Peter Huber Kältemaschinenbau Unistat 640w Dynamisches
Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau Unistat 640w Dynamisches

Peter Huber Kältemaschinenbau Unistat 640w Dynamisches — Temperature control units.

The Unistat 640w Dynamisches is a water-cooled, free-standing temperature control unit with a magnetically coupled stainless-steel pump and Pilot ONE controller, covering -60 to 200 °C with 24 kW heating. It is the 6xx-series dynamic modification, distinguished from smaller 5xx siblings by its higher heating capacity and 196 l/min pump delivery. It serves closed-loop process temperature control where rapid, high-flow heat transfer is required.

Peter Huber Kältemaschinenbau Unistat Series — Model Comparison & Selection

Model Noise level, dBDisplay resolutionHeating capacity, WPump connectionPump typeTemperature range, °C
Unistat 640w Dynamisches Current —0, 0124000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat 510w Dynamisches 600, 016000M30x1, 5 AG malemagnetically coupled, st-50–250
Unistat 515w Dynamisches —0, 016000M30x1, 5 AG malemagnetically coupled, st-50–250
Unistat 520w Dynamisches 610, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat 525 Dynamisches 560, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat 525w Dynamisches 610, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat 527w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat 530w Dynamisches 590, 0112000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat 540w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat 545w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat 610w Dynamisches 620, 016000M30x1, 5 AG malemagnetically coupled, st-60–200
Unistat 615w Dynamisches 620, 0112000M30x1, 5 AG malePressure pump, variable -60–200
Unistat 620w Dynamisches 680, 0112000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat 625w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat 630w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat 635w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat 645w Dynamisches —0, 0136000flange DN32 PN10/40 EN10magnetically coupled, st-60–200
Unistat 650w Dynamisches 730, 0148000flange DN32 PN10/40 EN10magnetically coupled, st-60–200
Unistat 680w Dynamisches —0, 0196000DN50 PN16 (DIN EN 1092-1magnetically coupled, st-60–200
Unistat GL 530w Dynamisches 610, 016000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL 535w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL 540w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL 550w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL 560w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL 570w Dynamisches —0, 0148000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P530w Dynamisches 610, 016000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P535w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P540w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P550w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P560w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P570w Dynamisches —0, 0148000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat P510 Dynamisches 600, 016000M30x1, 5 AG malemagnetically coupled, st-50–250
Unistat P510w Dynamisches 600, 016000M30x1, 5 AG malemagnetically coupled, st-50–250
Unistat P515w Dynamisches —0, 016000M30x1, 5 AG malemagnetically coupled, st-50–250
Unistat P520 Dynamisches —0, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat P520w Dynamisches 610, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat P525 Dynamisches 560, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat P525w Dynamisches 610, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat P527w Dynamisches 570, 0112000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat P530w Dynamisches 620.0112000M38x1,5 AG malemagnetically coupled, st-55–250
Unistat P540w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat P545w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat P610 Dynamisches —0, 016000M30x1, 5 AG malemagnetically coupled, st-60–200
Unistat P610w Dynamisches 620, 016000M30x1, 5 AG malemagnetically coupled, st-60–200
Unistat P615 Dynamisches —0, 0112000M30x1, 5 AG malemagnetically coupled, st-60–200
Unistat P615w Dynamisches 620, 0112000M30x1, 5 AG malemagnetically coupled, st-60–200
Unistat P620w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat P625w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat P630w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat P635w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat P645w Dynamisches —0, 0136000flange DN32 PN10/40 EN10magnetically coupled, st-60–200
Unistat P650w Dynamisches —0, 0148000flange DN32 PN10/40 EN10magnetically coupled, st-60–200

Full specifications

Core Performance & Functional Specifications
Control output POKO ONE
Heating capacity 24 kW
Pump connection M38x1, 5 AG male
Pump speed adjustable Yes
Pump type magnetically coupled, stainless steel
External sensor connection Pt100
Temperature range -60...200 °C
Dimensions, Weight & Mechanical Design
Weight 728 kg
Electrical, Power & Drive Specifications
Current consumption 48 A (max)
Power supply 400V 3~ 50Hz
Interfaces, Connections & Control
Controller Pilot ONE
Display resolution 0, 01 K
Digital interface Ethernet, USB (Host u. Device), RS232
Materials, Media & Process Compatibility
Maximum viscosity 100 mm²/s
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C
Cooling water connection G3/4 male
Cooling water differential pressure 1 bar (min)
Cooling Water Pressure 6 bar (max)
Protection rating IP20
Standards, Safety & General Data
Safety class III / FL

Description

Construction and series positioning

The Unistat 640w is a water-cooled (w suffix) free-standing unit in the 6xx size class, weighing 728 kg with overall dimensions 918×963×1772 mm. Its pump is magnetically coupled and stainless steel, with M38×1.5 male process connections and adjustable speed. Compared with the 5xx siblings (510w, 515w, 520w, 525), the 640w carries a larger 24 kW heating capacity and a 196 l/min maximum pump delivery; the 5xx models are air-cooled or water-cooled alternatives at lower capacity. The unit uses refrigerant R-452A (5.5 kg, GWP 2141, 11.8 t CO2e) and is CFC/HCFC-free.

