Peter Huber Kältemaschinenbau Unistat 525w Dynamisches
Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau Unistat 525w Dynamisches

Peter Huber Kältemaschinenbau Unistat 525w Dynamisches — Temperature control units with Noise level 61 dB.

The Unistat 525w Dynamisches is a water-cooled, free-standing temperature control unit with a magnetically coupled stainless steel pump and Pilot ONE controller, covering -55 to 250 °C. Within the Unistat 5xx Dynamisches series it is the water-cooled variant, distinguished from the air-cooled 525 Dynamisches and the smaller 510w/515w/520w by its cooling and pump capacity. It serves as a dynamic heating/cooling source for externally closed or open tempering circuits in process and laboratory systems.

Noise level
61 dB

Peter Huber Kältemaschinenbau Unistat Series — Model Comparison & Selection

Model Noise level, dBDisplay resolutionHeating capacity, WPump connectionPump typeTemperature range, °C
Unistat 525w Dynamisches Current 610, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat 510w Dynamisches 600, 016000M30x1, 5 AG malemagnetically coupled, st-50–250
Unistat 515w Dynamisches —0, 016000M30x1, 5 AG malemagnetically coupled, st-50–250
Unistat 520w Dynamisches 610, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat 525 Dynamisches 560, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat 527w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat 530w Dynamisches 590, 0112000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat 540w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat 545w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat 610w Dynamisches 620, 016000M30x1, 5 AG malemagnetically coupled, st-60–200
Unistat 615w Dynamisches 620, 0112000M30x1, 5 AG malePressure pump, variable -60–200
Unistat 620w Dynamisches 680, 0112000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat 625w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat 630w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat 635w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat 640w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat 645w Dynamisches —0, 0136000flange DN32 PN10/40 EN10magnetically coupled, st-60–200
Unistat 650w Dynamisches 730, 0148000flange DN32 PN10/40 EN10magnetically coupled, st-60–200
Unistat 680w Dynamisches —0, 0196000DN50 PN16 (DIN EN 1092-1magnetically coupled, st-60–200
Unistat GL 530w Dynamisches 610, 016000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL 535w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL 540w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL 550w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL 560w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL 570w Dynamisches —0, 0148000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P530w Dynamisches 610, 016000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P535w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P540w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P550w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P560w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P570w Dynamisches —0, 0148000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat P510 Dynamisches 600, 016000M30x1, 5 AG malemagnetically coupled, st-50–250
Unistat P510w Dynamisches 600, 016000M30x1, 5 AG malemagnetically coupled, st-50–250
Unistat P515w Dynamisches —0, 016000M30x1, 5 AG malemagnetically coupled, st-50–250
Unistat P520 Dynamisches —0, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat P520w Dynamisches 610, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat P525 Dynamisches 560, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat P525w Dynamisches 610, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat P527w Dynamisches 570, 0112000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat P530w Dynamisches 620.0112000M38x1,5 AG malemagnetically coupled, st-55–250
Unistat P540w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat P545w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat P610 Dynamisches —0, 016000M30x1, 5 AG malemagnetically coupled, st-60–200
Unistat P610w Dynamisches 620, 016000M30x1, 5 AG malemagnetically coupled, st-60–200
Unistat P615 Dynamisches —0, 0112000M30x1, 5 AG malemagnetically coupled, st-60–200
Unistat P615w Dynamisches 620, 0112000M30x1, 5 AG malemagnetically coupled, st-60–200
Unistat P620w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat P625w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat P630w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat P635w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat P645w Dynamisches —0, 0136000flange DN32 PN10/40 EN10magnetically coupled, st-60–200
Unistat P650w Dynamisches —0, 0148000flange DN32 PN10/40 EN10magnetically coupled, st-60–200

Full specifications

Core Performance & Functional Specifications
Noise level 61 dB(A)
Control output POKO ONE
Expansion volume 18 l
Heating capacity 6 kW
Pump connection M30x1, 5 AG male
Pump speed adjustable Yes
Pump type magnetically coupled, stainless steel
External sensor connection Pt100
Temperature range -55...250 °C
Dimensions, Weight & Mechanical Design
Weight 215 kg
Electrical, Power & Drive Specifications
Power supply 400V 3~ 50Hz
Interfaces, Connections & Control
Controller Pilot ONE
Display resolution 0, 01 K
Digital interface Ethernet, USB (Host u. Device), RS232
Materials, Media & Process Compatibility
Maximum viscosity 50 mm²/s
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C
Cooling water connection G1/2 male
Cooling water consumption 430 l/h (at 15°C, flow 0°C)
Cooling water differential pressure 1 bar
Cooling Water Pressure 6 bar
Protection rating IP20
Standards, Safety & General Data
Safety class III / FL

