Peter Huber Kältemaschinenbau Unistat GL P530w Dynamisches
Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau Unistat GL P530w Dynamisches

Peter Huber Kältemaschinenbau Unistat GL P530w Dynamisches — Temperature control units with Noise level 61 dB.

The Unistat GL P530w Dynamisches is a water-cooled, CO2-refrigerant (GL) free-standing temperature control unit with a magnetically coupled stainless-steel pump and Pilot ONE controller, covering -50 to 200 °C with 6 kW heating. Its 'P' designation targets applications with high pressure drop, delivering 87 l/min at 4.0 bar. It serves precise temperature control of externally closed circuits in pilot-plant and process automation.

Noise level
61 dB

Peter Huber Kältemaschinenbau Unistat Series — Model Comparison & Selection

Model Noise level, dBDisplay resolutionHeating capacity, WPump connectionPump typeTemperature range, °C
Unistat GL P530w Dynamisches Current 610, 016000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat 510w Dynamisches 600, 016000M30x1, 5 AG malemagnetically coupled, st-50–250
Unistat 515w Dynamisches —0, 016000M30x1, 5 AG malemagnetically coupled, st-50–250
Unistat 520w Dynamisches 610, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat 525 Dynamisches 560, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat 525w Dynamisches 610, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat 527w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat 530w Dynamisches 590, 0112000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat 540w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat 545w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat 610w Dynamisches 620, 016000M30x1, 5 AG malemagnetically coupled, st-60–200
Unistat 615w Dynamisches 620, 0112000M30x1, 5 AG malePressure pump, variable -60–200
Unistat 620w Dynamisches 680, 0112000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat 625w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat 630w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat 635w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat 640w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat 645w Dynamisches —0, 0136000flange DN32 PN10/40 EN10magnetically coupled, st-60–200
Unistat 650w Dynamisches 730, 0148000flange DN32 PN10/40 EN10magnetically coupled, st-60–200
Unistat 680w Dynamisches —0, 0196000DN50 PN16 (DIN EN 1092-1magnetically coupled, st-60–200
Unistat GL 530w Dynamisches 610, 016000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL 535w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL 540w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL 550w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL 560w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL 570w Dynamisches —0, 0148000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P535w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P540w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P550w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P560w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P570w Dynamisches —0, 0148000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat P510 Dynamisches 600, 016000M30x1, 5 AG malemagnetically coupled, st-50–250
Unistat P510w Dynamisches 600, 016000M30x1, 5 AG malemagnetically coupled, st-50–250
Unistat P515w Dynamisches —0, 016000M30x1, 5 AG malemagnetically coupled, st-50–250
Unistat P520 Dynamisches —0, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat P520w Dynamisches 610, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat P525 Dynamisches 560, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat P525w Dynamisches 610, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat P527w Dynamisches 570, 0112000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat P530w Dynamisches 620.0112000M38x1,5 AG malemagnetically coupled, st-55–250
Unistat P540w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat P545w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat P610 Dynamisches —0, 016000M30x1, 5 AG malemagnetically coupled, st-60–200
Unistat P610w Dynamisches 620, 016000M30x1, 5 AG malemagnetically coupled, st-60–200
Unistat P615 Dynamisches —0, 0112000M30x1, 5 AG malemagnetically coupled, st-60–200
Unistat P615w Dynamisches 620, 0112000M30x1, 5 AG malemagnetically coupled, st-60–200
Unistat P620w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat P625w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat P630w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat P635w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat P645w Dynamisches —0, 0136000flange DN32 PN10/40 EN10magnetically coupled, st-60–200
Unistat P650w Dynamisches —0, 0148000flange DN32 PN10/40 EN10magnetically coupled, st-60–200

Full specifications

Core Performance & Functional Specifications
Noise level 61 dB(A)
Control output POKO ONE
Heating capacity 6 kW
Pump connection M38x1, 5 AG male
Pump speed adjustable Yes
Pump type magnetically coupled, stainless steel
External sensor connection Pt100
Temperature range -50...200 °C
Electrical, Power & Drive Specifications
Power supply 400V 3~ 50Hz
Interfaces, Connections & Control
Controller Pilot ONE
Display resolution 0, 01 K
Digital interface Ethernet, USB (Host u. Device), RS232
Materials, Media & Process Compatibility
Maximum viscosity 100 mm²/s
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C
Cooling water connection G3/4 male
Cooling water consumption 620 l/h (at 15°C, flow 0°C)
Cooling water differential pressure 1 bar (min.)
Cooling Water Pressure 6 bar (max.)
Protection rating IP20
Standards, Safety & General Data
Safety class III / FL

Description

Construction and series positioning

Behavior under load

Control, installation and operation

Integration & Operating Notes

Cooling & Media
Cooling water must stay within 5–20 °C and 1–6 bar

Intake temperature must be 5–20 °C with 1–4 bar differential pressure and maximum 6 bar pressure. As cooling-water temperature rises, expect a drop in cooling power and possibly a higher required flow rate. Insulate cooling-water pipes whenever water temperature can fall below the dew point to prevent condensation on the unit.

