Peter Huber Kältemaschinenbau Unichiller P075w-H
Peter Huber Kältemaschinenbau Unichiller P075w-H — Recirculating chillers.
The Unichiller P075w-H is a water-cooled recirculating chiller with a 7.5 kW cooling capacity at 20 °C, designed for externally closed applications. Its 'P' designation indicates suitability for high-pressure-drop circuits, and the E2 pump delivers up to 130 l/min at 5.7 bar. It operates from -20 to 100 °C with 2 kW heating, serving as a precise temperature control source for industrial processes.
Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection
| Model | Noise level, dB | Pump connection | Pump type | Safety class | Temperature range, °C | Power supply |
|---|---|---|---|---|---|---|
| Unichiller P075w-H Current | — | G1 1/4 AG male | E2 | III / FL | -20–100 | 400V 3~ 50Hz |
| Unichiller 030T | 69 | G3/4 AG male | B | I / NFL | -10–40 | 460V 3~ 60Hz |
| Unichiller 030Tw | 61 | G3/4 AG male | B | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller 040T | 69 | G3/4 AG male | B | I / NFL | -10–40 | 400V 3~ 50Hz |
| Unichiller 040T-H | 69 | G3/4 AG male | B | III / FL | -10–100 | 400V 3~ 50Hz |
| Unichiller 040Tw | 70 | G3/4 AG male | B | I / NFL | -10–40 | 400V 3~ 50Hz |
| Unichiller 040Tw-H | 70 | G3/4 AG male | B | III / FL | -10–100 | 400V 3~ 50Hz |
| Unichiller 050-H | 62 | G1 1/4 AG male | E1 | III / FL | -20–100 | 400V 3~ 50Hz |
| Unichiller 050w-H | 62 | G1 1/4 AG male | E1 | III / FL | -20–100 | 460V 3~ 60Hz |
| Unichiller 055T | — | G1 1/4 AG male | C3 | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller 055T-H | 74 | G1 1/4 AG male | C3 | III / FL | -20–100 | 400V 3~ 50Hz |
| Unichiller 055Tw | — | G1 1/4 AG male | C3 | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller 060T | — | G1 1/4 AG male | C3 | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller 060T-H | — | G1 1/4 AG male | C3 | III / FL | -20–100 | 400V 3~ 50Hz |
| Unichiller 060Tw-H | — | G1 1/4 AG male | C3 | III / FL | -20–100 | 400V 3~ 50Hz |
| Unichiller 070T-H | 66 | G1 1/4 AG male | C3 | III / FL | -10–100 | 400V 3~ 50Hz |
| Unichiller 070Tw-H | — | G1 1/4 AG male | C3 | III / FL | -10–100 | 400V 3~ 50Hz |
| Unichiller 075w | — | G1 1/4 AG male | E1 | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller 075w-H | — | G1 1/4 AG male | E1 | III / FL | -20–100 | 400V 3~ 50Hz |
| Unichiller 100-H | 58 | G1 1/4 AG male | E1 | III / FL | -20–100 | 460V 3~ 60Hz |
| Unichiller 100T | — | G1 1/4 AG male | C3 | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller 100T-H | — | G1 1/4 AG male | C3 | III / FL | -20–100 | 400V 3~ 50Hz |
| Unichiller 100Tw | 65 | G1 1/4 AG male | C3 | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller GL 035w | — | G1 1/4 AG male | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz |
| Unichiller GL 050w | — | G1 1/4 AG male | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz |
| Unichiller GL 075 | — | G1 1/4 AG male | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz |
| Unichiller GL 075w | — | G1 1/4 AG male | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz |
| Unichiller GL 100w | — | G1 1/4 AG male | Pressure pump, speed not | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller P050 | 62 | G1 1/4 AG male | E2 | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller P050w | 62 | G1 1/4 AG male | E2 | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller P050w-H | 62 | G1 1/4 AG male | E2 | III / FL | -20–100 | — |
| Unichiller P075 | 61 | G1 1/4 AG male | E2 | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller P075w | — | G1 1/4 AG male | E2 | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller P100 | — | G1 1/4 AG male | E2 | I / NFL | -20–40 | 460V 3~ 60Hz |
| Unichiller P100-H | — | G1 1/4 AG male | E2 | III / FL | -20–100 | 400V 3~ 50Hz |
| Unichiller P100w | 58 | G1 1/4 AG male | E2 | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller P100w-H | 58 | G1 1/4 AG male | E2 | III / FL | -20–100 | 400V 3~ 50Hz |
Full specifications
| Expansion volume | 48 l |
| Heating capacity | 2 kW |
| Minimum fill volume | 18 l |
| Pump connection | G1 1/4 AG male |
| Pump speed adjustable | no |
| Pump type | E2 |
| External sensor connection | Pt100 |
| Temperature range | -20...100 °C |
| Weight | 296 kg |
| Current consumption | 14 A |
| Power supply | 400V 3~ 50Hz |
| Controller | Pilot ONE |
| Digital interface | Ethernet, USB (Host u. Device), RS232 |
| Ambient temperature limit | 5...40 °C |
| Cooling water connection | G1/2 male |
| Cooling water consumption | 240 л/час (at 15°C, flow -20°C) at 15°C, flow -10°C: 270 л/час · at 15°C, flow 0°C: 330 l/h |
| Cooling Water Pressure | 6 bar |
| Protection rating | IP20 |
| Safety class | III / FL |
Description
Construction and Series Positioning
The Unichiller P075w-H is a water-cooled recirculating chiller in the Unichiller series, distinguished by its 'P' model code, which the manual identifies as particularly suitable for applications requiring high pressure drops. Unlike air-cooled siblings such as the Unichiller 030T (69 dB(A)) or 030Tw (61 dB(A)), this model uses a cooling water circuit with G1/2 male connections and does not rely on fan cooling, making its noise profile irrelevant. The unit is built for externally closed applications only, with a minimum filling capacity of 18 l and an expansion volume of 48 l. The E2 circulation pump provides a maximum delivery of 130 l/min at up to 5.7 bar, though flow falls to 20 l/min at 5.5 bar, so system pressure drop must be checked against the pump curve. The refrigerant is R-449A (GWP 1397, 0.95 kg charge, 1.3 t CO2 equivalent).
