Peter Huber Kältemaschinenbau Unichiller 040Tw
Peter Huber Kältemaschinenbau Unichiller 040Tw — Recirculating chillers with Noise level 70 dB.
The Unichiller 040Tw is a water-cooled recirculating chiller for externally closed circuits, operating from -10 to 40 °C with a Pilot ONE controller. Its 70 dB(A) noise level and 134 kg free-standing housing distinguish it from the quieter 030Tw and the air-cooled 040T siblings. It serves as a central cooling source for laboratory and pilot-scale processes.
Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection
| Model | Noise level, dB | Pump connection | Pump type | Safety class | Temperature range, °C | Power supply |
|---|---|---|---|---|---|---|
| Unichiller 040Tw Current | 70 | G3/4 AG male | B | I / NFL | -10–40 | 400V 3~ 50Hz |
| Unichiller 030T | 69 | G3/4 AG male | B | I / NFL | -10–40 | 460V 3~ 60Hz |
| Unichiller 030Tw | 61 | G3/4 AG male | B | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller 040T | 69 | G3/4 AG male | B | I / NFL | -10–40 | 400V 3~ 50Hz |
| Unichiller 040T-H | 69 | G3/4 AG male | B | III / FL | -10–100 | 400V 3~ 50Hz |
| Unichiller 040Tw-H | 70 | G3/4 AG male | B | III / FL | -10–100 | 400V 3~ 50Hz |
| Unichiller 050-H | 62 | G1 1/4 AG male | E1 | III / FL | -20–100 | 400V 3~ 50Hz |
| Unichiller 050w-H | 62 | G1 1/4 AG male | E1 | III / FL | -20–100 | 460V 3~ 60Hz |
| Unichiller 055T | — | G1 1/4 AG male | C3 | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller 055T-H | 74 | G1 1/4 AG male | C3 | III / FL | -20–100 | 400V 3~ 50Hz |
| Unichiller 055Tw | — | G1 1/4 AG male | C3 | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller 060T | — | G1 1/4 AG male | C3 | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller 060T-H | — | G1 1/4 AG male | C3 | III / FL | -20–100 | 400V 3~ 50Hz |
| Unichiller 060Tw-H | — | G1 1/4 AG male | C3 | III / FL | -20–100 | 400V 3~ 50Hz |
| Unichiller 070T-H | 66 | G1 1/4 AG male | C3 | III / FL | -10–100 | 400V 3~ 50Hz |
| Unichiller 070Tw-H | — | G1 1/4 AG male | C3 | III / FL | -10–100 | 400V 3~ 50Hz |
| Unichiller 075w | — | G1 1/4 AG male | E1 | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller 075w-H | — | G1 1/4 AG male | E1 | III / FL | -20–100 | 400V 3~ 50Hz |
| Unichiller 100-H | 58 | G1 1/4 AG male | E1 | III / FL | -20–100 | 460V 3~ 60Hz |
| Unichiller 100T | — | G1 1/4 AG male | C3 | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller 100T-H | — | G1 1/4 AG male | C3 | III / FL | -20–100 | 400V 3~ 50Hz |
| Unichiller 100Tw | 65 | G1 1/4 AG male | C3 | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller GL 035w | — | G1 1/4 AG male | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz |
| Unichiller GL 050w | — | G1 1/4 AG male | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz |
| Unichiller GL 075 | — | G1 1/4 AG male | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz |
| Unichiller GL 075w | — | G1 1/4 AG male | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz |
| Unichiller GL 100w | — | G1 1/4 AG male | Pressure pump, speed not | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller P050 | 62 | G1 1/4 AG male | E2 | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller P050w | 62 | G1 1/4 AG male | E2 | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller P050w-H | 62 | G1 1/4 AG male | E2 | III / FL | -20–100 | — |
| Unichiller P075 | 61 | G1 1/4 AG male | E2 | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller P075w | — | G1 1/4 AG male | E2 | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller P075w-H | — | G1 1/4 AG male | E2 | III / FL | -20–100 | 400V 3~ 50Hz |
| Unichiller P100 | — | G1 1/4 AG male | E2 | I / NFL | -20–40 | 460V 3~ 60Hz |
| Unichiller P100-H | — | G1 1/4 AG male | E2 | III / FL | -20–100 | 400V 3~ 50Hz |
| Unichiller P100w | 58 | G1 1/4 AG male | E2 | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller P100w-H | 58 | G1 1/4 AG male | E2 | III / FL | -20–100 | 400V 3~ 50Hz |
Full specifications
| Noise level | 70 dB(A) |
| Expansion volume | 4 l |
| Pump connection | G3/4 AG male |
| Pump speed adjustable | no |
| Pump type | B |
| External sensor connection | Pt100 |
| Temperature range | -10...40 °C |
| Weight | 134 kg |
| Power supply | 400V 3~ 50Hz |
| Controller | Pilot ONE |
| Digital interface | Ethernet, USB (Host u. Device), RS232 |
| Ambient temperature limit | 5...40 °C |
| Cooling water connection | G1/2 male |
| Cooling water consumption | 32 л/час (at 15°C, flow -10°C) at 15°C, flow 0°C: 70 l/h · at 15°C, flow 15°C: 132 l/h |
| Cooling water differential pressure | 1 bar |
| Cooling Water Pressure | 6 bar |
| Protection rating | IP20 |
| Safety class | I / NFL |
Description
Construction and series positioning
- Water-cooled refrigeration circuit with copper soldered evaporator in stainless steel, atmospheric open expansion tank (4 l) and digital level indicator.
