Peter Huber Kältemaschinenbau Unichiller 100T-H
Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau Unichiller 100T-H

Peter Huber Kältemaschinenbau Unichiller 100T-H — Recirculating chillers.

The Unichiller 100T-H is an air-cooled, CFC/HCFC-free recirculating chiller with a Pilot ONE controller, rated for -20 to 100 °C and 9 kW cooling at 0 °C. It is the high-capacity, non-condenser ('-H') variant in the Unichiller series, distinguished by its 15 kW peak at 15 °C and 3 kW at -20 °C. It serves externally closed process loops requiring stable temperature control with G1 1/4 male pump connections.

Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection

Model Noise level, dBPump connectionPump typeSafety classTemperature range, °CPower supply
Unichiller 100T-H Current —G1 1/4 AG maleC3III / FL-20–100400V 3~ 50Hz
Unichiller 030T 69G3/4 AG maleBI / NFL-10–40460V 3~ 60Hz
Unichiller 030Tw 61G3/4 AG maleBI / NFL-20–40400V 3~ 50Hz
Unichiller 040T 69G3/4 AG maleBI / NFL-10–40400V 3~ 50Hz
Unichiller 040T-H 69G3/4 AG maleBIII / FL-10–100400V 3~ 50Hz
Unichiller 040Tw 70G3/4 AG maleBI / NFL-10–40400V 3~ 50Hz
Unichiller 040Tw-H 70G3/4 AG maleBIII / FL-10–100400V 3~ 50Hz
Unichiller 050-H 62G1 1/4 AG maleE1III / FL-20–100400V 3~ 50Hz
Unichiller 050w-H 62G1 1/4 AG maleE1III / FL-20–100460V 3~ 60Hz
Unichiller 055T —G1 1/4 AG maleC3I / NFL-20–40400V 3~ 50Hz
Unichiller 055T-H 74G1 1/4 AG maleC3III / FL-20–100400V 3~ 50Hz
Unichiller 055Tw —G1 1/4 AG maleC3I / NFL-20–40400V 3~ 50Hz
Unichiller 060T —G1 1/4 AG maleC3I / NFL-20–40400V 3~ 50Hz
Unichiller 060T-H —G1 1/4 AG maleC3III / FL-20–100400V 3~ 50Hz
Unichiller 060Tw-H —G1 1/4 AG maleC3III / FL-20–100400V 3~ 50Hz
Unichiller 070T-H 66G1 1/4 AG maleC3III / FL-10–100400V 3~ 50Hz
Unichiller 070Tw-H —G1 1/4 AG maleC3III / FL-10–100400V 3~ 50Hz
Unichiller 075w —G1 1/4 AG maleE1I / NFL-20–40400V 3~ 50Hz
Unichiller 075w-H —G1 1/4 AG maleE1III / FL-20–100400V 3~ 50Hz
Unichiller 100-H 58G1 1/4 AG maleE1III / FL-20–100460V 3~ 60Hz
Unichiller 100T —G1 1/4 AG maleC3I / NFL-20–40400V 3~ 50Hz
Unichiller 100Tw 65G1 1/4 AG maleC3I / NFL-20–40400V 3~ 50Hz
Unichiller GL 035w —G1 1/4 AG malePressure pump, speed notI / NFL-20–40460V 3~ 60Hz
Unichiller GL 050w —G1 1/4 AG malePressure pump, speed notI / NFL-20–40460V 3~ 60Hz
Unichiller GL 075 —G1 1/4 AG malePressure pump, speed notI / NFL-20–40460V 3~ 60Hz
Unichiller GL 075w —G1 1/4 AG malePressure pump, speed notI / NFL-20–40460V 3~ 60Hz
Unichiller GL 100w —G1 1/4 AG malePressure pump, speed notI / NFL-20–40400V 3~ 50Hz
Unichiller P050 62G1 1/4 AG maleE2I / NFL-20–40400V 3~ 50Hz
Unichiller P050w 62G1 1/4 AG maleE2I / NFL-20–40400V 3~ 50Hz
Unichiller P050w-H 62G1 1/4 AG maleE2III / FL-20–100—
Unichiller P075 61G1 1/4 AG maleE2I / NFL-20–40400V 3~ 50Hz
Unichiller P075w —G1 1/4 AG maleE2I / NFL-20–40400V 3~ 50Hz
Unichiller P075w-H —G1 1/4 AG maleE2III / FL-20–100400V 3~ 50Hz
Unichiller P100 —G1 1/4 AG maleE2I / NFL-20–40460V 3~ 60Hz
Unichiller P100-H —G1 1/4 AG maleE2III / FL-20–100400V 3~ 50Hz
Unichiller P100w 58G1 1/4 AG maleE2I / NFL-20–40400V 3~ 50Hz
Unichiller P100w-H 58G1 1/4 AG maleE2III / FL-20–100400V 3~ 50Hz

