Peter Huber Kältemaschinenbau Unistat 540w Dynamisches
Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau Unistat 540w Dynamisches

Peter Huber Kältemaschinenbau Unistat 540w Dynamisches — Temperature control units.

The Unistat 540w Dynamisches is a water-cooled, free-standing temperature control unit in the Unistat 5xx series, covering -55 to 250 °C with 24 kW heating and a magnetically coupled stainless-steel pump. Its 55 A three-phase draw and 1480 l/h cooling-water demand distinguish it from smaller siblings, suiting high-capacity process temperature control.

Peter Huber Kältemaschinenbau Unistat Series — Model Comparison & Selection

Model Noise level, dBDisplay resolutionHeating capacity, WPump connectionPump typeTemperature range, °C
Unistat 540w Dynamisches Current —0, 0124000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat 510w Dynamisches 600, 016000M30x1, 5 AG malemagnetically coupled, st-50–250
Unistat 515w Dynamisches —0, 016000M30x1, 5 AG malemagnetically coupled, st-50–250
Unistat 520w Dynamisches 610, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat 525 Dynamisches 560, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat 525w Dynamisches 610, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat 527w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat 530w Dynamisches 590, 0112000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat 545w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat 610w Dynamisches 620, 016000M30x1, 5 AG malemagnetically coupled, st-60–200
Unistat 615w Dynamisches 620, 0112000M30x1, 5 AG malePressure pump, variable -60–200
Unistat 620w Dynamisches 680, 0112000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat 625w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat 630w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat 635w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat 640w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat 645w Dynamisches —0, 0136000flange DN32 PN10/40 EN10magnetically coupled, st-60–200
Unistat 650w Dynamisches 730, 0148000flange DN32 PN10/40 EN10magnetically coupled, st-60–200
Unistat 680w Dynamisches —0, 0196000DN50 PN16 (DIN EN 1092-1magnetically coupled, st-60–200
Unistat GL 530w Dynamisches 610, 016000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL 535w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL 540w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL 550w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL 560w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL 570w Dynamisches —0, 0148000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P530w Dynamisches 610, 016000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P535w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P540w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P550w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P560w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat GL P570w Dynamisches —0, 0148000M38x1, 5 AG malemagnetically coupled, st-50–200
Unistat P510 Dynamisches 600, 016000M30x1, 5 AG malemagnetically coupled, st-50–250
Unistat P510w Dynamisches 600, 016000M30x1, 5 AG malemagnetically coupled, st-50–250
Unistat P515w Dynamisches —0, 016000M30x1, 5 AG malemagnetically coupled, st-50–250
Unistat P520 Dynamisches —0, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat P520w Dynamisches 610, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat P525 Dynamisches 560, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat P525w Dynamisches 610, 016000M30x1, 5 AG malemagnetically coupled, st-55–250
Unistat P527w Dynamisches 570, 0112000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat P530w Dynamisches 620.0112000M38x1,5 AG malemagnetically coupled, st-55–250
Unistat P540w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat P545w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-55–250
Unistat P610 Dynamisches —0, 016000M30x1, 5 AG malemagnetically coupled, st-60–200
Unistat P610w Dynamisches 620, 016000M30x1, 5 AG malemagnetically coupled, st-60–200
Unistat P615 Dynamisches —0, 0112000M30x1, 5 AG malemagnetically coupled, st-60–200
Unistat P615w Dynamisches 620, 0112000M30x1, 5 AG malemagnetically coupled, st-60–200
Unistat P620w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat P625w Dynamisches —0, 0112000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat P630w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat P635w Dynamisches —0, 0124000M38x1, 5 AG malemagnetically coupled, st-60–200
Unistat P645w Dynamisches —0, 0136000flange DN32 PN10/40 EN10magnetically coupled, st-60–200
Unistat P650w Dynamisches —0, 0148000flange DN32 PN10/40 EN10magnetically coupled, st-60–200

Full specifications

Core Performance & Functional Specifications
Control output POKO ONE
Heating capacity 24 kW
Pump connection M38x1, 5 AG male
Pump speed adjustable Yes
Pump type magnetically coupled, stainless steel
External sensor connection Pt100
Temperature range -55...250 °C
Dimensions, Weight & Mechanical Design
Weight 472 kg
Electrical, Power & Drive Specifications
Current consumption 55 A
Power supply 400V 3~ 50Hz
Interfaces, Connections & Control
Controller Pilot ONE
Display resolution 0, 01 K
Digital interface Ethernet, USB (Host u. Device), RS232
Materials, Media & Process Compatibility
Maximum viscosity 100 mm²/s
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C
Cooling water connection G3/4 male
Cooling water consumption 1480 l/h (at 15°C, flow 0°C)
Cooling water differential pressure 1 bar
Cooling Water Pressure 6 bar
Protection rating IP20
Standards, Safety & General Data
Safety class III / FL

Description

Construction and series positioning

Behavior and media

Installation, control and operation

Integration & Operating Notes

Electrical
Size supply and protection for 55 A three-phase draw

The unit requires a 400 V 3~ 50 Hz supply with a 3x63 A fuse and draws up to 55 A. Cable cross-section, upstream protection and the site transformer must be sized for this; the unit arrives with a cable but no plug, so a suitable plug must be provided on site.

