DN32 PN10/40 EN10magnetically coupled, st-60–200

Full specifications

Core Performance & Functional Specifications
Control output POKO ONE
Heating capacity 12 kW
Pump connection M38x1, 5 AG male
Pump speed adjustable Yes
Pump type magnetically coupled, stainless steel
External sensor connection Pt100
Temperature range -60...200 °C
Electrical, Power & Drive Specifications
Power supply 400V 3~ 50Hz
Interfaces, Connections & Control
Controller Pilot ONE
Display resolution 0, 01 K
Digital interface Ethernet, USB (Host u. Device), RS232
Materials, Media & Process Compatibility
Maximum viscosity 100 mm²/s
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C
Cooling water connection G3/4 male
Cooling water differential pressure 1 bar (min)
Cooling Water Pressure 6 bar (max)
Protection rating IP20
Standards, Safety & General Data
Safety class III / FL

Description

Construction and series positioning

Working range and media behavior

Control, installation and operation

Integration & Operating Notes

Process Limits
Cooling water differential must stay within 1–4 bar

Below 1 bar differential the condenser cannot reject rated heat; above 4 bar differential or 6 bar static the water circuit is overstressed. Fit a pressure regulator or check valve on the building cooling loop and verify the differential at commissioning, not just the supply pressure.

Unistat P625w Technical Data, page 2
Electrical
Do not combine -5% voltage with +2% frequency

The supply envelope is ±5% voltage and ±2% frequency, but the specific combination of -5% voltage and +2% frequency is explicitly not allowed. Site power quality studies should check both parameters together, since a brownout during a frequency excursion can push the compressor and electronics outside the permitted envelope.

Unistat P625w Technical Data, page 2
Mounting
Expansion vessel lock state depends on open vs closed circuit

For externally closed applications the expansion vessel must remain unlocked; locking it causes overpressure damage to the application. For externally open (bath) applications it must be locked to prevent fluid loss. Confirm the application type before commissioning and set the isolating sleeve/valve accordingly.

Unistat Operation Manual, Section on Preparations for Operation, page 33
Control & I/O
Process safety mode needs compressor set to Permanently ON

In 'Process safety' mode the controller releases maximum cooling at the OT trigger rather than switching off all poles. This only works if the compressor is configured to Permanently ON; otherwise the protective cooling action is not available. Verify this setting during setup and document it in the process risk assessment.

Unistat Operation Manual, Section 1.7.2 / page 19-20
Maintenance
Shut off cooling water even for overnight downtime

The manual directs shutting off the cooling water supply even for short downtimes such as overnight. This prevents water damage from undetected leaks and avoids unnecessary load on the building cooling circuit. Include the cooling water shut-off valve in the daily shutdown checklist.

Unistat Operation Manual, page 29
Mounting
Install outside ATEX zones and provide a drip tray

The unit must not be installed or started within an ATEX zone; explosion protection requires a separate Ex px cabinet with its own rating plate. The responsible body must also install a condensation water / heat transfer fluid drip tray below the unit, as national legislation may prescribe it.

Unistat Operation Manual, Section 1.3.3 / page 15-17

Selection & Integration Q&A

When should I choose the P625w over the 520w or 525 Dynamisches siblings?

Pick the P625w when the external circuit has high pressure drop (narrow bores, long hoses, plate exchangers) and needs the high-head pump: 201 l/min at zero head, 42 l/min at 5 bar. The 520w/525 are standard-flow siblings; choose them when head is not the constraint and lower noise (56–61 dB(A)) matters.

What mating fittings and cooling water supply does the P625w require from adjacent systems?

Pump connection is M38x1.5 male with Y-bore per DIN 3863; use ball socket DIN 3863 and sleeve nut DIN 3870 hoses. Cooling water connection is G3/4 male, supplied at 5–20 °C with 1–4 bar differential (max 6 bar). Three-phase units below 63 A ship with cable but no plug.

What installation and duty-cycle limits apply to the P625w from the manual?

Install outside ATEX zones, 5–40 °C ambient, IP20, with a drip tray beneath. Transport upright and emptied; allow ~2 h acclimation after cold/warm moves. Leveling feet and caster brakes must be set before start-up. Cooling water should be shut off even overnight.

What maintenance and consumables are not included in base delivery for the P625w?

Base delivery excludes the power plug (three-phase <63 A), mating hoses/fittings, drip tray, and heat transfer fluid. Periodic tasks include hose/connection inspection and replacement, liquefier fin cleaning, hat-type strainer cleaning, and fluid inspection/replacement. Refrigerant work requires approved contractors.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Unistat P625w Technical Data
Datasheet ·18,8 КБ ·2 pp.
View PDF
PDF
Unistat® Operation Manual — Unistat® 5, Unistat® Pilot ONE®
Manual ·3,6 МБ ·100 pp.
View PDF
PDF
Unistat Operation Manual
Manual ·3,7 МБ ·102 pp.
View PDF