Full specifications

Core Performance & Functional Specifications
Expansion volume 7 l
Heating capacity 2 kW
Pump connection G1 1/4 AG male
Pump speed adjustable no
Pump type C3
External sensor connection Pt100
Temperature range -20...100 °C
Dimensions, Weight & Mechanical Design
Weight 284 kg
Electrical, Power & Drive Specifications
Current consumption 16 A
Power supply 400V 3~ 50Hz
Interfaces, Connections & Control
Controller Pilot ONE
Digital interface Ethernet, USB (Host u. Device), RS232
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C
Cooling capacity 15 kW (at 15 °C)
at 0 °C: 9 kW · at -20 °C: 3 kW
Protection rating IP20
Standards, Safety & General Data
Safety class III / FL

Description

Construction and series positioning

Thermal behavior and capacity

Control, installation and operation

Integration & Operating Notes

Mounting
Maintain 50–200 cm side clearance for maintenance access

Free-standing installation requires a wall clearance of 50 to 200 cm on either side to allow servicing of the refrigeration circuit and condenser. The 284 kg weight and 600x790x1614 mm dimensions also demand verification of floor loading and doorway clearance before siting.

Unichiller Operation Manual, Section Installation (p. 25); Unichiller 100T-H Datasheet
Electrical
Provide 3x25 A fusing and fit a plug on site

The 400 V 3~ 50 Hz supply must be sized for 16 A current consumption with 3x25 A fusing. Three-phase devices under 63 A are delivered with a cable but without a plug, so the customer must procure and fit a suitable plug. Voltage and frequency tolerances are only valid in combination; -5% voltage with +2% frequency is not allowed.

Unichiller 100T-H Datasheet, Technical Data (p. 2
Process Limits
Use only externally closed circuits with compatible pressure drop

The unit is designed exclusively for externally closed applications. The external loop pressure drop must be matched to the pump curve (96 l/min at 0 bar, 24 l/min at 5.0 bar) to avoid starving flow at the duty point. Minimum filling capacity is 8.36 l including the 7 l expansion volume.

Unichiller Operation Manual, Function Description (p. 34); Unichiller 100T-H Datasheet
Maintenance
Refrigerant circuit work requires certified contractors

The refrigerant is R-449A (GHS H280, GWP 1397, CO2 equivalent 5.6 t). Work on the refrigerant circuit must only be performed by approved refrigeration/air-conditioning contractors. The air-cooled condenser requires unobstructed airflow and periodic cleaning to avoid capacity loss and high-pressure trips.

Unichiller Operation Manual, Maintenance (p. 17); Unichiller 100T-H Datasheet

Selection & Integration Q&A

When should I choose the 100T-H over the 030T or 030Tw siblings?

Choose the 100T-H when the duty point requires up to 15 kW at 15 °C or 9 kW at 0 °C in a high-capacity configuration. The 030T/030Tw are lower-capacity, low-noise variants (61–69 dB(A)); select those when acoustic limits dominate and cooling demand is lower.

What adjacent system parts must match the 100T-H hydraulic and electrical interfaces?

External hoses and adapters must match G1 1/4 male pump connections, and the loop pressure drop must align with the pump curve (96 l/min at 0 bar, 24 l/min at 5.0 bar). Electrically, provide a 400 V 3~ 50 Hz supply with 3x25 A fusing and a site-fitted plug; a Pt100 sensor can be connected for external control.

What mounting and environmental limits apply to the 100T-H?

Install indoors only, at 5–40 °C ambient, at least 300 lx illuminance, below 2000 m altitude, and outside ATEX zones. IP20 requires a dry, protected location. Maintain 50–200 cm side clearance for maintenance and activate leveling feet or parking brakes before operation.

What maintenance and consumables are required, and what is not included in base delivery?

The air-cooled condenser needs periodic cleaning; refrigerant circuit work requires certified contractors due to R-449A (GWP 1397). The unit ships with a cable but without a plug, and heat transfer fluid is not included—charge at least 8.36 l. No accessories or cables beyond the power cable are stated in the base delivery.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Unichiller Operation Manual
Manual ·2,8 МБ ·82 pp.
View PDF
PDF
Unichiller 100T-H Datasheet
Datasheet ·77,8 КБ ·2 pp.
View PDF