Unistat 540w Technical Data, page 2
Electrical
Account for leakage current above 3.5 mA in RCD design

Leakage current exceeds 3.5 mA, which affects the choice of residual-current protection and earthing design. The electrical installer must select RCD type and rating accordingly rather than assuming a standard 30 mA device is suitable.

Unistat 540w Technical Data, page 2
Cooling & Media
Keep cooling water within 5–20 °C and 1–4 bar differential

The unit is designed for cooling water intake between 5 °C and 20 °C; cooling power drops as water temperature rises. Differential pressure must be 1–4 bar and static pressure must not exceed 6 bar. Consumption is 1480 l/h at 15 °C water and 0 °C flow, so the supply pump and piping must sustain that flow.

Unistat 540w Technical Data, page 2
Cooling & Media
Insulate cooling-water pipes below the condensation point

When cooling water temperatures fall below the condensation point, the cooling water pipes inside the unit must be insulated to prevent condensation, corrosion and electrical risk. The cooling circuit contains copper, stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM, so only compatible water may be used.

Unistat 540w Technical Data, page 2
Process Limits
Respect FL fluid fire-point and viscosity limits

Safety class III/FL requires heat transfer fluid with a fire point of at least 65 °C; ethanol is permitted only under supervised operation. Maximum permissible kinematic viscosity is 100 mm²/s, which also bounds pump performance and the choice of fluid at low temperature.

Unistat Operation Manual — Unistat 5, Unistat Pilot ONE, Section 1.7
Mounting
Set expansion vessel lock state to match application type

For externally closed applications the expansion vessel must remain unlocked; locking it causes overpressure damage. For externally open (bath) applications it must be locked to prevent fluid loss. The wrong state at commissioning is a direct damage risk, so verify before filling.

Unistat Operation Manual, page 33
Mounting
Exclude ATEX zones and allow 2 h acclimation before power-on

The unit must not be installed or started within an ATEX zone; explosion protection requires a separate Ex px cabinet. After moving between cold and warm environments, allow about 2 hours acclimation before switching on to avoid condensation-induced electrical faults. Transport upright only and empty.

Unistat Operation Manual — Unistat 5, Unistat Pilot ONE, Sections 1.3.3 and Commissioning
Control & I/O
Configure power-failure restart behavior before unattended use

Pilot ONE can be set to Off/Standby (default, manual start after power returns) or ON/Temperature control active (automatic restart, with a brief INFO allowing cancellation). Choose according to whether unattended restart is acceptable for the process; Process Safety mode additionally requires the compressor set to Permanently ON.

Unistat Operation Manual — Unistat 5, Unistat Pilot ONE, Sections 1.8.1 and 1.7.2
Maintenance
Shut off cooling water during overnight and short downtimes

The cooling water supply should be shut off even for short downtimes such as overnight to prevent water damage and unnecessary load on the cooling water circuit. Hoses and connections must be checked periodically for leaks and quality and replaced as required.

Unistat Operation Manual, page 29
Maintenance
Refrigerant work restricted to approved contractors

Work on the coolant circuit must be carried out by approved refrigeration/air-conditioning system contractors. The circuit is factory-tested tight to 10⁻⁴ Pa m³/s or better, but refrigerant handling, leak monitoring and shipping classification (UN 3358, 3.6 kg charge) remain regulated tasks.

Unistat Operation Manual — Unistat 5, Unistat Pilot ONE, Sections 1.4.1 and 1.4.2

Selection & Integration Q&A

When should I choose the Unistat 540w over the smaller 510w/515w/520w/525 Dynamisches siblings?

Pick the 540w when the process needs the highest heating capacity (24 kW) and the -55…250 °C range at the largest scale in this series; the smaller siblings suit lower loads. The 540w is water-cooled ('w'), so it also requires a 1480 l/h cooling-water supply, unlike air-cooled variants.

What upstream electrical and cooling-water infrastructure must be in place before the 540w can be commissioned?

A 400 V 3~ 50 Hz supply protected at 3x63 A with a site-fitted plug (cable supplied, plug not), RCD design allowing >3.5 mA leakage, and a cooling-water supply of 5–20 °C at 1–4 bar differential, max 6 bar, delivering 1480 l/h through a G3/4 male connection.

What mounting and duty-cycle limits does the manual impose on this unit?

Install indoors, IP20, ambient 5–40 °C, never in an ATEX zone; transport upright and empty, allow ~2 h acclimation after temperature change, activate leveling feet/parking brakes, and provide a drip tray. Not permitted for medical-device or direct foodstuff temperature control.

What maintenance and consumables are required beyond the base delivery?

Base delivery excludes the power plug, mating ball sockets/sleeve nuts per DIN 3863/3870, heat transfer fluid and cooling-water hoses. Plan periodic hose/connection inspection and replacement, liquefier-fin and strainer cleaning, fluid inspection/replacement, and refrigerant work only by approved contractors.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Unistat 540w Technical Data
Datasheet ·86,1 КБ ·2 pp.
View PDF
PDF
Unistat® Operation Manual — Unistat® 5, Unistat® Pilot ONE®
Manual ·3,6 МБ ·100 pp.
View PDF
PDF
Unistat Operation Manual
Manual ·3,7 МБ ·102 pp.
View PDF