Description

Construction and series positioning

Behavior across the working range

Installation, control and operation

Integration & Operating Notes

Electrical
Provide a 3x16 A three-phase supply and a site plug

The unit draws up to 13.5 A on 400 V 3~ 50 Hz and is delivered with a cable but without a plug, so the electrical contractor must size the feeder and breaker for 3x16 A and fit a suitable plug. Voltage tolerance is ±5% with ±2% frequency, and the combination of -5% voltage with +2% frequency is not permitted.

Unistat 525w Technical Data, page 2; Unistat Operation Manual, Section on power connection
Cooling & Media
Cooling water must stay within 5–20 °C and 1–6 bar

Supply cooling water at 5–20 °C with at least 1 bar differential pressure and no more than 6 bar at the G1/2 male connection. Published cooling capacity assumes 15 °C inlet and 1 bar differential; warmer water lowers available cooling. Insulate the cooling-water pipes if the water can drop below the dew point, and use only water compatible with the copper, 1.4401 stainless steel, MS, PA, PPE, PTFE and EPDM circuit materials.

Unistat 525w Technical Data, page 2
Mounting
Install level, indoors, outside ATEX zones, with a drip tray

The 215 kg unit must stand upright on level ground with leveling feet activated and caster brakes engaged; casters are not for transport and carry only 25% of total mass symmetrically. IP20 requires a dry indoor location, ambient 5–40 °C, and the responsible body must install a condensation-water/heat-transfer-fluid drip tray below the unit. Installation inside an ATEX zone is prohibited.

Unistat Operation Manual, Commissioning; Unistat 525w Technical Data, page 2
Process Limits
Match expansion-vessel lock state to the application type

For externally closed applications the expansion vessel must remain unlocked; locking it causes overpressure damage. For externally open (bath) applications the vessel must be locked to prevent fluid loss. Minimum filling is 5.1 l with an 18 l expansion tank, so the heat-transfer-fluid charge and expansion allowance must be planned for the actual circuit volume.

Unistat Operation Manual, Commissioning and Setup Mode

Selection & Integration Q&A

When should I choose the water-cooled Unistat 525w Dynamisches instead of the air-cooled 525 Dynamisches or the smaller 510w/515w/520w?

Pick the 525w when a cooling-water supply of 5–20 °C at ≥1 bar is available and 61 dB(A) is acceptable; the air-cooled 525 Dynamisches (56 dB(A)) avoids water piping but rejects heat to the room. Choose 510w/515w/520w only if their lower capacity covers the load, since the 525w provides 10 kW cooling with thermooil and 6 kW heating.

What must be provided on the cooling-water and process sides to connect this unit?

Cooling water: G1/2 male, 5–20 °C, 1–6 bar differential, 430 l/h at 15 °C/0 °C flow, with insulated pipes if below dew point. Process: M30x1.5 male pump connection with bore shape Y (60°) per DIN 3863; hoses need a ball socket per DIN 3863 and sleeve nut per DIN 3870. Electrical: 400 V 3~ 50 Hz, 3x16 A, cable supplied without plug.

What mounting and duty-cycle limits apply from the manual?

Install upright and level indoors, ambient 5–40 °C, IP20, outside ATEX zones, with a drip tray; allow ~2 h acclimation after cold/warm moves. Casters are not for transport and carry only 25% of mass. Shut off cooling water overnight. For FL fluids the fire point must be ≥65 °C; ethanol only under supervision.

What maintenance and accessories are needed beyond the base delivery?

The base unit ships with a power cable but no plug, and no process hoses or fittings. Plan periodic hose/connection inspection and replacement, cooling-water strainer cleaning, liquefier-fin cleaning, heat-transfer-fluid inspection/replacement, and refrigerant work by approved contractors. A drip tray and, if required, a gas-detection option must be engineered on site.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Unistat 525w Technical Data
Datasheet ·76,1 КБ ·2 pp.
View PDF
PDF
Unistat® Operation Manual — Unistat® 5, Unistat® Pilot ONE®
Manual ·3,6 МБ ·100 pp.
View PDF
PDF
Unistat Operation Manual
Manual ·3,7 МБ ·102 pp.
View PDF