Peter Huber Kältemaschinenbau Unistat P650w Dynamisches
Peter Huber Kältemaschinenbau Unistat P650w Dynamisches — Temperature control units.
The Unistat P650w Dynamisches is a water-cooled, free-standing temperature control unit with a magnetically coupled stainless-steel pump and DN32 PN10/40 flanges, covering -60 to 200 °C with 48 kW heating. It is the high-capacity water-cooled modification in the Unistat 5xx/6xx series, distinguished by its 100 A three-phase supply and 5000 l/h cooling-water demand. It serves as a central temperature source for large externally closed or open processes requiring dynamic temperature control.
Peter Huber Kältemaschinenbau Unistat Series — Model Comparison & Selection
| Model | Noise level, dB | Display resolution | Heating capacity, W | Pump connection | Pump type | Temperature range, °C |
|---|---|---|---|---|---|---|
| Unistat P650w Dynamisches Current | — | 0, 01 | 48000 | flange DN32 PN10/40 EN10 | magnetically coupled, st | -60–200 |
| Unistat 510w Dynamisches | 60 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat 515w Dynamisches | — | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat 520w Dynamisches | 61 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 525 Dynamisches | 56 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 525w Dynamisches | 61 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 527w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 530w Dynamisches | 59 | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 540w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 545w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 610w Dynamisches | 62 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 615w Dynamisches | 62 | 0, 01 | 12000 | M30x1, 5 AG male | Pressure pump, variable | -60–200 |
| Unistat 620w Dynamisches | 68 | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 625w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 630w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 635w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 640w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 645w Dynamisches | — | 0, 01 | 36000 | flange DN32 PN10/40 EN10 | magnetically coupled, st | -60–200 |
| Unistat 650w Dynamisches | 73 | 0, 01 | 48000 | flange DN32 PN10/40 EN10 | magnetically coupled, st | -60–200 |
| Unistat 680w Dynamisches | — | 0, 01 | 96000 | DN50 PN16 (DIN EN 1092-1 | magnetically coupled, st | -60–200 |
| Unistat GL 530w Dynamisches | 61 | 0, 01 | 6000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 535w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 540w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 550w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 560w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 570w Dynamisches | — | 0, 01 | 48000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P530w Dynamisches | 61 | 0, 01 | 6000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P535w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P540w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P550w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P560w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P570w Dynamisches | — | 0, 01 | 48000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat P510 Dynamisches | 60 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat P510w Dynamisches | 60 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat P515w Dynamisches | — | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat P520 Dynamisches | — | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P520w Dynamisches | 61 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P525 Dynamisches | 56 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P525w Dynamisches | 61 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P527w Dynamisches | 57 | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P530w Dynamisches | 62 | 0.01 | 12000 | M38x1,5 AG male | magnetically coupled, st | -55–250 |
| Unistat P540w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P545w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P610 Dynamisches | — | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P610w Dynamisches | 62 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P615 Dynamisches | — | 0, 01 | 12000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P615w Dynamisches | 62 | 0, 01 | 12000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P620w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P625w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P630w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P635w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P645w Dynamisches | — | 0, 01 | 36000 | flange DN32 PN10/40 EN10 | magnetically coupled, st | -60–200 |
Full specifications
| Control output | POKO ONE (potential-free contact) |
| Expansion volume | 28 l |
| Filling volume | 28 l (min) |
| Heating capacity | 48 kW |
| Pump connection | flange DN32 PN10/40 EN1092-1 |
| Pump speed adjustable | Yes |
| Pump type | magnetically coupled, stainless steel |
| External sensor connection | Pt100 |
| Temperature range | -60...200 °C |
| Weight | 2500 kg (net) |
| Current consumption | 100 A (max) |
| Power supply | 400V 3~ 50Hz |
| Controller | Pilot ONE |
| Display resolution | 0, 01 K |
| Digital interface | Ethernet, USB (Host u. Device), RS232 |
| Maximum viscosity | 50 mm²/s (max permissible) |
| Ambient temperature limit | 5...40 °C (permissible) |
| Cooling water connection | flange DN32 PN10/40 EN1092-1 |
| Cooling water consumption | 5000 l/h (at 15°C, flow 0°C) |
| Cooling water differential pressure | 3 bar (min) |
| Cooling Water Pressure | 6 bar (max) |
| Protection rating | IP20 |
| Safety class | III / FL |
Description
Construction and series positioning
- Free-standing water-cooled unit (suffix 'w') with a magnetically coupled stainless-steel pump; pump speed is adjustable.
- Process and cooling-water connections are both DN32 PN10/40 EN1092-1 flanges, so mating flanges and gaskets must be procured.
- Net weight 2500 kg and overall dimensions 2210x1300x2160 mm; floor loading, transport route and rigging must be verified.
