Peter Huber Kältemaschinenbau Unistat GL P560w Dynamisches
Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau Unistat GL P560w Dynamisches

Peter Huber Kältemaschinenbau Unistat GL P560w Dynamisches — Temperature control units.

The Unistat GL P560w Dynamisches is a water-cooled, CO2-refrigerant (GL) free-standing temperature control unit with a magnetically coupled stainless-steel pump and Pilot ONE controller, covering -50 to 200 °C with 24 kW heating. Its 'P' designation targets applications with high pressure drop, distinguishing it from standard 5xx siblings. It serves closed-loop process temperature control in industrial automation.

Peter Huber Kältemaschinenbau Unistat Series — Model Comparison & Selection

Model Noise level, dBDisplay resolutionHeating capacity, WPump connectionPump typeTemperature range, °C
Unistat GL P560w Dynamisches Current —0, 0124000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat 510w Dynamisches 600, 016000M30x1, 5 AG malemagnetically coupled, st-50–250
Unistat 515w Dynamisches —0, 016000M30x1, 5 AG malemagnetically coupled, st-50–250
Unistat 520w Dynamisches 610, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat 525 Dynamisches 560, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat 525w Dynamisches 610, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat 527w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat 530w Dynamisches 590, 0112000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat 540w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat 545w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat 610w Dynamisches 620, 016000M30x1, 5 AG malemagnetically coupled, st-60–200
Unistat 615w Dynamisches 620, 0112000M30x1, 5 AG malePressure pump, variable -60–200
Unistat 620w Dynamisches 680, 0112000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat 625w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat 630w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat 635w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat 640w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat 645w Dynamisches —0, 0136000flange DN32 PN10/40 EN10magnetically coupled, st-60–200
Unistat 650w Dynamisches 730, 0148000flange DN32 PN10/40 EN10magnetically coupled, st-60–200
Unistat 680w Dynamisches —0, 0196000DN50 PN16 (DIN EN 1092-1magnetically coupled, st-60–200
Unistat GL 530w Dynamisches 610, 016000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL 535w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL 540w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL 550w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL 560w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL 570w Dynamisches —0, 0148000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P530w Dynamisches 610, 016000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P535w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P540w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P550w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P570w Dynamisches —0, 0148000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat P510 Dynamisches 600, 016000M30x1, 5 AG malemagnetically coupled, st-50–250
Unistat P510w Dynamisches 600, 016000M30x1, 5 AG malemagnetically coupled, st-50–250
Unistat P515w Dynamisches —0, 016000M30x1, 5 AG malemagnetically coupled, st-50–250
Unistat P520 Dynamisches —0, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat P520w Dynamisches 610, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat P525 Dynamisches 560, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat P525w Dynamisches 610, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat P527w Dynamisches 570, 0112000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat P530w Dynamisches 620.0112000M38x1,5 AG malemagnetically coupled, st-55–250
Unistat P540w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat P545w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat P610 Dynamisches —0, 016000M30x1, 5 AG malemagnetically coupled, st-60–200
Unistat P610w Dynamisches 620, 016000M30x1, 5 AG malemagnetically coupled, st-60–200
Unistat P615 Dynamisches —0, 0112000M30x1, 5 AG malemagnetically coupled, st-60–200
Unistat P615w Dynamisches 620, 0112000M30x1, 5 AG malemagnetically coupled, st-60–200
Unistat P620w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat P625w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat P630w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat P635w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat P645w Dynamisches —0, 0136000flange DN32 PN10/40 EN10magnetically coupled, st-60–200
Unistat P650w Dynamisches —0, 0148000flange DN32 PN10/40 EN10magnetically coupled, st-60–200

