Peter Huber Kältemaschinenbau Unichiller P050
Peter Huber Kältemaschinenbau Unichiller P050 — Recirculating chillers with Noise level 62 dB.
The Unichiller P050 is a three-phase 400 V 50 Hz recirculating chiller with a fixed-speed E2 pump (130 l/min, 5.7 bar) and a -20…40 °C working range, built for externally closed loops only. Its 'P' designation targets high-pressure-drop process circuits, distinguishing it from the T-series siblings. It serves as the central cooling source for closed process loops requiring elevated pump head.
Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection
| Model | Noise level, dB | Pump connection | Pump type | Safety class | Temperature range, °C | Power supply |
|---|---|---|---|---|---|---|
| Unichiller P050 Current | 62 | G1 1/4 AG male | E2 | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller 030T | 69 | G3/4 AG male | B | I / NFL | -10–40 | 460V 3~ 60Hz |
| Unichiller 030Tw | 61 | G3/4 AG male | B | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller 040T | 69 | G3/4 AG male | B | I / NFL | -10–40 | 400V 3~ 50Hz |
| Unichiller 040T-H | 69 | G3/4 AG male | B | III / FL | -10–100 | 400V 3~ 50Hz |
| Unichiller 040Tw | 70 | G3/4 AG male | B | I / NFL | -10–40 | 400V 3~ 50Hz |
| Unichiller 040Tw-H | 70 | G3/4 AG male | B | III / FL | -10–100 | 400V 3~ 50Hz |
| Unichiller 050-H | 62 | G1 1/4 AG male | E1 | III / FL | -20–100 | 400V 3~ 50Hz |
| Unichiller 050w-H | 62 | G1 1/4 AG male | E1 | III / FL | -20–100 | 460V 3~ 60Hz |
| Unichiller 055T | — | G1 1/4 AG male | C3 | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller 055T-H | 74 | G1 1/4 AG male | C3 | III / FL | -20–100 | 400V 3~ 50Hz |
| Unichiller 055Tw | — | G1 1/4 AG male | C3 | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller 060T | — | G1 1/4 AG male | C3 | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller 060T-H | — | G1 1/4 AG male | C3 | III / FL | -20–100 | 400V 3~ 50Hz |
| Unichiller 060Tw-H | — | G1 1/4 AG male | C3 | III / FL | -20–100 | 400V 3~ 50Hz |
| Unichiller 070T-H | 66 | G1 1/4 AG male | C3 | III / FL | -10–100 | 400V 3~ 50Hz |
| Unichiller 070Tw-H | — | G1 1/4 AG male | C3 | III / FL | -10–100 | 400V 3~ 50Hz |
| Unichiller 075w | — | G1 1/4 AG male | E1 | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller 075w-H | — | G1 1/4 AG male | E1 | III / FL | -20–100 | 400V 3~ 50Hz |
| Unichiller 100-H | 58 | G1 1/4 AG male | E1 | III / FL | -20–100 | 460V 3~ 60Hz |
| Unichiller 100T | — | G1 1/4 AG male | C3 | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller 100T-H | — | G1 1/4 AG male | C3 | III / FL | -20–100 | 400V 3~ 50Hz |
| Unichiller 100Tw | 65 | G1 1/4 AG male | C3 | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller GL 035w | — | G1 1/4 AG male | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz |
| Unichiller GL 050w | — | G1 1/4 AG male | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz |
| Unichiller GL 075 | — | G1 1/4 AG male | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz |
| Unichiller GL 075w | — | G1 1/4 AG male | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz |
| Unichiller GL 100w | — | G1 1/4 AG male | Pressure pump, speed not | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller P050w | 62 | G1 1/4 AG male | E2 | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller P050w-H | 62 | G1 1/4 AG male | E2 | III / FL | -20–100 | — |
| Unichiller P075 | 61 | G1 1/4 AG male | E2 | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller P075w | — | G1 1/4 AG male | E2 | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller P075w-H | — | G1 1/4 AG male | E2 | III / FL | -20–100 | 400V 3~ 50Hz |
| Unichiller P100 | — | G1 1/4 AG male | E2 | I / NFL | -20–40 | 460V 3~ 60Hz |
| Unichiller P100-H | — | G1 1/4 AG male | E2 | III / FL | -20–100 | 400V 3~ 50Hz |
| Unichiller P100w | 58 | G1 1/4 AG male | E2 | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller P100w-H | 58 | G1 1/4 AG male | E2 | III / FL | -20–100 | 400V 3~ 50Hz |
Full specifications
| Noise level | 62 dB(A) |
| Expansion volume | 48 l |
| Minimum fill volume | 18 l |
| Pump connection | G1 1/4 AG male |
| Pump speed adjustable | no |
| Pump type | E2 |
| External sensor connection | Pt100 |
| Temperature range | -20...40 °C |
| Weight | 268 kg |
| Current consumption | 8 A (max) |
| Power supply | 400V 3~ 50Hz |
| Controller | Pilot ONE |
| Digital interface | Ethernet, USB (Host u. Device), RS232 |
| Ambient temperature limit | 5...40 °C |
| Protection rating | IP20 |
| Safety class | I / NFL |
Description
Construction and series positioning
- The P050 is the high-pressure-drop variant of the Unichiller series; the manual states that models with 'P' in the model name are particularly suitable for applications requiring high pressure drops.
