Peter Huber Kältemaschinenbau Unichiller 050-H
Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau Unichiller 050-H

Peter Huber Kältemaschinenbau Unichiller 050-H — Recirculating chillers with Noise level 62 dB.

The Unichiller 050-H is a floor-standing recirculating chiller with a 5 kW cooling capacity at 20 °C, a -20 to 100 °C working range, and a 2 kW heater, positioned above the 030/040 siblings in the series. Its E1 pump delivers 48 l/min at zero head and 11 l/min at 3.0 bar through G1 1/4 male connections, serving externally closed process loops.

Noise level
62 dB

Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection

Model Noise level, dBPump connectionPump typeSafety classTemperature range, °CPower supply
Unichiller 050-H Current 62G1 1/4 AG maleE1III / FL-20–100400V 3~ 50Hz
Unichiller 030T 69G3/4 AG maleBI / NFL-10–40460V 3~ 60Hz
Unichiller 030Tw 61G3/4 AG maleBI / NFL-20–40400V 3~ 50Hz
Unichiller 040T 69G3/4 AG maleBI / NFL-10–40400V 3~ 50Hz
Unichiller 040T-H 69G3/4 AG maleBIII / FL-10–100400V 3~ 50Hz
Unichiller 040Tw 70G3/4 AG maleBI / NFL-10–40400V 3~ 50Hz
Unichiller 040Tw-H 70G3/4 AG maleBIII / FL-10–100400V 3~ 50Hz
Unichiller 050w-H 62G1 1/4 AG maleE1III / FL-20–100460V 3~ 60Hz
Unichiller 055T —G1 1/4 AG maleC3I / NFL-20–40400V 3~ 50Hz
Unichiller 055T-H 74G1 1/4 AG maleC3III / FL-20–100400V 3~ 50Hz
Unichiller 055Tw —G1 1/4 AG maleC3I / NFL-20–40400V 3~ 50Hz
Unichiller 060T —G1 1/4 AG maleC3I / NFL-20–40400V 3~ 50Hz
Unichiller 060T-H —G1 1/4 AG maleC3III / FL-20–100400V 3~ 50Hz
Unichiller 060Tw-H —G1 1/4 AG maleC3III / FL-20–100400V 3~ 50Hz
Unichiller 070T-H 66G1 1/4 AG maleC3III / FL-10–100400V 3~ 50Hz
Unichiller 070Tw-H —G1 1/4 AG maleC3III / FL-10–100400V 3~ 50Hz
Unichiller 075w —G1 1/4 AG maleE1I / NFL-20–40400V 3~ 50Hz
Unichiller 075w-H —G1 1/4 AG maleE1III / FL-20–100400V 3~ 50Hz
Unichiller 100-H 58G1 1/4 AG maleE1III / FL-20–100460V 3~ 60Hz
Unichiller 100T —G1 1/4 AG maleC3I / NFL-20–40400V 3~ 50Hz
Unichiller 100T-H —G1 1/4 AG maleC3III / FL-20–100400V 3~ 50Hz
Unichiller 100Tw 65G1 1/4 AG maleC3I / NFL-20–40400V 3~ 50Hz
Unichiller GL 035w —G1 1/4 AG malePressure pump, speed notI / NFL-20–40460V 3~ 60Hz
Unichiller GL 050w —G1 1/4 AG malePressure pump, speed notI / NFL-20–40460V 3~ 60Hz
Unichiller GL 075 —G1 1/4 AG malePressure pump, speed notI / NFL-20–40460V 3~ 60Hz
Unichiller GL 075w —G1 1/4 AG malePressure pump, speed notI / NFL-20–40460V 3~ 60Hz
Unichiller GL 100w —G1 1/4 AG malePressure pump, speed notI / NFL-20–40400V 3~ 50Hz
Unichiller P050 62G1 1/4 AG maleE2I / NFL-20–40400V 3~ 50Hz
Unichiller P050w 62G1 1/4 AG maleE2I / NFL-20–40400V 3~ 50Hz
Unichiller P050w-H 62G1 1/4 AG maleE2III / FL-20–100—
Unichiller P075 61G1 1/4 AG maleE2I / NFL-20–40400V 3~ 50Hz
Unichiller P075w —G1 1/4 AG maleE2I / NFL-20–40400V 3~ 50Hz
Unichiller P075w-H —G1 1/4 AG maleE2III / FL-20–100400V 3~ 50Hz
Unichiller P100 —G1 1/4 AG maleE2I / NFL-20–40460V 3~ 60Hz
Unichiller P100-H —G1 1/4 AG maleE2III / FL-20–100400V 3~ 50Hz
Unichiller P100w 58G1 1/4 AG maleE2I / NFL-20–40400V 3~ 50Hz
Unichiller P100w-H 58G1 1/4 AG maleE2III / FL-20–100400V 3~ 50Hz

