Peter Huber Kältemaschinenbau Unichiller 040Tw-H
Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau Unichiller 040Tw-H

Peter Huber Kältemaschinenbau Unichiller 040Tw-H — Recirculating chillers with Noise level 70 dB.

The Unichiller 040Tw-H is a water-cooled recirculating chiller with a 2 kW heater and a temperature range of -10 to 100 °C, distinguished from air-cooled siblings by its G1/2 cooling-water connection and 70 dB(A) sound level. It serves externally closed process loops requiring precise temperature control with Pilot ONE electronics.

Noise level
70 dB

Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection

Model Noise level, dBPump connectionPump typeSafety classTemperature range, °CPower supply
Unichiller 040Tw-H Current 70G3/4 AG maleBIII / FL-10–100400V 3~ 50Hz
Unichiller 030T 69G3/4 AG maleBI / NFL-10–40460V 3~ 60Hz
Unichiller 030Tw 61G3/4 AG maleBI / NFL-20–40400V 3~ 50Hz
Unichiller 040T 69G3/4 AG maleBI / NFL-10–40400V 3~ 50Hz
Unichiller 040T-H 69G3/4 AG maleBIII / FL-10–100400V 3~ 50Hz
Unichiller 040Tw 70G3/4 AG maleBI / NFL-10–40400V 3~ 50Hz
Unichiller 050-H 62G1 1/4 AG maleE1III / FL-20–100400V 3~ 50Hz
Unichiller 050w-H 62G1 1/4 AG maleE1III / FL-20–100460V 3~ 60Hz
Unichiller 055T —G1 1/4 AG maleC3I / NFL-20–40400V 3~ 50Hz
Unichiller 055T-H 74G1 1/4 AG maleC3III / FL-20–100400V 3~ 50Hz
Unichiller 055Tw —G1 1/4 AG maleC3I / NFL-20–40400V 3~ 50Hz
Unichiller 060T —G1 1/4 AG maleC3I / NFL-20–40400V 3~ 50Hz
Unichiller 060T-H —G1 1/4 AG maleC3III / FL-20–100400V 3~ 50Hz
Unichiller 060Tw-H —G1 1/4 AG maleC3III / FL-20–100400V 3~ 50Hz
Unichiller 070T-H 66G1 1/4 AG maleC3III / FL-10–100400V 3~ 50Hz
Unichiller 070Tw-H —G1 1/4 AG maleC3III / FL-10–100400V 3~ 50Hz
Unichiller 075w —G1 1/4 AG maleE1I / NFL-20–40400V 3~ 50Hz
Unichiller 075w-H —G1 1/4 AG maleE1III / FL-20–100400V 3~ 50Hz
Unichiller 100-H 58G1 1/4 AG maleE1III / FL-20–100460V 3~ 60Hz
Unichiller 100T —G1 1/4 AG maleC3I / NFL-20–40400V 3~ 50Hz
Unichiller 100T-H —G1 1/4 AG maleC3III / FL-20–100400V 3~ 50Hz
Unichiller 100Tw 65G1 1/4 AG maleC3I / NFL-20–40400V 3~ 50Hz
Unichiller GL 035w —G1 1/4 AG malePressure pump, speed notI / NFL-20–40460V 3~ 60Hz
Unichiller GL 050w —G1 1/4 AG malePressure pump, speed notI / NFL-20–40460V 3~ 60Hz
Unichiller GL 075 —G1 1/4 AG malePressure pump, speed notI / NFL-20–40460V 3~ 60Hz
Unichiller GL 075w —G1 1/4 AG malePressure pump, speed notI / NFL-20–40460V 3~ 60Hz
Unichiller GL 100w —G1 1/4 AG malePressure pump, speed notI / NFL-20–40400V 3~ 50Hz
Unichiller P050 62G1 1/4 AG maleE2I / NFL-20–40400V 3~ 50Hz
Unichiller P050w 62G1 1/4 AG maleE2I / NFL-20–40400V 3~ 50Hz
Unichiller P050w-H 62G1 1/4 AG maleE2III / FL-20–100—
Unichiller P075 61G1 1/4 AG maleE2I / NFL-20–40400V 3~ 50Hz
Unichiller P075w —G1 1/4 AG maleE2I / NFL-20–40400V 3~ 50Hz
Unichiller P075w-H —G1 1/4 AG maleE2III / FL-20–100400V 3~ 50Hz
Unichiller P100 —G1 1/4 AG maleE2I / NFL-20–40460V 3~ 60Hz
Unichiller P100-H —G1 1/4 AG maleE2III / FL-20–100400V 3~ 50Hz
Unichiller P100w 58G1 1/4 AG maleE2I / NFL-20–40400V 3~ 50Hz
Unichiller P100w-H 58G1 1/4 AG maleE2III / FL-20–100400V 3~ 50Hz

Full specifications

Core Performance & Functional Specifications
Noise level 70 dB(A)
Expansion volume 4 l
Heating capacity 2 kW
Pump connection G3/4 AG male
Pump speed adjustable no
Pump type B
External sensor connection Pt100
Temperature range -10...100 °C
Dimensions, Weight & Mechanical Design
Weight 141 kg
Electrical, Power & Drive Specifications
Current consumption 9 A (max)
Power supply 400V 3~ 50Hz
Interfaces, Connections & Control
Controller Pilot ONE
Digital interface Ethernet, USB (Host u. Device), RS232
Materials, Media & Process Compatibility
Refrigerant R-449A (A1, H280)
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C
Cooling water connection G1/2 male
Cooling water consumption 32 l/h (cooling water 15°C, flow -10°C)
cooling water 15°C, flow 0°C: 70 l/h · cooling water 15°C, flow 15°C: 132 l/h
Cooling water differential pressure 1 bar (min)
Cooling Water Pressure 6 bar (max)
Protection rating IP20
Standards, Safety & General Data
Safety class III / FL

