Peter Huber Kältemaschinenbau Unichiller 040Tw
Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau Unichiller 040Tw

Peter Huber Kältemaschinenbau Unichiller 040Tw — Recirculating chillers with Noise level 70 dB.

The Unichiller 040Tw is a water-cooled recirculating chiller for externally closed circuits, operating from -10 to 40 °C with a Pilot ONE controller. Its 70 dB(A) noise level and 134 kg free-standing housing distinguish it from the quieter 030Tw and the air-cooled 040T siblings. It serves as a central cooling source for laboratory and pilot-scale processes.

Noise level
70 dB

Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection

Model Noise level, dBPump connectionPump typeSafety classTemperature range, °CPower supply
Unichiller 040Tw Current 70G3/4 AG maleBI / NFL-10–40400V 3~ 50Hz
Unichiller 030T 69G3/4 AG maleBI / NFL-10–40460V 3~ 60Hz
Unichiller 030Tw 61G3/4 AG maleBI / NFL-20–40400V 3~ 50Hz
Unichiller 040T 69G3/4 AG maleBI / NFL-10–40400V 3~ 50Hz
Unichiller 040T-H 69G3/4 AG maleBIII / FL-10–100400V 3~ 50Hz
Unichiller 040Tw-H 70G3/4 AG maleBIII / FL-10–100400V 3~ 50Hz
Unichiller 050-H 62G1 1/4 AG maleE1III / FL-20–100400V 3~ 50Hz
Unichiller 050w-H 62G1 1/4 AG maleE1III / FL-20–100460V 3~ 60Hz
Unichiller 055T —G1 1/4 AG maleC3I / NFL-20–40400V 3~ 50Hz
Unichiller 055T-H 74G1 1/4 AG maleC3III / FL-20–100400V 3~ 50Hz
Unichiller 055Tw —G1 1/4 AG maleC3I / NFL-20–40400V 3~ 50Hz
Unichiller 060T —G1 1/4 AG maleC3I / NFL-20–40400V 3~ 50Hz
Unichiller 060T-H —G1 1/4 AG maleC3III / FL-20–100400V 3~ 50Hz
Unichiller 060Tw-H —G1 1/4 AG maleC3III / FL-20–100400V 3~ 50Hz
Unichiller 070T-H 66G1 1/4 AG maleC3III / FL-10–100400V 3~ 50Hz
Unichiller 070Tw-H —G1 1/4 AG maleC3III / FL-10–100400V 3~ 50Hz
Unichiller 075w —G1 1/4 AG maleE1I / NFL-20–40400V 3~ 50Hz
Unichiller 075w-H —G1 1/4 AG maleE1III / FL-20–100400V 3~ 50Hz
Unichiller 100-H 58G1 1/4 AG maleE1III / FL-20–100460V 3~ 60Hz
Unichiller 100T —G1 1/4 AG maleC3I / NFL-20–40400V 3~ 50Hz
Unichiller 100T-H —G1 1/4 AG maleC3III / FL-20–100400V 3~ 50Hz
Unichiller 100Tw 65G1 1/4 AG maleC3I / NFL-20–40400V 3~ 50Hz
Unichiller GL 035w —G1 1/4 AG malePressure pump, speed notI / NFL-20–40460V 3~ 60Hz
Unichiller GL 050w —G1 1/4 AG malePressure pump, speed notI / NFL-20–40460V 3~ 60Hz
Unichiller GL 075 —G1 1/4 AG malePressure pump, speed notI / NFL-20–40460V 3~ 60Hz
Unichiller GL 075w —G1 1/4 AG malePressure pump, speed notI / NFL-20–40460V 3~ 60Hz
Unichiller GL 100w —G1 1/4 AG malePressure pump, speed notI / NFL-20–40400V 3~ 50Hz
Unichiller P050 62G1 1/4 AG maleE2I / NFL-20–40400V 3~ 50Hz
Unichiller P050w 62G1 1/4 AG maleE2I / NFL-20–40400V 3~ 50Hz
Unichiller P050w-H 62G1 1/4 AG maleE2III / FL-20–100—
Unichiller P075 61G1 1/4 AG maleE2I / NFL-20–40400V 3~ 50Hz
Unichiller P075w —G1 1/4 AG maleE2I / NFL-20–40400V 3~ 50Hz
Unichiller P075w-H —G1 1/4 AG maleE2III / FL-20–100400V 3~ 50Hz
Unichiller P100 —G1 1/4 AG maleE2I / NFL-20–40460V 3~ 60Hz
Unichiller P100-H —G1 1/4 AG maleE2III / FL-20–100400V 3~ 50Hz
Unichiller P100w 58G1 1/4 AG maleE2I / NFL-20–40400V 3~ 50Hz
Unichiller P100w-H 58G1 1/4 AG maleE2III / FL-20–100400V 3~ 50Hz

