Peter Huber Kältemaschinenbau Unistat P520 Dynamisches

Peter Huber Kältemaschinenbau Unistat P520 Dynamisches — Temperature control units.

The Unistat P520 Dynamisches is an air-cooled refrigerated heating circulator with a magnetically coupled stainless steel pump, built for high-pressure-drop circuits in flow-through chemistry and semiconductor work. Its -55 to 250 °C range and 6 kW heating capacity distinguish it from the water-cooled w-variants of the Unistat 5xx series. It serves as a temperature control source for externally closed or open applications requiring high pump discharge pressure.

Peter Huber Kältemaschinenbau Unistat Series — Model Comparison & Selection

Model Noise level, dBDisplay resolutionHeating capacity, WPump connectionPump typeTemperature range, °C
Unistat P520 Dynamisches Current —0, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat 510w Dynamisches 600, 016000M30x1, 5 AG malemagnetically coupled, st-50–250
Unistat 515w Dynamisches —0, 016000M30x1, 5 AG malemagnetically coupled, st-50–250
Unistat 520w Dynamisches 610, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat 525 Dynamisches 560, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat 525w Dynamisches 610, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat 527w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat 530w Dynamisches 590, 0112000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat 540w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat 545w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat 610w Dynamisches 620, 016000M30x1, 5 AG malemagnetically coupled, st-60–200
Unistat 615w Dynamisches 620, 0112000M30x1, 5 AG malePressure pump, variable -60–200
Unistat 620w Dynamisches 680, 0112000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat 625w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat 630w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat 635w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat 640w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat 645w Dynamisches —0, 0136000flange DN32 PN10/40 EN10magnetically coupled, st-60–200
Unistat 650w Dynamisches 730, 0148000flange DN32 PN10/40 EN10magnetically coupled, st-60–200
Unistat 680w Dynamisches —0, 0196000DN50 PN16 (DIN EN 1092-1magnetically coupled, st-60–200
Unistat GL 530w Dynamisches 610, 016000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL 535w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL 540w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL 550w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL 560w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL 570w Dynamisches —0, 0148000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P530w Dynamisches 610, 016000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P535w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P540w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P550w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P560w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P570w Dynamisches —0, 0148000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat P510 Dynamisches 600, 016000M30x1, 5 AG malemagnetically coupled, st-50–250
Unistat P510w Dynamisches 600, 016000M30x1, 5 AG malemagnetically coupled, st-50–250
Unistat P515w Dynamisches —0, 016000M30x1, 5 AG malemagnetically coupled, st-50–250
Unistat P520w Dynamisches 610, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat P525 Dynamisches 560, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat P525w Dynamisches 610, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat P527w Dynamisches 570, 0112000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat P530w Dynamisches 620.0112000M38x1,5 AG malemagnetically coupled, st-55–250
Unistat P540w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat P545w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat P610 Dynamisches —0, 016000M30x1, 5 AG malemagnetically coupled, st-60–200
Unistat P610w Dynamisches 620, 016000M30x1, 5 AG malemagnetically coupled, st-60–200
Unistat P615 Dynamisches —0, 0112000M30x1, 5 AG malemagnetically coupled, st-60–200
Unistat P615w Dynamisches 620, 0112000M30x1, 5 AG malemagnetically coupled, st-60–200
Unistat P620w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat P625w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat P630w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat P635w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat P645w Dynamisches —0, 0136000flange DN32 PN10/40 EN10magnetically coupled, st-60–200
Unistat P650w Dynamisches —0, 0148000flange DN32 PN10/40 EN10magnetically coupled, st-60–200

Full specifications

Core Performance & Functional Specifications
Control output POKO ONE
Expansion volume 17 l
Heating capacity 6 kW
Pump connection M30x1, 5 AG male
Pump speed adjustable Yes
Pump type magnetically coupled, stainless steel
External sensor connection Pt100
Temperature range -55...250 °C
Electrical, Power & Drive Specifications
Power supply 400V 3~ 50Hz
Interfaces, Connections & Control
Controller Pilot ONE
Display resolution 0, 01 K
Digital interface Ethernet, USB (Host u. Device), RS232
Materials, Media & Process Compatibility
Maximum viscosity 50 mm²/s
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C
Protection rating IP20
Standards, Safety & General Data
Safety class III / FL

Description

Construction and series positioning

Working range and media

Installation, control and operation

Integration & Operating Notes

Electrical
Site supply must match 400 V 3~ 50 Hz and linked tolerances

The unit is factory-configured for 400 V three-phase 50 Hz and the voltage/frequency tolerances are coupled: ±5% voltage is permitted only with ±2% frequency, and -5% voltage with +2% frequency is explicitly not allowed. Verify the site supply against this combined rule before delivery, since a mismatch cannot be corrected by a simple plug change.

