Peter Huber Kältemaschinenbau Unichiller P100w-H
Peter Huber Kältemaschinenbau Unichiller P100w-H — Recirculating chillers with Noise level 58 dB.
The Unichiller P100w-H is a water-cooled recirculating chiller with a 2 kW heater, a fixed-speed E2 pump and a 48 l expansion volume, rated for -20 to 100 °C. Its 'P' designation marks it for high-pressure-drop process loops, and its Pilot ONE controller provides Ethernet, USB and RS232 interfaces. It serves closed secondary circuits requiring both cooling and active heating.
Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection
| Model | Noise level, dB | Pump connection | Pump type | Safety class | Temperature range, °C | Power supply |
|---|---|---|---|---|---|---|
| Unichiller P100w-H Current | 58 | G1 1/4 AG male | E2 | III / FL | -20–100 | 400V 3~ 50Hz |
| Unichiller 030T | 69 | G3/4 AG male | B | I / NFL | -10–40 | 460V 3~ 60Hz |
| Unichiller 030Tw | 61 | G3/4 AG male | B | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller 040T | 69 | G3/4 AG male | B | I / NFL | -10–40 | 400V 3~ 50Hz |
| Unichiller 040T-H | 69 | G3/4 AG male | B | III / FL | -10–100 | 400V 3~ 50Hz |
| Unichiller 040Tw | 70 | G3/4 AG male | B | I / NFL | -10–40 | 400V 3~ 50Hz |
| Unichiller 040Tw-H | 70 | G3/4 AG male | B | III / FL | -10–100 | 400V 3~ 50Hz |
| Unichiller 050-H | 62 | G1 1/4 AG male | E1 | III / FL | -20–100 | 400V 3~ 50Hz |
| Unichiller 050w-H | 62 | G1 1/4 AG male | E1 | III / FL | -20–100 | 460V 3~ 60Hz |
| Unichiller 055T | — | G1 1/4 AG male | C3 | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller 055T-H | 74 | G1 1/4 AG male | C3 | III / FL | -20–100 | 400V 3~ 50Hz |
| Unichiller 055Tw | — | G1 1/4 AG male | C3 | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller 060T | — | G1 1/4 AG male | C3 | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller 060T-H | — | G1 1/4 AG male | C3 | III / FL | -20–100 | 400V 3~ 50Hz |
| Unichiller 060Tw-H | — | G1 1/4 AG male | C3 | III / FL | -20–100 | 400V 3~ 50Hz |
| Unichiller 070T-H | 66 | G1 1/4 AG male | C3 | III / FL | -10–100 | 400V 3~ 50Hz |
| Unichiller 070Tw-H | — | G1 1/4 AG male | C3 | III / FL | -10–100 | 400V 3~ 50Hz |
| Unichiller 075w | — | G1 1/4 AG male | E1 | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller 075w-H | — | G1 1/4 AG male | E1 | III / FL | -20–100 | 400V 3~ 50Hz |
| Unichiller 100-H | 58 | G1 1/4 AG male | E1 | III / FL | -20–100 | 460V 3~ 60Hz |
| Unichiller 100T | — | G1 1/4 AG male | C3 | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller 100T-H | — | G1 1/4 AG male | C3 | III / FL | -20–100 | 400V 3~ 50Hz |
| Unichiller 100Tw | 65 | G1 1/4 AG male | C3 | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller GL 035w | — | G1 1/4 AG male | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz |
| Unichiller GL 050w | — | G1 1/4 AG male | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz |
| Unichiller GL 075 | — | G1 1/4 AG male | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz |
| Unichiller GL 075w | — | G1 1/4 AG male | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz |
| Unichiller GL 100w | — | G1 1/4 AG male | Pressure pump, speed not | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller P050 | 62 | G1 1/4 AG male | E2 | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller P050w | 62 | G1 1/4 AG male | E2 | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller P050w-H | 62 | G1 1/4 AG male | E2 | III / FL | -20–100 | — |
| Unichiller P075 | 61 | G1 1/4 AG male | E2 | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller P075w | — | G1 1/4 AG male | E2 | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller P075w-H | — | G1 1/4 AG male | E2 | III / FL | -20–100 | 400V 3~ 50Hz |
| Unichiller P100 | — | G1 1/4 AG male | E2 | I / NFL | -20–40 | 460V 3~ 60Hz |
| Unichiller P100-H | — | G1 1/4 AG male | E2 | III / FL | -20–100 | 400V 3~ 50Hz |
| Unichiller P100w | 58 | G1 1/4 AG male | E2 | I / NFL | -20–40 | 400V 3~ 50Hz |
Full specifications
| Noise level | 58 dB(A) |
| Expansion volume | 48 l |
| Heating capacity | 2 kW |
| Minimum fill volume | 18 l |
| Pump connection | G1 1/4 AG male |
| Pump speed adjustable | no |
| Pump type | E2 |
| External sensor connection | Pt100 |
| Temperature range | -20...100 °C |
| Weight | 321 kg |
| Power supply | 400V 3~ 50Hz |
| Controller | Pilot ONE |
| Digital interface | Ethernet, USB (Host u. Device), RS232 |
| Ambient temperature limit | 5...40 °C |
| Cooling water connection | G1/2 male |
| Cooling water consumption | 240 л/час (at 15°C, flow -20°C) at 15°C, flow -10°C: 270 л/час · at 15°C, flow 0°C: 330 l/h |
| Cooling Water Pressure | 6 bar (max) |
| Protection rating | IP20 |
| Safety class | III / FL |
Description
Construction and series positioning
- Water-cooled refrigeration circuit using R-449A (GWP 1397, 1 kg = 1.4 t CO2e); cooling water connection G1/2 male.