Full specifications

Core Performance & Functional Specifications
Noise level 70 dB(A)
Expansion volume 4 l
Pump connection G3/4 AG male
Pump speed adjustable no
Pump type B
External sensor connection Pt100
Temperature range -10...40 °C
Dimensions, Weight & Mechanical Design
Weight 134 kg
Electrical, Power & Drive Specifications
Power supply 400V 3~ 50Hz
Interfaces, Connections & Control
Controller Pilot ONE
Digital interface Ethernet, USB (Host u. Device), RS232
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C
Cooling water connection G1/2 male
Cooling water consumption 32 л/час (at 15°C, flow -10°C)
at 15°C, flow 0°C: 70 l/h · at 15°C, flow 15°C: 132 l/h
Cooling water differential pressure 1 bar
Cooling Water Pressure 6 bar
Protection rating IP20
Standards, Safety & General Data
Safety class I / NFL

Description

Construction and series positioning

Working range and media behavior

Control, installation and operation

Integration & Operating Notes

Mounting
Maintain 50–200 cm wall clearance per side for service access

Free-standing models require a wall clearance of 50 to 200 cm on either side so that maintenance and refrigerant-circuit work can be performed. Plan the footprint before routing hoses and cables, and keep the area below the unit clear of electrical lines that could be reached by condensation.

Unichiller Operation Manual, Installation
Electrical
Provide a 3x10 A three-phase supply and a site-fitted plug

The 040Tw draws from a 400 V 3~ 50 Hz supply protected at 3x10 A. Because three-phase devices below 63 A ship with a cable but without a plug, the installer must procure and fit a suitable plug. Verify voltage within ±5% and frequency within ±2% simultaneously before commissioning.

Unichiller 040Tw Technical Data, Electrical
Process Limits
Cooling water must be 5–20 °C at 1–6 bar differential pressure

The water-cooled circuit needs a cooling-water supply between 5 °C and 20 °C intake temperature, at least 1 bar differential pressure and no more than 6 bar static pressure. Warmer water reduces cooling capacity and raises the required flow rate, so size the supply for the worst-case condition at your site.

Unichiller 040Tw Technical Data, Cooling Water
Control & I/O
Configure power-failure response to match process restart logic

The Pilot ONE allows the power-failure response to be set to OFF/Standby, ON or Power Failure Auto. Choose the setting that matches your process: automatic restart may be unsafe for exothermic reactions, while manual restart may interrupt long unattended runs. Document the chosen mode in the control narrative.

Unichiller Operation Manual, Normal Operation
Safety
Process Safety mode releases full cooling on OT trigger

In Process Safety mode the controller releases maximum cooling capacity when the overtemperature protection trigger value is reached, instead of switching off all poles. This is intended for exothermic processes where cutting cooling would cause runaway temperatures; confirm the OT setpoint and sensor placement before enabling it.

Unichiller Operation Manual, Safety
Maintenance
Shut off cooling water even for overnight downtime

The cooling water supply must be shut off during any downtime, including overnight, to prevent water damage and corrosion. Add this step to the shift handover procedure. Refrigerant-circuit work is restricted to approved refrigeration/air-conditioning contractors.

Unichiller Operation Manual, Operation; Maintenance
Maintenance
Monitor fluid level via the digital indicator as a routine check

The atmospheric open expansion tank (4 l) is fitted with a digital level indicator. Level monitoring is part of routine checks; a falling level indicates a leak or evaporation and must be investigated before the pump runs dry. Only use thermal fluid compatible with the wetted materials.

Unichiller 040Tw Technical Data, Product Overview
Environment
Indoor use only, 5–40 °C ambient, not for ATEX zones

The unit is rated IP20 and may only be operated indoors at 5 to 40 °C ambient with illuminance of at least 300 lx and up to 2000 m altitude. It is not explosion-protected and must not be installed or started up inside an ATEX zone. Check the R-449A charge against room volume to stay within the refrigerant limit per m³.

Unichiller Operation Manual, Installation; Technical Data

Selection & Integration Q&A

When should I choose the 040Tw over the air-cooled 040T or the smaller 030Tw?

Choose the 040Tw when a cooling-water supply is available and the 040 size is needed; it is water-cooled and rated 70 dB(A). The air-cooled 040T avoids the water connection but is rated 69 dB(A). The 030Tw is smaller and quieter at 61 dB(A) but has less capacity.

What cooling-water supply and piping must be provided for the 040Tw?

Provide cooling water at 5–20 °C intake, 1 bar minimum differential pressure and 6 bar maximum, connected via G1/2 male fittings. Consumption at 15 °C water is 70 l/h at 0 °C flow, 32 l/h at -10 °C and 132 l/h at 15 °C. Insulate pipes below the condensation point.

What are the site and duty-cycle limits for installing the 040Tw?

Install indoors at 5–40 °C ambient, IP20, at least 300 lx illuminance and up to 2000 m altitude, with 50–200 cm wall clearance per side. It is not ATEX-rated. Activate leveling feet and parking brakes before start-up, and shut off cooling water for any downtime.

What is not included in the base delivery and what maintenance is required?

Three-phase devices below 63 A ship with a cable but without a plug, so a site-fitted plug is required. Routine maintenance includes checking the digital level indicator on the 4 l expansion tank and shutting off cooling water during downtime; refrigerant work must be done by approved contractors.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Unichiller Operation Manual
Manual ·2,8 МБ ·82 pp.
View PDF
PDF
Unichiller 040Tw Technical Data
Datasheet ·63,8 КБ ·2 pp.
View PDF