Peter Huber Kältemaschinenbau Unistat GL 530w Dynamisches
Peter Huber Kältemaschinenbau Unistat GL 530w Dynamisches — Temperature control units with Noise level 61 dB.
The Unistat GL 530w Dynamisches is a water-cooled, CO2 (R-744) refrigerant free-standing temperature control unit with a magnetically coupled stainless-steel pump and Pilot ONE controller, covering -50 to 200 °C. Within the Unistat 5xx Dynamisches series it is the water-cooled GL variant, distinguished from air-cooled siblings by its G3/4 cooling-water circuit. It serves dynamic tempering of externally closed or open process circuits requiring 6 kW heating and up to 10 kW cooling at 0 °C.
Peter Huber Kältemaschinenbau Unistat Series — Model Comparison & Selection
| Model | Noise level, dB | Display resolution | Heating capacity, W | Pump connection | Pump type | Temperature range, °C |
|---|---|---|---|---|---|---|
| Unistat GL 530w Dynamisches Current | 61 | 0, 01 | 6000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat 510w Dynamisches | 60 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat 515w Dynamisches | — | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat 520w Dynamisches | 61 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 525 Dynamisches | 56 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 525w Dynamisches | 61 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 527w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 530w Dynamisches | 59 | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 540w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 545w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 610w Dynamisches | 62 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 615w Dynamisches | 62 | 0, 01 | 12000 | M30x1, 5 AG male | Pressure pump, variable | -60–200 |
| Unistat 620w Dynamisches | 68 | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 625w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 630w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 635w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 640w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 645w Dynamisches | — | 0, 01 | 36000 | flange DN32 PN10/40 EN10 | magnetically coupled, st | -60–200 |
| Unistat 650w Dynamisches | 73 | 0, 01 | 48000 | flange DN32 PN10/40 EN10 | magnetically coupled, st | -60–200 |
| Unistat 680w Dynamisches | — | 0, 01 | 96000 | DN50 PN16 (DIN EN 1092-1 | magnetically coupled, st | -60–200 |
| Unistat GL 535w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 540w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 550w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 560w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 570w Dynamisches | — | 0, 01 | 48000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P530w Dynamisches | 61 | 0, 01 | 6000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P535w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P540w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P550w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P560w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P570w Dynamisches | — | 0, 01 | 48000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat P510 Dynamisches | 60 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat P510w Dynamisches | 60 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat P515w Dynamisches | — | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat P520 Dynamisches | — | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P520w Dynamisches | 61 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P525 Dynamisches | 56 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P525w Dynamisches | 61 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P527w Dynamisches | 57 | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P530w Dynamisches | 62 | 0.01 | 12000 | M38x1,5 AG male | magnetically coupled, st | -55–250 |
| Unistat P540w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P545w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P610 Dynamisches | — | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P610w Dynamisches | 62 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P615 Dynamisches | — | 0, 01 | 12000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P615w Dynamisches | 62 | 0, 01 | 12000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P620w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P625w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P630w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P635w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P645w Dynamisches | — | 0, 01 | 36000 | flange DN32 PN10/40 EN10 | magnetically coupled, st | -60–200 |
| Unistat P650w Dynamisches | — | 0, 01 | 48000 | flange DN32 PN10/40 EN10 | magnetically coupled, st | -60–200 |
Full specifications
| Noise level | 61 dB(A) |
| Control output | POKO ONE |
| Heating capacity | 6 kW |
| Pump connection | M38x1, 5 AG male |
| Pump speed adjustable | Yes |
| Pump type | magnetically coupled, stainless steel |
| External sensor connection | Pt100 |
| Temperature range | -50...200 °C |
| Power supply | 400V 3~ 50Hz |
| Controller | Pilot ONE |
| Display resolution | 0, 01 K |
| Digital interface | Ethernet, USB (Host u. Device), RS232 |
| Maximum viscosity | 100 mm²/s |
| Ambient temperature limit | 5...40 °C |
| Cooling water connection | G3/4 male |
| Cooling water consumption | 620 l/h (at 15°C, flow 0°C) |
| Cooling water differential pressure | 1 bar (min.) |
| Cooling Water Pressure | 6 bar (max.) |
| Protection rating | IP20 |
| Safety class | III / FL |
Description
Construction and series positioning
- Free-standing water-cooled unit (suffix w) using refrigerant R-744 (A1, H280, GWP 1); GL designates CO2 refrigerant per the manual's model-name key.
- Overall dimensions 730 x 804 x 1738 mm (WxDxH); IP20 protection; safety class III / FL.
- Magnetically coupled stainless-steel circulation pump, speed-adjustable, with M38x1.5 male pump connection (bore shape Y, 60°, DIN 3863).
- Sibling models 510w, 515w, 520w and 525 Dynamisches share the Dynamisches series; this GL 530w is the water-cooled CO2 variant, so cooling-water plumbing is mandatory where air-cooled siblings need only clearance.
Thermal behavior and media
- Working range -50 to 200 °C; display resolution 0.01 K; external Pt100 sensor connection.
- Heating capacity 6 kW. Cooling power with ethanol: 10 kW at 0 °C, 7 kW at -20 °C, 2.5 kW at -40 °C, 1.5 kW at -50 °C — low-temperature duty must be sized against this falling curve.
- Pump: max delivery 196 l/min, max delivery pressure 2.5 bar; flow falls as system pressure drop rises, so the process circuit must be matched to the pump curve.
- Heat transfer fluid kinematic viscosity must not exceed 100 mm²/s at operating temperature.
