Peter Huber Kältemaschinenbau Unichiller 030T
Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau Unichiller 030T

Peter Huber Kältemaschinenbau Unichiller 030T — Recirculating chillers with Noise level 69 dB.

The Unichiller 030T is a recirculating chiller with a Pilot ONE controller, rated for -10 to 40 °C and 460 V 3~ 60 Hz supply. It distinguishes itself within the series by its 69 dB(A) noise level, while the 030Tw variant operates at 61 dB(A). It is intended for externally closed cooling circuits in industrial processes.

Noise level
69 dB

Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection

Model Noise level, dBPump connectionPump typeSafety classTemperature range, °CPower supply
Unichiller 030T Current 69G3/4 AG maleBI / NFL-10–40460V 3~ 60Hz
Unichiller 030Tw 61G3/4 AG maleBI / NFL-20–40400V 3~ 50Hz
Unichiller 040T 69G3/4 AG maleBI / NFL-10–40400V 3~ 50Hz
Unichiller 040T-H 69G3/4 AG maleBIII / FL-10–100400V 3~ 50Hz
Unichiller 040Tw 70G3/4 AG maleBI / NFL-10–40400V 3~ 50Hz
Unichiller 040Tw-H 70G3/4 AG maleBIII / FL-10–100400V 3~ 50Hz
Unichiller 050-H 62G1 1/4 AG maleE1III / FL-20–100400V 3~ 50Hz
Unichiller 050w-H 62G1 1/4 AG maleE1III / FL-20–100460V 3~ 60Hz
Unichiller 055T —G1 1/4 AG maleC3I / NFL-20–40400V 3~ 50Hz
Unichiller 055T-H 74G1 1/4 AG maleC3III / FL-20–100400V 3~ 50Hz
Unichiller 055Tw —G1 1/4 AG maleC3I / NFL-20–40400V 3~ 50Hz
Unichiller 060T —G1 1/4 AG maleC3I / NFL-20–40400V 3~ 50Hz
Unichiller 060T-H —G1 1/4 AG maleC3III / FL-20–100400V 3~ 50Hz
Unichiller 060Tw-H —G1 1/4 AG maleC3III / FL-20–100400V 3~ 50Hz
Unichiller 070T-H 66G1 1/4 AG maleC3III / FL-10–100400V 3~ 50Hz
Unichiller 070Tw-H —G1 1/4 AG maleC3III / FL-10–100400V 3~ 50Hz
Unichiller 075w —G1 1/4 AG maleE1I / NFL-20–40400V 3~ 50Hz
Unichiller 075w-H —G1 1/4 AG maleE1III / FL-20–100400V 3~ 50Hz
Unichiller 100-H 58G1 1/4 AG maleE1III / FL-20–100460V 3~ 60Hz
Unichiller 100T —G1 1/4 AG maleC3I / NFL-20–40400V 3~ 50Hz
Unichiller 100T-H —G1 1/4 AG maleC3III / FL-20–100400V 3~ 50Hz
Unichiller 100Tw 65G1 1/4 AG maleC3I / NFL-20–40400V 3~ 50Hz
Unichiller GL 035w —G1 1/4 AG malePressure pump, speed notI / NFL-20–40460V 3~ 60Hz
Unichiller GL 050w —G1 1/4 AG malePressure pump, speed notI / NFL-20–40460V 3~ 60Hz
Unichiller GL 075 —G1 1/4 AG malePressure pump, speed notI / NFL-20–40460V 3~ 60Hz
Unichiller GL 075w —G1 1/4 AG malePressure pump, speed notI / NFL-20–40460V 3~ 60Hz
Unichiller GL 100w —G1 1/4 AG malePressure pump, speed notI / NFL-20–40400V 3~ 50Hz
Unichiller P050 62G1 1/4 AG maleE2I / NFL-20–40400V 3~ 50Hz
Unichiller P050w 62G1 1/4 AG maleE2I / NFL-20–40400V 3~ 50Hz
Unichiller P050w-H 62G1 1/4 AG maleE2III / FL-20–100—
Unichiller P075 61G1 1/4 AG maleE2I / NFL-20–40400V 3~ 50Hz
Unichiller P075w —G1 1/4 AG maleE2I / NFL-20–40400V 3~ 50Hz
Unichiller P075w-H —G1 1/4 AG maleE2III / FL-20–100400V 3~ 50Hz
Unichiller P100 —G1 1/4 AG maleE2I / NFL-20–40460V 3~ 60Hz
Unichiller P100-H —G1 1/4 AG maleE2III / FL-20–100400V 3~ 50Hz
Unichiller P100w 58G1 1/4 AG maleE2I / NFL-20–40400V 3~ 50Hz
Unichiller P100w-H 58G1 1/4 AG maleE2III / FL-20–100400V 3~ 50Hz

Full specifications

Core Performance & Functional Specifications
Noise level 69 dB(A)
Pump connection G3/4 AG male
Pump speed adjustable no
Pump type B
External sensor connection Pt100
Temperature range -10...40 °C
Dimensions, Weight & Mechanical Design
Weight 164 kg
Electrical, Power & Drive Specifications
Power supply 460V 3~ 60Hz
Interfaces, Connections & Control
Controller Pilot ONE
Digital interface Ethernet, USB (Host u. Device), RS232
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C
Protection rating IP20
Standards, Safety & General Data
Safety class I / NFL

Description

Construction and Series Positioning

The Unichiller 030T is a recirculating chiller in the Umwaelzkuehler Bis 10 Kw series. It uses refrigerant R-449A (GHS H280, GWP 1397) and is classified under Article 4.3 PED. The unit has IP20 protection and is designed for indoor installation only. Compared to its siblings, the 030T shares the 69 dB(A) noise level with the 040T and 040T-H, while the 030Tw and 030Tw-H are quieter at 61 dB(A). The 030T is therefore positioned as a standard-noise model, with quieter alternatives available in the same capacity class.