Behavior Under Load and Temperature Range
The chiller covers a working temperature range of -20 to 100 °C, with cooling power rated at 7.5 kW at 20 °C, 5.3 kW at 0 °C, 3.3 kW at -10 °C, and 1.8 kW at -20 °C. This capacity must be matched to the actual process temperature, as available cooling drops significantly at lower temperatures. The 2 kW heating capacity allows for precise temperature control across the range. The unit requires a cooling water supply with a differential pressure of at least 0.5 bar and a maximum pressure of 6 bar; cooling water consumption varies with flow temperature: 330 l/h at 0 °C, 270 l/h at -10 °C, and 240 l/h at -20 °C (all at 15 °C cooling water intake). The cooling water intake temperature must be between 5 °C and 20 °C; if below the condensation point, internal cooling water pipes must be insulated.
Installation, Control and Operation
The Pilot ONE controller provides Ethernet, USB (Host and Device), and RS232 interfaces, and supports external Pt100 sensors. The power-failure response is configurable as OFF/Standby, ON, or Power Failure Auto. Process Safety mode releases maximum cooling capacity when the overtemperature trigger value is reached, rather than switching off all poles. The unit is rated IP20 and must be operated indoors at 5–40 °C ambient and at least 300 lx illuminance, up to 2000 m altitude. A wall clearance of 50–200 cm per side is required for maintenance. Electrical supply is 400 V 3~ 50 Hz with a maximum current of 14 A and a 3x16 A fuse; three-phase devices under 63 A are supplied with cable but without a plug. Voltage tolerance is ±5% only with simultaneous frequency tolerance of ±2%, and -5% voltage with +2% frequency is not allowed. The unit is not explosion-protected and must not be installed in an ATEX zone. Leveling feet must be activated and parking brakes applied before operation. Cooling water supply must be shut off even for short downtimes.
Integration & Operating Notes
The chiller delivers 7.5 kW at 20 °C but only 1.8 kW at -20 °C. The process heat load must be checked against the actual operating temperature, not the nominal rating, to avoid insufficient cooling at the low end of the range.
The cooling water supply must provide a differential pressure of at least 0.5 bar and must not exceed 6 bar. Intake temperature must be between 5 °C and 20 °C; if below the condensation point, internal pipes must be insulated to prevent condensation damage.
A voltage tolerance of ±5% is permitted only with a simultaneous frequency tolerance of ±2%. A -5% voltage combined with +2% frequency is explicitly not allowed. The site power quality must be verified to avoid malfunction or damage.
A wall clearance of 50 to 200 cm per side is required on free-standing models to allow maintenance access. The unit must be installed indoors at an illuminance of at least 300 lx and up to 2000 m altitude.
The Pilot ONE controller allows the power-failure response to be set to OFF/Standby, ON, or Power Failure Auto. For exothermic processes, Process Safety mode releases maximum cooling capacity when the overtemperature trigger is reached, instead of switching off all poles.
Work on the refrigerant circuit must only be performed by approved refrigeration/air-conditioning system contractors. The refrigerant is R-449A with a charge of 0.95 kg (1.3 t CO2 equivalent), and room size must be checked to avoid exceeding the refrigerant limit per m³.
Selection & Integration Q&A
Choose the P075w-H when your process has high pressure drop (the 'P' designation) and you have a cooling water supply available. Air-cooled models like the 030T are limited to lower capacities and rely on fan cooling, which adds noise (69 dB(A) for 030T). The P075w-H offers 7.5 kW cooling at 20 °C and is water-cooled, avoiding fan noise but requiring cooling water connections.
The cooling water supply must provide G1/2 male connection, differential pressure of at least 0.5 bar, maximum pressure 6 bar, and intake temperature between 5 °C and 20 °C. The process circuit must be externally closed with a minimum fill volume of 18 l and accommodate an expansion volume of 48 l. The pump delivers up to 130 l/min at 5.7 bar, so check system pressure drop against the pump curve.
Install indoors only, at 5–40 °C ambient, IP20, at least 300 lx illuminance, up to 2000 m altitude. Maintain 50–200 cm wall clearance per side for maintenance. Do not install in an ATEX zone. Activate leveling feet and parking brakes before operation. Shut off cooling water even for short downtimes. Power-failure response is configurable via Pilot ONE.
Refrigerant circuit work must be done by approved refrigeration contractors. The unit is supplied with cable but without a plug for three-phase connection (14 A, 3x16 A fuse). No external Pt100 sensor is included; it must be ordered separately if needed. Regular maintenance includes checking cooling water quality and inspecting for leaks; no specific interval is given in the provided documents.