- Minimum filling capacity 8.9 l; expansion tank 19.9 l.
Installation, control and operation
- 400 V 3~ 50 Hz supply; voltage tolerance ±5% only with simultaneous frequency tolerance ±2%, and combinations such as -5% voltage with +2% frequency are not permitted.
- Cooling water: G3/4 male connection; intake temperature 5–20 °C; differential pressure min. 1 bar (datasheet also states max. 4 bar differential); max. cooling water pressure 6 bar; consumption 620 l/h at 15 °C, flow 0 °C. Below-dew-point operation requires insulated cooling-water pipes.
- Pilot ONE controller with POKO ONE control output; interfaces Ethernet, USB host and device, RS232; touchscreen operation with LED flow diagram and status indicators.
- Externally closed applications: expansion vessel must remain unlocked; externally open (bath) applications: expansion vessel must be locked.
- Overtemperature protection (OT limit heating, OT expansion vessel, Process Safety) must be set and function-tested in setup mode; Process Safety releases maximum cooling at the OT trigger and requires the compressor set to Permanently ON.
- Power-interruption response configurable: Off/Standby (default) or automatic restart; Power Failure Auto resumes an active process after outage.
- EN55011 Class A, Group 1 disturbance classification — EMC measures may be needed in sensitive environments.
Integration & Operating Notes
The unit requires 400 V 3~ 50 Hz and permits ±5% voltage only together with ±2% frequency; the datasheet explicitly forbids combinations such as -5% voltage with +2% frequency. The site distribution and any upstream transformer or generator must be checked against this combined envelope before connection, and hard-wiring must be performed by an electrician.
The water circuit needs a G3/4 male connection, intake temperature between 5 and 20 °C, minimum 1 bar differential pressure (datasheet also lists max. 4 bar differential) and no more than 6 bar static pressure, with 620 l/h consumption at 15 °C supply and 0 °C flow. Below-dew-point supply requires insulating the cooling-water pipes to prevent condensation.
The magnetically coupled stainless-steel pump is limited to a maximum kinematic viscosity of 100 mm²/s, so the heat transfer fluid must be selected so that its viscosity at the lowest operating temperature stays within this limit; otherwise circulation performance drops and the pump may be overloaded.
For an externally closed application the expansion vessel must remain unlocked — locking it causes overpressure damage. For an externally open (bath) application the expansion vessel must be locked to prevent fluid loss. The installation must therefore be classified before commissioning, and the isolating sleeve or shut-off valves set accordingly.
In Process Safety mode the controller releases maximum cooling capacity at the overtemperature trigger instead of switching off all poles, but this mode requires the compressor to be set to Permanently ON. The OT limit heating and OT expansion vessel values must be set and function-tested in setup mode before the process runs.
After power interruption the Pilot ONE can be set to Off/Standby (default, manual restart) or ON/Temperature control active (automatic restart with a short INFO window to cancel). Power Failure Auto resumes an active process after outage. The choice must match whether unattended restart is acceptable for the process.
The unit must be transported and stored upright only — horizontal transport damages the compressor — and only after draining. Casters, if present, are not suitable for transport and carry only 25% of total mass symmetrically; an industrial truck is required. Leveling feet must be activated and parking brakes engaged before commissioning, and about 2 hours acclimation is needed after a cold-to-warm move before power-on.
The unit must not be installed or started within an ATEX zone; explosion protection requires a separate Ex px cabinet. The responsible body must install a condensation-water / heat-transfer-fluid drip tray below the unit, and national legislation may prescribe it. Ambient temperature must stay between 5 and 40 °C.
The cooling water supply should be shut off even for short downtimes such as overnight to avoid water damage and unnecessary load on the circuit. Hoses and hose connections must be checked periodically for leaks and quality and replaced as required; the hat-type strainer/dirt trap requires draining the cooling circuit for cleaning, and refrigerant-circuit work must be done by approved refrigeration/air-conditioning contractors.
Selection & Integration Q&A
Pick the GL 530w when a CO2 (R-744) refrigerant and water cooling are required and a G3/4 cooling-water supply of 5–20 °C at 1–4 bar differential is available. Air-cooled 510w/520w siblings avoid water plumbing but reject heat to room air; the 525 Dynamisches is a different capacity point in the series. Choose by refrigerant, cooling medium and required cooling power at your lowest process temperature.
The pump outlet is M38x1.5 male (bore shape Y, 60°, DIN 3863), so tempering hoses need compatible ball sockets and sleeve nuts. The pump delivers max. 196 l/min at max. 2.5 bar, with flow falling as pressure drop rises — size the external circuit against the pump curve. Minimum filling is 8.9 l with a 19.9 l expansion tank, and fluid viscosity must stay ≤100 mm²/s.
Ambient must be 5–40 °C, the unit must not sit in an ATEX zone, and a drip tray is required below it. Transport upright and emptied; casters are not for transport. Allow ~2 h acclimation after a cold/warm move. Supply is 400 V 3~ 50 Hz with ±5% voltage only at ±2% frequency. Cooling water must be 5–20 °C, 1–4 bar differential, max. 6 bar.
Base delivery excludes cooling-water hoses and fittings (G3/4 male), process hoses with M38x1.5 ball sockets, heat transfer fluid, and the drip tray. Plan periodic hose/connection inspection and replacement, cooling-water shutoff for overnight downtime, strainer cleaning with circuit drain, and refrigerant work only by approved contractors. The optional gas detection sensor and processing unit are installed by the operating company.