Datasheet, Technical Specifications; Instruction Manual, Section 1.8
Mounting
Do not install or start the unit inside an ATEX zone

The temperature control unit must not be installed or started up within an ATEX zone; without an Ex px cabinet the unit and accessories are not protected against explosion. Explosion-protected operation requires the separate ATEX annex and only the model and serial number stated on the Ex px cabinet rating plate is suitable.

Instruction Manual, Section 1.3.3
Mounting
Plan room ventilation for air-cooled condenser heat rejection

The air-cooled condenser rejects heat to ambient air, so the installation room needs adequate ventilation and the room heat load must be included in HVAC planning. Cooling capacity ratings assume 20 °C room temperature and drop as ambient temperature rises; operation is permitted only between 5 and 40 °C ambient.

Datasheet, Product Overview and Technical Specifications
Process Limits
Match expansion vessel lock state to open or closed application

For externally closed applications the expansion vessel must remain unlocked; locking it will damage the application due to overpressure. For externally open (bath) applications the expansion vessel must be locked to prevent fluid loss. Confirm the application type before commissioning and set the vessel accordingly.

Instruction Manual, Commissioning
Process Limits
Respect 50 mm²/s viscosity limit and 5.1 l minimum fill

The maximum permissible kinematic viscosity of the heat transfer fluid is 50 mm²/s; a higher-viscosity fluid overloads the pump and reduces circulation. The minimum filling capacity is 5.1 l and the expansion tank holds 17 l, so the external circuit volume must be planned so that both the minimum fill and expansion space are satisfied.

Datasheet, Technical Specifications
Control & I/O
Set power-failure restart behavior before unattended operation

The Pilot ONE can be configured so that after a power outage or switch-on the unit stays in Off/Standby (default, manual start required) or automatically resumes temperature control if it was active. Choose the setting according to whether unattended restart is acceptable for the process, and note that Process Safety mode requires the compressor set to Permanently ON.

Instruction Manual, Section 1.8.1 and Setup Mode
Maintenance
Inspect hoses and clean condenser fins on a scheduled basis

Hoses and hose connections must be periodically checked for leaks and quality and replaced as required. The manual also specifies cleaning the liquefier fins, cleaning the hat-type strainer/dirt trap, emptying the drip tray, inspecting the mechanical seal, and checking/replacing the heat transfer fluid with circuit rinsing. Work on the coolant circuit must be carried out by approved refrigeration/air-conditioning contractors.

Instruction Manual, Maintenance, Messages and Component Replacement

Selection & Integration Q&A

When should I choose the Unistat P520 Dynamisches instead of the water-cooled 520w or the 525 Dynamisches?

Choose the P520 when the external circuit has a high pressure drop (flow-through chemistry, semiconductor) and air cooling is acceptable. The 520w is the water-cooled equivalent for sites without room-air heat rejection capacity; the 525 is a different capacity class in the same series.

What must I provide on the process side to connect the P520 to my external circuit?

The pump connection is M30x1.5 male, so hoses or adapters must match this thread. Plan the external loop so total volume satisfies the 5.1 l minimum fill and the 17 l expansion tank, and keep fluid viscosity at or below 50 mm²/s.

What installation and duty-cycle limits apply to the P520 in my lab?

Install only outside ATEX zones, at 5–40 °C ambient with ventilation for the air-cooled condenser, and on leveling feet with parking brakes engaged. Allow about 2 hours acclimation after moving between cold and warm environments before power-on.

What maintenance and accessories are not included with the base unit?

The unit ships with cable but without a plug for three-phase supply below 63 A; the customer supplies the plug. Routine service includes hose inspection/replacement, condenser fin cleaning, strainer cleaning, drip-tray emptying and heat transfer fluid replacement; refrigerant-circuit work requires approved contractors.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Unistat P520 Temperature Control System Datasheet
Datasheet ·30,9 КБ ·2 pp.
View PDF
PDF
Unistat® Operation Manual — Unistat® 5, Unistat® Pilot ONE®
Manual ·3,6 МБ ·100 pp.
View PDF
PDF
Unistat Operation Manual
Manual ·3,7 МБ ·102 pp.
View PDF