Description

Construction and Series Positioning

The 040Tw-H is a water-cooled variant within the Unichiller series, using R-449A refrigerant and a fixed-speed pump (type B) with G3/4 male process connections. Unlike the air-cooled 030T and 040T siblings (69 dB(A)), this model requires an external cooling-water supply (G1/2 male) and operates at 70 dB(A). The 'w' denotes water cooling; the 'H' indicates an integrated 2 kW heater, enabling active heating as well as cooling.

Hydraulic and Thermal Behavior

The unit is designed for externally closed applications only. The cooling water circuit consumes 32–132 l/h depending on the flow temperature (at 15 °C cooling water), with a minimum differential pressure of 1 bar and maximum pressure of 6 bar. Cooling power decreases as cooling water temperature rises, and flow demand may increase. The internal expansion volume is 4 l, with a minimum filling capacity of 2.5 l. The temperature range spans -10 to 100 °C, and the Pilot ONE controller manages both cooling and heating.

Installation and Control

Installation requires 50–200 cm wall clearance per side for maintenance, indoor use only (illuminance ≥300 lx, altitude ≤2000 m), and protection from ATEX zones. Electrical supply is 400 V 3~ 50 Hz with max 9 A and 3x10 A fusing; a cable is provided but no plug. The Pilot ONE offers Ethernet, USB, and RS232 interfaces, plus a Pt100 external sensor connection. Power-failure response is configurable (OFF/Standby, ON, or Power Failure Auto). Process Safety mode releases maximum cooling if the overtemperature trigger is reached.

Integration & Operating Notes

Mounting
Maintain 50–200 cm side clearance for service access

Free-standing models require a wall clearance of 50 to 200 cm on either side to allow maintenance access to the refrigerant circuit and components. Insufficient clearance can prevent servicing and may lead to overheating or restricted airflow.

Unichiller Operation Manual, Section on Installation
Process Limits
Cooling water intake must stay between 5 °C and 20 °C

Operating with cooling water below the condensation point requires insulation of the cooling water pipes to prevent condensation. Exceeding 20 °C reduces cooling capacity and may increase flow demand, affecting process stability.

Unichiller 040Tw-H Technical Data, Installation Requirements
Cooling & Media
Cooling water pressure must not exceed 6 bar

The cooling water circuit is rated for a maximum pressure of 6 bar and a minimum differential pressure of 1 bar. Exceeding 6 bar can damage the heat exchanger or connections, while insufficient differential pressure may cause inadequate cooling flow.

Unichiller 040Tw-H Technical Data, Cooling Water Specifications
Maintenance
Refrigerant circuit work only by certified contractors

Any work on the refrigerant circuit must be performed by approved refrigeration/air-conditioning system contractors. The refrigerant R-449A (GWP 1397) requires proper handling and recovery per regulations; unauthorized intervention voids safety compliance.

Unichiller Operation Manual, Maintenance Section
Operation
Configure power-failure response to match process risk

The Pilot ONE allows selecting OFF/Standby, ON, or Power Failure Auto after a power outage. For exothermic processes, Power Failure Auto or ON may be necessary to prevent runaway, while OFF/Standby is safer for unattended restart hazards.

Unichiller Operation Manual, Setup Mode

Selection & Integration Q&A

When should I choose the water-cooled 040Tw-H over the air-cooled 040T or 030Tw-H?

Choose 040Tw-H when a cooling-water supply (1–6 bar, 5–20 °C) is available and lower ambient heat rejection is needed; it adds a 2 kW heater. Air-cooled 040T suits sites without water; 030Tw-H offers lower capacity but similar water cooling.

What are the requirements for the cooling water circuit connected to this chiller?

Provide cooling water at 5–20 °C with differential pressure ≥1 bar and static pressure ≤6 bar. Flow demand is 32–132 l/h at 15 °C water, depending on load. Use materials compatible with copper, stainless steel 1.4401, brass, PA, PPE, PTFE, and EPDM; insulate pipes if below dew point.

What installation environment and duty-cycle limits apply to the 040Tw-H?

Install indoors only, at 5–40 °C ambient, ≤2000 m altitude, illuminance ≥300 lx, and not in ATEX zones. Maintain 50–200 cm side clearance. The unit is IP20, so keep it dry. Shut off cooling water during downtimes. Leveling feet or parking brakes must be engaged before operation.

What maintenance and accessories are required, and what is not included in the base delivery?

The base delivery includes a power cable but no plug; the installer must provide a suitable three-phase plug or hardwire. Refrigerant circuit service requires certified contractors. Regular maintenance includes checking cooling water quality and clearing dust. No external sensor is included; a Pt100 can be connected.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Unichiller Operation Manual
Manual ·2,8 МБ ·82 pp.
View PDF
PDF
Unichiller 040Tw-H Technical Data
Datasheet ·63,8 КБ ·2 pp.
View PDF