Peter Huber Kältemaschinenbau Unistat 640w Dynamisches
Peter Huber Kältemaschinenbau Unistat 640w Dynamisches — Temperature control units.
The Unistat 640w Dynamisches is a water-cooled, free-standing temperature control unit with a magnetically coupled stainless-steel pump and Pilot ONE controller, covering -60 to 200 °C with 24 kW heating. It is the 6xx-series dynamic modification, distinguished from smaller 5xx siblings by its higher heating capacity and 196 l/min pump delivery. It serves closed-loop process temperature control where rapid, high-flow heat transfer is required.
Peter Huber Kältemaschinenbau Unistat Series — Model Comparison & Selection
| Model | Noise level, dB | Display resolution | Heating capacity, W | Pump connection | Pump type | Temperature range, °C |
|---|---|---|---|---|---|---|
| Unistat 640w Dynamisches Current | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 510w Dynamisches | 60 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat 515w Dynamisches | — | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat 520w Dynamisches | 61 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 525 Dynamisches | 56 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 525w Dynamisches | 61 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 527w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 530w Dynamisches | 59 | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 540w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 545w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 610w Dynamisches | 62 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 615w Dynamisches | 62 | 0, 01 | 12000 | M30x1, 5 AG male | Pressure pump, variable | -60–200 |
| Unistat 620w Dynamisches | 68 | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 625w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 630w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 635w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 645w Dynamisches | — | 0, 01 | 36000 | flange DN32 PN10/40 EN10 | magnetically coupled, st | -60–200 |
| Unistat 650w Dynamisches | 73 | 0, 01 | 48000 | flange DN32 PN10/40 EN10 | magnetically coupled, st | -60–200 |
| Unistat 680w Dynamisches | — | 0, 01 | 96000 | DN50 PN16 (DIN EN 1092-1 | magnetically coupled, st | -60–200 |
| Unistat GL 530w Dynamisches | 61 | 0, 01 | 6000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 535w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 540w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 550w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 560w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 570w Dynamisches | — | 0, 01 | 48000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P530w Dynamisches | 61 | 0, 01 | 6000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P535w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P540w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P550w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P560w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P570w Dynamisches | — | 0, 01 | 48000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat P510 Dynamisches | 60 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat P510w Dynamisches | 60 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat P515w Dynamisches | — | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat P520 Dynamisches | — | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P520w Dynamisches | 61 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P525 Dynamisches | 56 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P525w Dynamisches | 61 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P527w Dynamisches | 57 | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P530w Dynamisches | 62 | 0.01 | 12000 | M38x1,5 AG male | magnetically coupled, st | -55–250 |
| Unistat P540w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P545w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P610 Dynamisches | — | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P610w Dynamisches | 62 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P615 Dynamisches | — | 0, 01 | 12000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P615w Dynamisches | 62 | 0, 01 | 12000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P620w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P625w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P630w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P635w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P645w Dynamisches | — | 0, 01 | 36000 | flange DN32 PN10/40 EN10 | magnetically coupled, st | -60–200 |
| Unistat P650w Dynamisches | — | 0, 01 | 48000 | flange DN32 PN10/40 EN10 | magnetically coupled, st | -60–200 |
Full specifications
| Control output | POKO ONE |
| Heating capacity | 24 kW |
| Pump connection | M38x1, 5 AG male |
| Pump speed adjustable | Yes |
| Pump type | magnetically coupled, stainless steel |
| External sensor connection | Pt100 |
| Temperature range | -60...200 °C |
| Weight | 728 kg |
| Current consumption | 48 A (max) |
| Power supply | 400V 3~ 50Hz |
| Controller | Pilot ONE |
| Display resolution | 0, 01 K |
| Digital interface | Ethernet, USB (Host u. Device), RS232 |
| Maximum viscosity | 100 mm²/s |
| Ambient temperature limit | 5...40 °C |
| Cooling water connection | G3/4 male |
| Cooling water differential pressure | 1 bar (min) |
| Cooling Water Pressure | 6 bar (max) |
| Protection rating | IP20 |
| Safety class | III / FL |
Description
Construction and series positioning
The Unistat 640w is a water-cooled (w suffix) free-standing unit in the 6xx size class, weighing 728 kg with overall dimensions 918×963×1772 mm. Its pump is magnetically coupled and stainless steel, with M38×1.5 male process connections and adjustable speed. Compared with the 5xx siblings (510w, 515w, 520w, 525), the 640w carries a larger 24 kW heating capacity and a 196 l/min maximum pump delivery; the 5xx models are air-cooled or water-cooled alternatives at lower capacity. The unit uses refrigerant R-452A (5.5 kg, GWP 2141, 11.8 t CO2e) and is CFC/HCFC-free.