Full specifications

Core Performance & Functional Specifications
Control output POKO ONE
Heating capacity 24 kW
Pump connection M38x1, 5 AG male
Pump speed adjustable Yes
Pump type magnetically coupled, stainless steel
External sensor connection Pt100
Temperature range -50...200 °C
Electrical, Power & Drive Specifications
Power supply 400V 3~ 50Hz
Interfaces, Connections & Control
Controller Pilot ONE
Display resolution 0, 01 K
Digital interface Ethernet, USB (Host u. Device), RS232
Materials, Media & Process Compatibility
Maximum viscosity 100 mm²/s
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C
Cooling water connection G3/4 male
Cooling water differential pressure 1 bar (min)
Cooling Water Pressure 6 bar (max)
Protection rating IP20
Standards, Safety & General Data
Safety class III / FL

Description

Construction and series positioning

Working range and media behavior

Installation, connection and control

Integration & Operating Notes

Electrical
Three-phase supply needs a site-fitted plug and tight tolerance

The 400 V 3~ 50 Hz connection is delivered with cable but without a plug for currents below 63 A, so a suitable plug must be sourced and the hard-wired connection made by an electrician. Supply must stay within ±5% voltage with simultaneous ±2% frequency tolerance; opposite-sign deviations are not permitted.

Technical Data Sheet, page 2; Operation Manual, Section on power connection, page 37
Process Limits
Expansion vessel lock state must match the application type

For externally closed applications the expansion vessel must remain unlocked — locking it causes overpressure damage to the application. For externally open (bath) applications the vessel must be locked to prevent fluid loss. Verify the isolating sleeve/valve state before commissioning.

Operation Manual, Section on preparations for operation, page 33
Mounting
Upright transport, acclimation and leveling precede power-on

Transport and store upright only — horizontal transport damages the compressor; move only an emptied unit. Allow about 2 hours acclimation when moving between cold and warm environments before switching on. Activate leveling feet and parking brakes before commissioning; casters are not for transport and carry only 25% of total mass symmetrically.

Operation Manual, Section on commissioning, pages 22 and 29
Environment
ATEX zones and medical/food applications are excluded

The unit must not be installed or started within an ATEX zone; explosion protection requires a separate Ex px cabinet. Use with medical devices (e.g. in vitro diagnostic procedures) or for direct foodstuff temperature control is not permissible. Ambient temperature must stay within 5–40 °C.

Operation Manual, Section 1.3.3, pages 15–16; Technical Data Sheet, page 2

Selection & Integration Q&A

When should I choose the Unistat GL P560w Dynamisches instead of a sibling such as the Unistat 510w or 520w Dynamisches?

Pick the P560w when the application has high pressure drop (the 'P' designation) and you need water cooling with CO2 refrigerant (GL). Siblings like the 510w/520w are standard water-cooled variants without the high-pressure-drop modification; choose them when circuit pressure drop is not the constraint.

What must I provide on the cooling water and process side to integrate this unit?

Provide cooling water at 1 bar minimum differential (max 4 bar differential per datasheet) and no more than 6 bar, through G3/4 male connections, with intake at 5–20 °C and materials compatible with copper, 1.4401, MS, PA, PPE, PTFE and EPDM. Process pipework must mate to the M38x1.5 male pump connection using DIN 3863 ball socket and DIN 3870 sleeve nut.

What mounting and duty-cycle limits does the manual impose on this unit?

Install upright only, allow ~2 h acclimation after temperature changes before power-on, activate leveling feet and parking brakes, and keep ambient at 5–40 °C. Casters are not for transport (25% load only). The unit must not be installed in an ATEX zone, and medical-device or direct-food use is excluded.

What maintenance items and accessories are not included in base delivery and must be planned separately?

A three-phase plug is not supplied (cable only below 63 A), and a condensation/heat transfer fluid drip tray must be installed by the responsible body. Periodic hose inspection/replacement, cooling water shutoff during downtimes, and refrigerant-circuit work by approved contractors must be scheduled; the optional gas detection sensor and processing unit are operating-company scope.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Unistat GL P560w Technical Data Sheet
Datasheet ·98,4 КБ ·2 pp.
View PDF
PDF
Unistat® Operation Manual — Unistat® 5, Unistat® Pilot ONE®
Manual ·3,6 МБ ·100 pp.
View PDF
PDF
Unistat Operation Manual
Manual ·3,7 МБ ·102 pp.
View PDF