- Free-standing housing on casters/leveling feet; 134 kg, IP20, indoor use only.
- Within the Unichiller series, the 040Tw is the water-cooled variant of the 040 size: the air-cooled 040T is rated 69 dB(A), while the 030Tw is quieter at 61 dB(A). The 040Tw's 70 dB(A) reflects its larger water-cooled package.
- Pump type B with G3/4 AG male connections; pump speed is not adjustable.
Working range and media behavior
- Temperature range -10 to 40 °C; ambient 5 to 40 °C.
- Cooling water circuit: G1/2 male connections, 1 bar minimum differential pressure, 6 bar maximum pressure. Consumption at 15 °C cooling water: 70 l/h at 0 °C flow, 32 l/h at -10 °C flow, 132 l/h at 15 °C flow.
- Cooling capacity falls and cooling-water flow demand rises as cooling-water temperature increases above the rated 15 °C.
- Cooling water intake temperature must be 5 to 20 °C; insulate pipes below the condensation point.
- Wetted cooling-water materials include copper, stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM; only compatible water may be used.
Control, installation and operation
- Pilot ONE controller with Ethernet, USB host/device and RS232; external Pt100 sensor input.
- Power: 400 V 3~ 50 Hz, 3x10 A fuse; three-phase devices below 63 A are supplied with cable but without plug.
- Voltage tolerance ±5% with simultaneous frequency tolerance ±2%; certain combinations are not allowed.
- Power-failure response configurable as OFF/Standby, ON or Power Failure Auto.
- Process Safety mode releases maximum cooling capacity when the overtemperature trigger is reached instead of switching off all poles.
- Refrigerant R-449A (A1, H280), GWP 1397; check charge against room volume at installation.
- Not explosion-protected: do not install or start up in an ATEX zone.
Integration & Operating Notes
Free-standing models require a wall clearance of 50 to 200 cm on either side so that maintenance and refrigerant-circuit work can be performed. Plan the footprint before routing hoses and cables, and keep the area below the unit clear of electrical lines that could be reached by condensation.
The 040Tw draws from a 400 V 3~ 50 Hz supply protected at 3x10 A. Because three-phase devices below 63 A ship with a cable but without a plug, the installer must procure and fit a suitable plug. Verify voltage within ±5% and frequency within ±2% simultaneously before commissioning.
The water-cooled circuit needs a cooling-water supply between 5 °C and 20 °C intake temperature, at least 1 bar differential pressure and no more than 6 bar static pressure. Warmer water reduces cooling capacity and raises the required flow rate, so size the supply for the worst-case condition at your site.
The Pilot ONE allows the power-failure response to be set to OFF/Standby, ON or Power Failure Auto. Choose the setting that matches your process: automatic restart may be unsafe for exothermic reactions, while manual restart may interrupt long unattended runs. Document the chosen mode in the control narrative.
In Process Safety mode the controller releases maximum cooling capacity when the overtemperature protection trigger value is reached, instead of switching off all poles. This is intended for exothermic processes where cutting cooling would cause runaway temperatures; confirm the OT setpoint and sensor placement before enabling it.
The cooling water supply must be shut off during any downtime, including overnight, to prevent water damage and corrosion. Add this step to the shift handover procedure. Refrigerant-circuit work is restricted to approved refrigeration/air-conditioning contractors.
The atmospheric open expansion tank (4 l) is fitted with a digital level indicator. Level monitoring is part of routine checks; a falling level indicates a leak or evaporation and must be investigated before the pump runs dry. Only use thermal fluid compatible with the wetted materials.
The unit is rated IP20 and may only be operated indoors at 5 to 40 °C ambient with illuminance of at least 300 lx and up to 2000 m altitude. It is not explosion-protected and must not be installed or started up inside an ATEX zone. Check the R-449A charge against room volume to stay within the refrigerant limit per m³.
Selection & Integration Q&A
Choose the 040Tw when a cooling-water supply is available and the 040 size is needed; it is water-cooled and rated 70 dB(A). The air-cooled 040T avoids the water connection but is rated 69 dB(A). The 030Tw is smaller and quieter at 61 dB(A) but has less capacity.
Provide cooling water at 5–20 °C intake, 1 bar minimum differential pressure and 6 bar maximum, connected via G1/2 male fittings. Consumption at 15 °C water is 70 l/h at 0 °C flow, 32 l/h at -10 °C and 132 l/h at 15 °C. Insulate pipes below the condensation point.
Install indoors at 5–40 °C ambient, IP20, at least 300 lx illuminance and up to 2000 m altitude, with 50–200 cm wall clearance per side. It is not ATEX-rated. Activate leveling feet and parking brakes before start-up, and shut off cooling water for any downtime.
Three-phase devices below 63 A ship with a cable but without a plug, so a site-fitted plug is required. Routine maintenance includes checking the digital level indicator on the 4 l expansion tank and shutting off cooling water during downtime; refrigerant work must be done by approved contractors.