Peter Huber Kältemaschinenbau Unichiller 055Tw
Peter Huber Kältemaschinenbau Unichiller 055Tw — Recirculating chillers.
The Unichiller 055Tw is a water-cooled recirculating chiller with a C3 pump and Pilot ONE controller, covering -20 to 40 °C. It is the 055-size 'Tw' variant in the series, distinguished by water cooling and a G1/2 cooling-water connection. It serves externally closed process loops requiring heat removal at up to 6 bar cooling-water pressure.
Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection
| Model | Noise level, dB | Pump connection | Pump type | Safety class | Temperature range, °C | Power supply |
|---|---|---|---|---|---|---|
| Unichiller 055Tw Current | — | G1 1/4 AG male | C3 | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller 030T | 69 | G3/4 AG male | B | I / NFL | -10–40 | 460V 3~ 60Hz |
| Unichiller 030Tw | 61 | G3/4 AG male | B | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller 040T | 69 | G3/4 AG male | B | I / NFL | -10–40 | 400V 3~ 50Hz |
| Unichiller 040T-H | 69 | G3/4 AG male | B | III / FL | -10–100 | 400V 3~ 50Hz |
| Unichiller 040Tw | 70 | G3/4 AG male | B | I / NFL | -10–40 | 400V 3~ 50Hz |
| Unichiller 040Tw-H | 70 | G3/4 AG male | B | III / FL | -10–100 | 400V 3~ 50Hz |
| Unichiller 050-H | 62 | G1 1/4 AG male | E1 | III / FL | -20–100 | 400V 3~ 50Hz |
| Unichiller 050w-H | 62 | G1 1/4 AG male | E1 | III / FL | -20–100 | 460V 3~ 60Hz |
| Unichiller 055T | — | G1 1/4 AG male | C3 | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller 055T-H | 74 | G1 1/4 AG male | C3 | III / FL | -20–100 | 400V 3~ 50Hz |
| Unichiller 060T | — | G1 1/4 AG male | C3 | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller 060T-H | — | G1 1/4 AG male | C3 | III / FL | -20–100 | 400V 3~ 50Hz |
| Unichiller 060Tw-H | — | G1 1/4 AG male | C3 | III / FL | -20–100 | 400V 3~ 50Hz |
| Unichiller 070T-H | 66 | G1 1/4 AG male | C3 | III / FL | -10–100 | 400V 3~ 50Hz |
| Unichiller 070Tw-H | — | G1 1/4 AG male | C3 | III / FL | -10–100 | 400V 3~ 50Hz |
| Unichiller 075w | — | G1 1/4 AG male | E1 | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller 075w-H | — | G1 1/4 AG male | E1 | III / FL | -20–100 | 400V 3~ 50Hz |
| Unichiller 100-H | 58 | G1 1/4 AG male | E1 | III / FL | -20–100 | 460V 3~ 60Hz |
| Unichiller 100T | — | G1 1/4 AG male | C3 | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller 100T-H | — | G1 1/4 AG male | C3 | III / FL | -20–100 | 400V 3~ 50Hz |
| Unichiller 100Tw | 65 | G1 1/4 AG male | C3 | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller GL 035w | — | G1 1/4 AG male | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz |
| Unichiller GL 050w | — | G1 1/4 AG male | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz |
| Unichiller GL 075 | — | G1 1/4 AG male | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz |
| Unichiller GL 075w | — | G1 1/4 AG male | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz |
| Unichiller GL 100w | — | G1 1/4 AG male | Pressure pump, speed not | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller P050 | 62 | G1 1/4 AG male | E2 | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller P050w | 62 | G1 1/4 AG male | E2 | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller P050w-H | 62 | G1 1/4 AG male | E2 | III / FL | -20–100 | — |
| Unichiller P075 | 61 | G1 1/4 AG male | E2 | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller P075w | — | G1 1/4 AG male | E2 | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller P075w-H | — | G1 1/4 AG male | E2 | III / FL | -20–100 | 400V 3~ 50Hz |
| Unichiller P100 | — | G1 1/4 AG male | E2 | I / NFL | -20–40 | 460V 3~ 60Hz |
| Unichiller P100-H | — | G1 1/4 AG male | E2 | III / FL | -20–100 | 400V 3~ 50Hz |
| Unichiller P100w | 58 | G1 1/4 AG male | E2 | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller P100w-H | 58 | G1 1/4 AG male | E2 | III / FL | -20–100 | 400V 3~ 50Hz |
Full specifications
| Pump connection | G1 1/4 AG male |
| Pump speed adjustable | no |
| Pump type | C3 |
| External sensor connection | Pt100 |
| Temperature range | -20...40 °C |
| Weight | 250 kg |
| Power supply | 400V 3~ 50Hz |
| Controller | Pilot ONE |
| Digital interface | Ethernet, USB (Host u. Device), RS232 |
| Ambient temperature limit | 5...40 °C |
| Cooling water connection | G1/2 male |
| Cooling water consumption | 180 л/час (at 15°C, flow -10°C) at 15°C, flow 0°C: 260 l/h · at 15°C, flow 15°C: 330 l/h |
| Cooling Water Pressure | 6 bar |
| Protection rating | IP20 |
| Safety class | I / NFL |
Description
Construction and series positioning
The Unichiller 055Tw is a free-standing, water-cooled recirculating chiller. Within the series, the 'T' denotes the base air-cooled family, while the 'Tw' suffix indicates water cooling; the 055 code is a size/volume identifier, not a rating. Sibling models such as the 030T and 040T are air-cooled and smaller, with noise levels of 69 dB(A) for the 030T and 040T and 61 dB(A) for the 030Tw. The 055Tw is the largest sibling listed and is water-cooled, so its acoustic profile is not directly comparable to the air-cooled units. The unit is intended only for externally closed applications and is not explosion-protected; it must not be installed in an ATEX zone.