- Within the Unistat 5xx/6xx family, this is the high-capacity water-cooled variant; air-cooled siblings (e.g. Unistat 510w/520w/525 Dynamisches) differ in cooling concept and capacity, so selection hinges on available cooling water and electrical infrastructure.
Working range and behavior
- Temperature range -60 to 200 °C with 48 kW heating capacity; display resolution 0.01 K.
- Rated cooling performance is valid only at 20 °C room temperature, 15 °C cooling-water inlet and 3 bar differential pressure; higher cooling-water temperature reduces cooling power and may require increased flow.
- Cooling water must be supplied at 5–20 °C with 3–6 bar differential pressure and about 5000 l/h at 15 °C.
- Maximum permissible viscosity of the heat transfer fluid is 50 mm²/s; filling volume minimum 28 l, expansion volume 28 l.
- Refrigerant R-507, charge 26.5 kg (105.6 t CO2 equivalent); water-cooled condenser.
Control, installation and operation
- Pilot ONE controller with POKO ONE potential-free contact; interfaces Ethernet, USB (Host and Device) and RS232; external Pt100 sensor connection.
- Power supply 400 V 3~ 50 Hz, max current 100 A, fusing 3x125 A; three-phase devices above 63 A are supplied without cable and without plug, so the customer must provide the power connection.
- Leakage current exceeds 3.5 mA; protective earthing and RCD selection must account for this.
- IP20 protection, ambient 5–40 °C; Class A, Group 1 EMC classification for industrial environments.
- Safety class III / FL; for FL-rated flammable fluids the fire point must be ≥65 °C, and ethanol use requires supervised operation.
- Cooling-water pipes must be insulated when water temperature falls below the condensation point.
- The unit must not be installed in an ATEX zone; medical-device and direct-food applications are not permissible.
Integration & Operating Notes
The 400 V 3~ 50 Hz supply must deliver up to 100 A and be protected with 3x125 A fuses; voltage tolerance is ±5% with simultaneous frequency tolerance ±2%, but not in the unfavorable combination. Because current exceeds 63 A, the unit arrives without cable and plug, so the installer must provide a hard-wired connection by an electrician.
The facility water system must supply 5–20 °C water at 3–6 bar differential pressure and about 5000 l/h at 15 °C. Higher cooling-water temperature reduces cooling power and may require increased flow, so design the water supply with margin. Insulate cooling-water pipes when water temperature falls below the condensation point.
The 2500 kg unit must be transported and stored upright only; horizontal transport damages the compressor. Only an emptied unit may be moved. Casters, if present, are not suitable for transport and carry only 25% of total mass symmetrically; use an industrial truck. Leveling feet must be activated and parking brakes engaged before commissioning.
For externally closed applications the expansion vessel must remain unlocked; locking it causes overpressure damage to the application. For externally open (bath) applications the expansion vessel must be locked to prevent fluid loss. Verify the correct state before filling and venting.
In Process Safety mode the controller releases maximum cooling capacity at the overtemperature trigger instead of switching off all poles; this requires the compressor to be set to Permanently ON. Configure the Pilot ONE accordingly when exothermic reactions or glass breakage risk must be mitigated.
Shut off the cooling water supply to the unit even for shorter downtimes such as overnight to prevent water damage and unnecessary load on the cooling circuit. Periodically check hoses and connections for leaks and quality and replace as required. Refrigerant-circuit work must be carried out by approved refrigeration/air-conditioning contractors.
Selection & Integration Q&A
Choose the P650w when a large cooling-water supply (5–20 °C, 3–6 bar, ~5000 l/h) and a 400 V/100 A feed are available and high heating capacity (48 kW) over -60 to 200 °C is needed. Air-cooled siblings avoid water infrastructure but differ in capacity and cooling concept.
Provide DN32 PN10/40 EN1092-1 mating flanges and gaskets for both pump and cooling-water connections, a hard-wired 400 V 3~ 50 Hz supply with 3x125 A fusing (no cable or plug supplied above 63 A), and a cooling-water system delivering 5–20 °C at 3–6 bar and ~5000 l/h. Account for leakage current >3.5 mA in earthing and RCD selection.
Install indoors, not in an ATEX zone, with 5–40 °C ambient and IP20 protection. Transport upright and empty; use an industrial truck, not casters. Activate leveling feet and parking brakes. Allow ~2 h acclimation after moving between cold and warm environments before power-on.
Base delivery excludes power cable and plug (above 63 A), mating flanges/gaskets, and heat transfer fluid. Plan periodic hose/connection inspection and replacement, cooling-water shutoff for overnight downtimes, cleaning of liquefier fins and hat-type strainer, and refrigerant service by approved contractors (R-507, 26.5 kg).