- Pump circuit: E2 pump, G1 1/4 AG male connections, fixed speed (not adjustable), max delivery pressure 5.7 bar.
- Hydraulic volume: 18 l minimum fill, 48 l expansion volume.
- The 'P' in the model name designates suitability for applications with high pressure drop; sibling Unichiller 030T/030Tw/040T models are air-cooled variants with different noise profiles (61–69 dB(A) vs 58 dB(A) here).
Behavior under load and media
- Temperature range -20 to 100 °C with 2 kW heating capacity.
- Cooling water inlet must remain between 5 and 20 °C; cooling power falls and required flow rises as cooling water temperature increases.
- Cooling water consumption at 15 °C: 330 l/h at 0 °C flow, 270 l/h at -10 °C, 240 l/h at -20 °C.
- Cooling water circuit materials: copper, stainless steel 1.4401, MS, PA, PPE, PTFE, EPDM — only compatible water may be used.
- Pump curve: 130 l/min at 5.7 bar down to 20 l/min at 5.5 bar; system pressure drop must be checked against this curve.
Installation, control and operation
- Three-phase 400 V 3~ 50 Hz supply, 3x16 A fuse, up to 15.5 A draw; cable supplied without plug (devices <63 A).
- Voltage tolerance ±5% with simultaneous frequency tolerance ±2%; certain combinations (e.g. -5% voltage with +2% frequency) are not permitted.
- Pilot ONE controller; interfaces Ethernet, USB host/device, RS232; external Pt100 sensor connection.
- Power-failure response configurable as OFF/Standby, ON, or Power Failure Auto.
- Process Safety mode releases maximum cooling capacity when the overtemperature trigger is reached instead of switching off all poles.
- IP20, indoor use only, ambient 5–40 °C, illuminance ≥300 lx, altitude up to 2000 m; not for ATEX zones.
- Weight 321 kg, dimensions 740×1160×1050 mm; wall clearance 50–200 cm per side for maintenance.
Integration & Operating Notes
The 400 V three-phase supply needs a 3x16 A protection device and must tolerate ±5% voltage only with ±2% frequency, with certain combinations prohibited. The unit arrives with a cable but no plug, so a matching plug and connection point must be provided on site before commissioning.
Inlet water below the condensation point requires insulation of the internal cooling water pipes. Warmer water reduces cooling power and may increase the required flow rate, so the circuit must be designed for the actual site water temperature rather than nominal conditions.
The G1/2 male connection requires a minimum differential pressure of 0.5 bar and tolerates a maximum of 6 bar. The circuit contains copper, stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM, so only water compatible with these materials may be used to avoid corrosion and fouling.
The unit is designed for externally closed applications. The 'P' model designation indicates suitability for high pressure drop, but the system pressure drop must still be checked against the pump curve (130 l/min at 5.7 bar falling to 20 l/min at 5.5 bar).
The 321 kg unit must be secured by unscrewing/activating the leveling feet and applying caster parking brakes before operation. A wall clearance of 50 to 200 cm per side is required for maintenance, and electrical lines directly below the unit must be protected against liquid ingress from condensation.
The Pilot ONE can be configured for OFF/Standby, ON, or Power Failure Auto after a power outage. For exothermic processes, Process Safety mode releases maximum cooling capacity when the overtemperature trigger is reached instead of switching off all poles.
Any work on the refrigerant circuit must be carried out by approved refrigeration/air-conditioning system contractors. The R-449A charge (GWP 1397) and room size must be checked at installation to stay within the refrigerant limit per m³ of ambient air.
The cooling water supply must be closed even for short downtimes such as overnight to prevent water damage and corrosion during idle periods.
Selection & Integration Q&A
Choose the P100w-H when a water-cooled unit is acceptable and the process loop has high pressure drop, since the 'P' designation targets such applications. The 030T/040T are air-cooled with 69 dB(A) noise versus 58 dB(A) here, so site water availability and noise limits decide.
A G1/2 male connection delivering 5–20 °C water at 0.5–6 bar differential pressure. Consumption is 330 l/h at 0 °C, 270 l/h at -10 °C and 240 l/h at -20 °C flow temperature. Water must be compatible with copper, 1.4401 stainless steel, MS, PA, PPE, PTFE and EPDM.
Indoor use only, 5–40 °C ambient, IP20, illuminance ≥300 lx, altitude ≤2000 m, and no ATEX zone. Allow 50–200 cm wall clearance per side for maintenance, set leveling feet and parking brakes, and protect electrical lines below the unit from condensation.
The three-phase cable is supplied without a plug, so a site plug is needed. Refrigerant circuit work must be done by approved refrigeration contractors; the R-449A charge and room volume must be checked at installation. Cooling water must be shut off even overnight.