Working range and media behavior
The temperature range is -20 to 40 °C, with an ambient limit of 5 to 40 °C. Cooling water consumption depends on the leaving fluid temperature: 330 l/h at 15 °C flow, 260 l/h at 0 °C flow, and 180 l/h at -10 °C flow, all at a 15 °C cooling-water inlet. The datasheet states cooling power is valid only at 20 °C room temperature, 15 °C cooling-water inlet, and 0.6 bar differential pressure; higher cooling-water temperatures reduce capacity and may increase flow. The cooling-water circuit contains copper, stainless steel 1.4401, MS, PA, PPE, PTFE, and EPDM, so only compatible water may be used. The refrigerant is R-290 (A3, H220), requiring flammable-refrigerant safety measures and a check of charge versus room volume.
Installation, control and operation
The unit requires a 400 V 3~ 50 Hz supply with a 3x16 A fuse and maximum current of 7.5 A; three-phase devices under 63 A are delivered with cable but without a plug. Cooling water must be supplied at 5 to 20 °C inlet and 0.6 to 6 bar. The Pilot ONE controller provides Ethernet, USB (host and device), and RS232 interfaces, and supports configurable power-failure response (OFF/Standby, ON, or Power Failure Auto). Process Safety mode releases maximum cooling capacity when the overtemperature trigger is reached, rather than switching off all poles. Leveling feet or parking brakes must be engaged before startup, and cooling water must be shut off even for overnight downtimes.
Integration & Operating Notes
Free-standing models require a wall clearance of 50 to 200 cm on either side to allow maintenance access to the refrigerant circuit and connections. Plan the footprint around the 640 x 660 x 1606 mm dimensions and 250 kg net weight, and ensure the floor can support the unit.
The unit draws a maximum of 7.5 A per phase at 400 V 3~ 50 Hz and is delivered with a cable but without a plug because its current is below 63 A. The installer must fit a compatible plug and ensure voltage tolerance stays within ±5% with frequency within ±2%, avoiding the prohibited combination of -5% voltage and +2% frequency.
The chiller is water-cooled and requires a cooling-water differential pressure of at least 0.6 bar and a maximum pressure of 6 bar. Inlet temperature must stay between 5 °C and 20 °C; below the condensation point, internal cooling-water pipes must be insulated to prevent condensation. Shut off cooling water even for short downtimes such as overnight.
Any work on the refrigerant circuit must be performed only by approved refrigeration/air-conditioning system contractors. The unit uses R-290 (A3, H220) refrigerant, so flammable-refrigerant handling rules apply. Verify refrigerant charge against room volume at installation to avoid exceeding the limit per m³ of ambient air.
The unit is rated IP20 and may only be used indoors up to 2000 m altitude, with ambient temperature between 5 °C and 40 °C. Illuminance at the installation site must be at least 300 lx. Electrical lines directly below a water-cooled unit must be protected against liquid ingress from condensation.
Selection & Integration Q&A
Choose the 055Tw when you need water cooling and the larger 055 frame; the 030T and 040T are air-cooled and smaller. The 055Tw requires a cooling-water supply at 5–20 °C and 0.6–6 bar, so it suits sites with available cooling water rather than air-cooled spaces.
Supply cooling water at 5–20 °C inlet, 0.6–6 bar differential pressure, and compatible with copper, stainless steel 1.4401, MS, PA, PPE, PTFE, and EPDM. Consumption is 330 l/h at 15 °C flow, 260 l/h at 0 °C, and 180 l/h at -10 °C, all at 15 °C inlet.
Install indoors only, at 5–40 °C ambient, up to 2000 m altitude, with at least 300 lx illuminance. Maintain 50–200 cm side clearance for maintenance. Engage leveling feet or parking brakes before startup, and shut off cooling water even for overnight downtimes.
The unit ships with a cable but no plug, so a suitable 3x16 A plug must be provided. Refrigerant circuit work requires approved contractors. No consumables or spare parts are listed in the provided facts; follow the manual's maintenance section for service intervals.