Hydraulic and Thermal Behavior

The chiller operates over a temperature range of -10 to 40 °C. The pump delivers a maximum of 31 l/min at up to 4 bar, with flow decreasing as pressure rises; the external circuit pressure drop must be matched to this pump curve. The minimum filling capacity is 3.5 l, and the expansion volume is also 3.5 l, so the external loop volume and expansion allowance must be verified. Cooling capacity is rated at 20 °C room temperature and may drop at higher ambient temperatures, requiring derating for warm rooms. The unit is intended only for externally closed applications.

Control, Installation, and Operation

The Pilot ONE controller provides Ethernet, USB (Host and Device), and RS232 interfaces. Power-failure response can be configured as OFF/Standby, ON, or Power Failure Auto. Process Safety mode releases maximum cooling capacity when the overtemperature trigger value is reached, rather than switching off all poles. Installation requires a three-phase 460 V 60 Hz supply with a 3x10 A fuse and external branch circuit protection according to UL 489. Three-phase devices under 63 A are supplied with cable but without a plug. Voltage and frequency tolerances are ±5% and ±2% respectively, but must not be combined in opposite directions. The pump connection is G3/4 male, and maximum tightening torques must not be exceeded. A wall clearance of 50 to 200 cm per side is required for maintenance. The unit must not be installed in an ATEX zone, and refrigerant charge versus room size must be checked.

Integration & Operating Notes

Electrical
Supply must meet 460 V 3~ 60 Hz with UL 489 breaker

The chiller requires a three-phase 460 V 60 Hz supply with a 3x10 A fuse. External branch circuit protection according to UL 489 is mandatory, so a suitable breaker must be included in the installation. Voltage and frequency tolerances are ±5% and ±2% respectively, but they must not be combined in opposite directions; verify supply quality before commissioning.

Unichiller 030T Technical Data, page 2
Mounting
Indoor installation with 50–200 cm side clearance required

The unit may only be used indoors at an illuminance of at least 300 lx and up to 2000 m altitude. A wall clearance of 50 to 200 cm per side is required for maintenance on free-standing models. The unit must not be installed or started up inside an ATEX zone because it is not explosion-protected. Refrigerant charge and room size must be checked to avoid exceeding the refrigerant limit per m³ of ambient air.

Unichiller Operation Manual, pages 13, 15, 25
Process Limits
External circuit volume and pressure drop must match pump curve

The pump delivers a maximum of 31 l/min at up to 4 bar, with flow dropping as pressure rises. The minimum filling capacity is 3.5 l and expansion volume is 3.5 l, so the external circuit volume and expansion allowance must be checked. The unit is intended only for externally closed applications, which constrains the hydraulic circuit design.

Unichiller 030T Technical Data, page 1; Unichiller Operation Manual, page 34
Control & I/O
Configure power-failure response and Process Safety mode

The power-failure response can be configured as OFF/Standby, ON, or Power Failure Auto via the Pilot ONE. Process Safety mode releases maximum cooling capacity when the overtemperature trigger value is reached instead of switching off all poles. This is critical for exothermic processes where cutting cooling would cause runaway temperatures.

Unichiller Operation Manual, pages 18–19

Selection & Integration Q&A

When should I choose the Unichiller 030T over the quieter 030Tw or the larger 040T?

Choose the 030T when standard noise (69 dB(A)) is acceptable and you need the -10 to 40 °C range with 460 V 3~ 60 Hz supply. The 030Tw offers 61 dB(A) for noise-sensitive areas. The 040T provides the same noise level but is a different capacity class; select it only if higher cooling capacity is required.

What are the requirements for the electrical supply and branch circuit protection for this chiller?

The 030T requires a three-phase 460 V 60 Hz supply with a 3x10 A fuse. External branch circuit protection according to UL 489 is mandatory. Three-phase devices under 63 A are supplied with cable but without a plug, so the installer must provide the final connection. Voltage and frequency tolerances are ±5% and ±2%, but must not be combined in opposite directions.

What mounting and ambient conditions must be observed for the Unichiller 030T?

Install indoors only, at 5–40 °C ambient temperature, with illuminance at least 300 lx and altitude up to 2000 m. Maintain 50–200 cm wall clearance per side for maintenance. Do not install in an ATEX zone. Ensure refrigerant charge per room volume is within limits. Leveling feet must be activated and parking brakes applied before operation.

What maintenance is required and what accessories are not included in the base delivery?

Refrigerant circuit work must be performed by approved refrigeration contractors. Monitor fluid level via the digital indicator and maintain the expansion tank. Shut off cooling water during downtimes. The base delivery includes a cable but no plug for three-phase connection; mating hoses and fittings for G3/4 male pump connection are not included. External branch circuit protection (UL 489 breaker) must be provided by the installer.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Unichiller Operation Manual
Manual ·2,8 МБ ·82 pp.
View PDF
PDF
Unichiller 030T Technical Data
Datasheet ·93,7 КБ ·2 pp.
View PDF