Full specifications

Core Performance & Functional Specifications
Noise level 62 dB(A)
Expansion volume 48 l
Heating capacity 2 kW
Minimum fill volume 18 l
Pump connection G1 1/4 AG male
Pump speed adjustable no
Pump type E1
External sensor connection Pt100
Temperature range -20...100 °C
Dimensions, Weight & Mechanical Design
Weight 268 kg
Electrical, Power & Drive Specifications
Power supply 400V 3~ 50Hz
Interfaces, Connections & Control
Controller Pilot ONE
Digital interface Ethernet, USB (Host u. Device), RS232
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C
Protection rating IP20
Standards, Safety & General Data
Safety class III / FL

Description

Construction and series positioning

Performance and media behavior

Installation and operation

Integration & Operating Notes

Mounting
Maintain 50–200 cm side clearance for maintenance access

Free-standing models require a wall clearance of 50 to 200 cm on either side to allow maintenance access to the refrigeration circuit and pump. Verify floor loading for the 268 kg unit and confirm doorway clearance for the 740×1160×1165 mm cabinet before delivery.

Unichiller Operation Manual, Installation
Electrical
Provide a site-fitted plug for the 400 V three-phase feed

The unit is supplied with a cable but without a plug because it is a three-phase device below 63 A. The installer must provide a matching 3×16 A protected supply and fit the site plug; the IP20 enclosure also means the connection point must be protected from liquid ingress.

Unichiller 050-H Datasheet, Technical Specifications
Cooling & Media
Check pump curve against loop pressure drop before selection

The E1 pump delivers 48 l/min at zero head but only 11 l/min at 3.0 bar. Because the pump speed is not adjustable, the external circuit's pressure drop at the required flow must be plotted against this curve; a high-resistance loop will reduce flow below the process requirement.

Unichiller 050-H Datasheet, Technical Specifications
Safety
Configure power-failure response for exothermic process safety

The Pilot ONE power-failure response can be set to OFF/Standby, ON, or Power Failure Auto. For exothermic processes, Process Safety mode releases maximum cooling capacity when the overtemperature trigger is reached instead of switching off all poles; the appropriate mode must be selected during commissioning.

Unichiller Operation Manual, Normal Operation
Environment
Do not install in ATEX zones or wet plant rooms

The unit is not explosion-protected and must not be installed or started up inside an ATEX zone. The IP20 rating and 5–40 °C ambient limit rule out washdown areas and hot plant rooms; cooling capacity is quoted at 20 °C room temperature and drops as ambient rises.

Unichiller Operation Manual, Installation; Unichiller 050-H Datasheet

Selection & Integration Q&A

When should I choose the Unichiller 050-H instead of the 030T or 040T siblings?

Choose the 050-H when you need heating to 100 °C (2 kW heater) and the higher 5 kW cooling capacity at 20 °C. The 030/040T siblings lack the H suffix and heater; select them only for cooling-only duty within their smaller capacity.

What adjacent system parts must match the 050-H's hydraulic and electrical interfaces?

Hoses and fittings must match the G1 1/4 male pump connection, and the external loop must be closed with 18–48 l volume. The electrical feed requires a 400 V 3~ 50 Hz supply with 3×16 A fusing and a site-fitted plug, since the unit ships with cable but no plug.

What mounting and duty-cycle limits does the manual impose on the 050-H?

Install indoors only, at 5–40 °C ambient, at least 300 lx illuminance, up to 2000 m altitude, with 50–200 cm side clearance for maintenance. Activate leveling feet or parking brakes before start-up, and shut off cooling water even for overnight downtimes.

What maintenance obligations and non-included accessories apply to the 050-H?

Refrigerant circuit work must be done by approved refrigeration contractors; R-449A leak checks and CO2-equivalent records apply. The base delivery excludes the site plug and external hoses/fittings; the Pilot ONE interfaces (Ethernet, USB, RS232) are built in.