- Unlike the T-series siblings (030T, 030Tw, 030Tw-H, 040T), which are differentiated mainly by acoustic package (61–69 dB(A)), the P050's defining trait is hydraulic: a fixed-speed E2 pump delivering up to 130 l/min and 5.7 bar.
- The hydraulic circuit is an atmospheric open expansion tank (48 l expansion volume, 18 l minimum fill) with a digital level indicator; the unit is intended only for externally closed applications, so open baths or vented loops are excluded.
- Refrigerant is R-449A (A1, H280), charge 1.03 kg, GWP 1397; pressure equipment is classified Art. 4.3 PED.
Behavior under load and media
- Cooling capacity is rated at 20 °C room temperature and drops as ambient temperature rises; the permissible ambient window is 5…40 °C.
- Pump flow falls sharply above 5.0 bar, so the external circuit's pressure drop must be checked against the 5.7 bar maximum delivery pressure at the required flow.
- Temperature range is -20…40 °C; an external Pt100 sensor connection is provided for process-side control.
- Process Safety mode releases maximum cooling capacity when the overtemperature trigger is reached instead of switching off all poles — relevant for exothermic loads.
Installation, control and operation
- Controller is Pilot ONE with Ethernet, USB (host and device) and RS232 interfaces; power-failure response is configurable as OFF/Standby, ON, or Power Failure Auto.
- Electrical supply is 400 V 3~ 50 Hz, 8 A max, 3×10 A fusing; three-phase devices below 63 A are delivered with cable but without a plug, so the site plug must be provided.
- Voltage and frequency tolerances must be met simultaneously (-5% voltage with +2% frequency is not allowed).
- Enclosure is IP20; installation is indoors only, at ≥300 lx illuminance and up to 2000 m altitude, with 50–200 cm wall clearance per side for maintenance.
- Pump connections are G1 1/4 AG male; maximum tightening torques must be observed and connections counterheld during hose installation.
Integration & Operating Notes
The chiller is designed exclusively for externally closed applications. An open bath or vented loop would expose the atmospheric expansion tank to uncontrolled evaporation and air ingress, invalidating level monitoring and pump protection.
Three-phase devices with current consumption below 63 A are delivered with cable but without a plug, so the customer must provide the mating site plug. The supply must be 400 V 3~ 50 Hz with 8 A max current and 3×10 A fusing; voltage and frequency tolerances must be satisfied simultaneously.
A wall clearance of 50 to 200 cm per side is required for maintenance access. Before switch-on, parking brakes at the casters must be activated and/or leveling feet unscrewed so the unit cannot move during operation. Installation is indoors only, at ≥300 lx and up to 2000 m altitude.
The E2 pump delivers 130 l/min maximum and 5.7 bar maximum pressure, but flow falls sharply above 5.0 bar. The external circuit's pressure drop at the required flow must be checked against this curve; the 'P' designation targets high-pressure-drop applications but does not remove the hydraulic limit.
Output data are valid for a 20 °C room temperature; if ambient temperature rises, cooling capacity may drop. The installation site must keep ambient between 5 °C and 40 °C, and the refrigerant charge (1.03 kg R-449A) must be checked against room volume to avoid exceeding the refrigerant limit per m³.
Work on the coolant circuit must be carried out by approved refrigeration/air-conditioning system contractors. Routine operation includes checking the digital level indicator and the atmospheric open expansion tank to avoid pump cavitation and air ingress.
Electrical lines directly below a water-cooled unit must be protected against liquid ingress from condensation. The enclosure is IP20, so the installation site must be free of wash-down water and dust.
Selection & Integration Q&A
Choose the P050 when the external loop has high pressure drop: its 'P' designation and E2 pump (130 l/min, 5.7 bar) target such circuits. The T-series siblings differ mainly in acoustic package (61–69 dB(A)); select them when pump head is not the constraint.
A 400 V 3~ 50 Hz supply with 8 A max current and 3×10 A fusing, plus the mating three-phase plug (cable delivered without plug below 63 A). Hydraulically, G1 1/4 AG male pump connections; observe maximum tightening torques and counterhold fittings.
Indoors only, ambient 5…40 °C, ≥300 lx illuminance, up to 2000 m altitude, 50–200 cm clearance per side, IP20 enclosure, no ATEX zone. Cooling capacity is rated at 20 °C room temperature and drops as ambient rises.
The base delivery excludes the site three-phase plug. Routine checks cover the digital level indicator and atmospheric expansion tank; refrigerant circuit work must be done by approved refrigeration contractors. No consumables or cables beyond the delivered cable are specified.