Working range and behavior
- Temperature range: -60 to 200 °C; display resolution 0.01 K.
- Heating capacity: 24 kW.
- Pump: max delivery 196 l/min, max delivery pressure 2.5 bar, 175 l/min at 0.5 bar; external circuit pressure drop must be checked against this curve.
- Cooling water: G3/4 male connections; inlet temperature 5–20 °C; differential pressure 1–4 bar; maximum pressure 6 bar. Rated cooling output is valid only at 20 °C room temperature, 15 °C cooling water inlet and 1 bar differential pressure; higher cooling water temperature reduces cooling power.
- Heat transfer fluid circuit: minimum filling capacity 8.9 l, expansion tank 19.9 l.
Control, installation and operation
The Pilot ONE controller with POKO ONE control output provides Ethernet, USB (host and device) and RS232 interfaces, plus a Pt100 external sensor connection. The unit is IP20 and must be installed in ambient temperature 5–40 °C, outside ATEX zones. Electrical supply is 400 V 3~ 50 Hz, max current 48 A, fusing 3×50 A; three-phase devices below 63 A are delivered with cable but without a plug. Leakage current exceeds 3.5 mA, so protective earthing and RCD selection must account for this. Voltage tolerance is ±5% with simultaneous frequency tolerance ±2%, and the combination of -5% voltage with +2% frequency is not allowed. The unit must be transported and stored upright only, and an emptied unit may be moved; casters are not for transport and carry only 25% of total mass symmetrically. Leveling feet must be activated and parking brakes engaged before commissioning. For externally closed applications the expansion vessel must remain unlocked; for externally open applications it must be locked. Allow about 2 hours acclimation when moving between cold and warm environments before power-on. The cooling water supply should be shut off even for short downtimes such as overnight.
Integration & Operating Notes
The cooling water circuit requires G3/4 male connections and a supply between 5 °C and 20 °C inlet temperature, with differential pressure of 1–4 bar and maximum pressure 6 bar. Lower inlet temperatures require insulating the cooling water pipes to prevent condensation. Rated cooling power is valid only at 20 °C room temperature, 15 °C cooling water inlet and 1 bar differential pressure; higher cooling water temperature reduces cooling power. Shut off the cooling water supply even for short downtimes such as overnight.
In Process Safety mode, when the set overtemperature trigger value is reached the controller releases maximum cooling capacity instead of switching off all poles. This mode requires the compressor to be set to Permanently ON. Power Failure Auto resumes temperature control automatically after a power outage if it was active; choose the power-interruption behavior according to whether unattended restart is acceptable for the process.
Hoses and connections must be periodically checked for leaks and quality and replaced as needed. Work on the coolant circuit must be carried out by approved refrigeration/air-conditioning system contractors. The responsible body must install a condensation water / heat transfer fluid drip tray below the unit; national legislation may prescribe it. The unit must not be installed or started within an ATEX zone; explosion protection requires an Ex px cabinet.
Selection & Integration Q&A
Choose the 640w when you need 24 kW heating and up to 196 l/min pump delivery for large or high-flow closed loops. The 5xx models (510w, 515w, 520w, 525) are smaller-capacity alternatives; select them when 24 kW heating and 196 l/min are not required and a more compact unit is acceptable.
Provide a 400 V 3~ 50 Hz supply with 3×50 A fusing and a suitable mating plug (cable delivered without plug). Account for leakage current >3.5 mA in RCD selection and earthing. Voltage tolerance ±5% with frequency ±2%, but -5% voltage with +2% frequency is not allowed.
Cooling water: G3/4 male connections, inlet 5–20 °C, differential pressure 1–4 bar, max 6 bar; insulate pipes if inlet below ambient to prevent condensation. Ambient: 5–40 °C, IP20, outside ATEX zones. Rated cooling power assumes 20 °C room, 15 °C water inlet, 1 bar differential.
Base delivery excludes the three-phase mating plug. Plan for a drip tray (may be required by local regulations), periodic hose/connection inspection and replacement, and cooling water shut-off for short downtimes. Refrigerant-circuit work requires approved contractors. Heat transfer fluid must be selected for the -60 to 200 °C range and FL fire-point ≥65 °C if flammable.