Unistat GL P530w Technical Data Sheet, page 2
Process Limits
Cooling capacity collapses at low temperature with ethanol

Cooling capacity is 12 kW with Thermooil at 20–200 °C but only 1.5 kW with ethanol at -50 °C. Size the process load against the actual heat-transfer fluid and operating temperature, not against the headline capacity; low-temperature ethanol duty leaves little margin for exothermic or high-dissipation loads.

Unistat GL P530w Technical Data Sheet, page 1
Mounting
Expansion vessel must stay unlocked for closed applications

For externally closed applications the expansion vessel must remain unlocked; locking it will damage the application due to overpressure. Conversely, for externally open (bath) applications the expansion vessel must be locked to prevent fluid loss. Confirm the application type before commissioning and set the vessel state accordingly.

Unistat Operation Manual, Section on Preparations for Operation, page 33
Mounting
Allow ~2 h acclimation before first power-on after a move

When moving the unit between cold and warm environments (or vice versa), let it acclimate for about 2 hours before switching on. Powering up immediately can cause condensation-induced electrical faults. Also transport and store upright only, and move only an emptied unit.

Unistat Operation Manual, Commissioning, page 29
Control & I/O
Process Safety mode needs the compressor set to Permanently ON

In 'Process safety' mode the controller releases maximum cooling capacity at the overtemperature trigger instead of switching off all poles, which protects exothermic processes. This mode requires the compressor to be set to Permanently ON; configure this before relying on the function. The alternative power-interruption behavior (Off/Standby vs ON) determines whether the unit restarts unattended.

Unistat Operation Manual, Setup Mode, page 19–21
Maintenance
Shut off cooling water even for overnight downtime

Close the cooling-water supply even for short downtimes such as overnight to avoid water damage and unnecessary load on the circuit. Periodically check hoses and hose connections for leaks and quality and replace as required; clean the liquefier fins and the hat-type strainer/dirt trap as part of scheduled maintenance.

Unistat Operation Manual, Commissioning / Service and Maintenance, page 29
Process Limits
Not permitted in ATEX zones or for medical/food contact

The unit must not be installed or started within an ATEX zone; explosion protection requires a separate Ex px cabinet. Use with medical devices (e.g. in vitro diagnostic procedures) or for direct foodstuff temperature control is not permissible. Refrigerant-circuit work must be performed by approved refrigeration/air-conditioning contractors.

Unistat Operation Manual, Section 1.3.3 / 1.3.4, page 15–16

Selection & Integration Q&A

When should I choose the GL P530w Dynamisches over the air-cooled 5xx siblings such as the 510w or 520w?

Pick this water-cooled CO2 (GL) 'P' variant when the external circuit has high pressure drop (87 l/min at 4.0 bar) and a facility cooling-water supply of 5–20 °C is available. Air-cooled siblings suit sites without cooling water; non-P variants suit low-pressure-drop circuits.

What must the facility provide for the cooling-water and process connections to mate correctly?

Cooling water: G3/4 male, 5–20 °C, 1–4 bar differential, max 6 bar, 620 l/h at 15 °C. Process pump connection: M38x1.5 male, bore shape Y (60°) per DIN 3863; use ball socket DIN 3863 and sleeve nut DIN 3870. Insulate pipes if below dew point.

What installation and duty-cycle limits apply to siting and restart behavior?

Ambient 5–40 °C, IP20, EMC Class A Group 1 (may restrict residential use), no ATEX zone. Transport upright and emptied; acclimate ~2 h before power-on. Choose Off/Standby or ON restart behavior per whether unattended restart is acceptable.

What maintenance items and accessories are not included in base delivery and must be planned separately?

A condensation/fluid drip tray below the unit is the operator's responsibility and may be legally required. Cooling-water hoses, mating DIN 3863/3870 fittings, and the optional gas detection sensor/processing unit are not base scope; refrigerant work needs approved contractors.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Unistat GL P530w Technical Data Sheet
Datasheet ·98,5 КБ ·2 pp.
View PDF
PDF
Unistat® Operation Manual — Unistat® 5, Unistat® Pilot ONE®
Manual ·3,6 МБ ·100 pp.
View PDF
PDF
Unistat Operation Manual
Manual ·3,7 МБ ·102 pp.
View PDF