Working range and behavior

Control, installation and operation

The Pilot ONE controller with POKO ONE control output provides Ethernet, USB (host and device) and RS232 interfaces, plus a Pt100 external sensor connection. The unit is IP20 and must be installed in ambient temperature 5–40 °C, outside ATEX zones. Electrical supply is 400 V 3~ 50 Hz, max current 48 A, fusing 3×50 A; three-phase devices below 63 A are delivered with cable but without a plug. Leakage current exceeds 3.5 mA, so protective earthing and RCD selection must account for this. Voltage tolerance is ±5% with simultaneous frequency tolerance ±2%, and the combination of -5% voltage with +2% frequency is not allowed. The unit must be transported and stored upright only, and an emptied unit may be moved; casters are not for transport and carry only 25% of total mass symmetrically. Leveling feet must be activated and parking brakes engaged before commissioning. For externally closed applications the expansion vessel must remain unlocked; for externally open applications it must be locked. Allow about 2 hours acclimation when moving between cold and warm environments before power-on. The cooling water supply should be shut off even for short downtimes such as overnight.

Integration & Operating Notes

Cooling & Media
Cooling water must be 5–20 °C at 1–4 bar differential, max 6 bar

The cooling water circuit requires G3/4 male connections and a supply between 5 °C and 20 °C inlet temperature, with differential pressure of 1–4 bar and maximum pressure 6 bar. Lower inlet temperatures require insulating the cooling water pipes to prevent condensation. Rated cooling power is valid only at 20 °C room temperature, 15 °C cooling water inlet and 1 bar differential pressure; higher cooling water temperature reduces cooling power. Shut off the cooling water supply even for short downtimes such as overnight.

Unistat 640w Technical Data, page 2; Unistat Operation Manual, page 29
Control & I/O
Process Safety mode requires compressor set to Permanently ON

In Process Safety mode, when the set overtemperature trigger value is reached the controller releases maximum cooling capacity instead of switching off all poles. This mode requires the compressor to be set to Permanently ON. Power Failure Auto resumes temperature control automatically after a power outage if it was active; choose the power-interruption behavior according to whether unattended restart is acceptable for the process.

Unistat Operation Manual, page 19–20
Maintenance
Periodically check hoses and connections for leaks and quality

Hoses and connections must be periodically checked for leaks and quality and replaced as needed. Work on the coolant circuit must be carried out by approved refrigeration/air-conditioning system contractors. The responsible body must install a condensation water / heat transfer fluid drip tray below the unit; national legislation may prescribe it. The unit must not be installed or started within an ATEX zone; explosion protection requires an Ex px cabinet.

Unistat Operation Manual, page 29; Unistat Operation Manual, page 15–17

Selection & Integration Q&A

When should I choose the Unistat 640w Dynamisches over the smaller 5xx siblings in the series?

Choose the 640w when you need 24 kW heating and up to 196 l/min pump delivery for large or high-flow closed loops. The 5xx models (510w, 515w, 520w, 525) are smaller-capacity alternatives; select them when 24 kW heating and 196 l/min are not required and a more compact unit is acceptable.

What are the electrical supply and protection requirements before installing this unit?

Provide a 400 V 3~ 50 Hz supply with 3×50 A fusing and a suitable mating plug (cable delivered without plug). Account for leakage current >3.5 mA in RCD selection and earthing. Voltage tolerance ±5% with frequency ±2%, but -5% voltage with +2% frequency is not allowed.

What cooling water supply and ambient conditions does the unit require at the installation site?

Cooling water: G3/4 male connections, inlet 5–20 °C, differential pressure 1–4 bar, max 6 bar; insulate pipes if inlet below ambient to prevent condensation. Ambient: 5–40 °C, IP20, outside ATEX zones. Rated cooling power assumes 20 °C room, 15 °C water inlet, 1 bar differential.

What maintenance and accessories are required that are not included in the base delivery?

Base delivery excludes the three-phase mating plug. Plan for a drip tray (may be required by local regulations), periodic hose/connection inspection and replacement, and cooling water shut-off for short downtimes. Refrigerant-circuit work requires approved contractors. Heat transfer fluid must be selected for the -60 to 200 °C range and FL fire-point ≥65 °C if flammable.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Unistat 640w Technical Data
Datasheet ·18,8 КБ ·2 pp.