Peter Huber Kältemaschinenbau Unichiller 100-H
Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau Unichiller 100-H

Peter Huber Kältemaschinenbau Unichiller 100-H — Recirculating chillers with Noise level 58 dB.

The Unichiller 100-H is an air-cooled recirculating chiller for externally closed circuits, rated -20 to 100 °C with 2 kW heating and a fixed-speed E1 pump delivering up to 56 l/min at 3.8 bar. Its 48 l expansion volume and 18 l minimum fill distinguish it within the Unichiller series, and it requires a 460 V 3~ 60 Hz supply.

Noise level
58 dB

Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection

Model Noise level, dBPump connectionPump typeSafety classTemperature range, °CPower supply
Unichiller 100-H Current 58G1 1/4 AG maleE1III / FL-20–100460V 3~ 60Hz
Unichiller 030T 69G3/4 AG maleBI / NFL-10–40460V 3~ 60Hz
Unichiller 030Tw 61G3/4 AG maleBI / NFL-20–40400V 3~ 50Hz
Unichiller 040T 69G3/4 AG maleBI / NFL-10–40400V 3~ 50Hz
Unichiller 040T-H 69G3/4 AG maleBIII / FL-10–100400V 3~ 50Hz
Unichiller 040Tw 70G3/4 AG maleBI / NFL-10–40400V 3~ 50Hz
Unichiller 040Tw-H 70G3/4 AG maleBIII / FL-10–100400V 3~ 50Hz
Unichiller 050-H 62G1 1/4 AG maleE1III / FL-20–100400V 3~ 50Hz
Unichiller 050w-H 62G1 1/4 AG maleE1III / FL-20–100460V 3~ 60Hz
Unichiller 055T —G1 1/4 AG maleC3I / NFL-20–40400V 3~ 50Hz
Unichiller 055T-H 74G1 1/4 AG maleC3III / FL-20–100400V 3~ 50Hz
Unichiller 055Tw —G1 1/4 AG maleC3I / NFL-20–40400V 3~ 50Hz
Unichiller 060T —G1 1/4 AG maleC3I / NFL-20–40400V 3~ 50Hz
Unichiller 060T-H —G1 1/4 AG maleC3III / FL-20–100400V 3~ 50Hz
Unichiller 060Tw-H —G1 1/4 AG maleC3III / FL-20–100400V 3~ 50Hz
Unichiller 070T-H 66G1 1/4 AG maleC3III / FL-10–100400V 3~ 50Hz
Unichiller 070Tw-H —G1 1/4 AG maleC3III / FL-10–100400V 3~ 50Hz
Unichiller 075w —G1 1/4 AG maleE1I / NFL-20–40400V 3~ 50Hz
Unichiller 075w-H —G1 1/4 AG maleE1III / FL-20–100400V 3~ 50Hz
Unichiller 100T —G1 1/4 AG maleC3I / NFL-20–40400V 3~ 50Hz
Unichiller 100T-H —G1 1/4 AG maleC3III / FL-20–100400V 3~ 50Hz
Unichiller 100Tw 65G1 1/4 AG maleC3I / NFL-20–40400V 3~ 50Hz
Unichiller GL 035w —G1 1/4 AG malePressure pump, speed notI / NFL-20–40460V 3~ 60Hz
Unichiller GL 050w —G1 1/4 AG malePressure pump, speed notI / NFL-20–40460V 3~ 60Hz
Unichiller GL 075 —G1 1/4 AG malePressure pump, speed notI / NFL-20–40460V 3~ 60Hz
Unichiller GL 075w —G1 1/4 AG malePressure pump, speed notI / NFL-20–40460V 3~ 60Hz
Unichiller GL 100w —G1 1/4 AG malePressure pump, speed notI / NFL-20–40400V 3~ 50Hz
Unichiller P050 62G1 1/4 AG maleE2I / NFL-20–40400V 3~ 50Hz
Unichiller P050w 62G1 1/4 AG maleE2I / NFL-20–40400V 3~ 50Hz
Unichiller P050w-H 62G1 1/4 AG maleE2III / FL-20–100—
Unichiller P075 61G1 1/4 AG maleE2I / NFL-20–40400V 3~ 50Hz
Unichiller P075w —G1 1/4 AG maleE2I / NFL-20–40400V 3~ 50Hz
Unichiller P075w-H —G1 1/4 AG maleE2III / FL-20–100400V 3~ 50Hz
Unichiller P100 —G1 1/4 AG maleE2I / NFL-20–40460V 3~ 60Hz
Unichiller P100-H —G1 1/4 AG maleE2III / FL-20–100400V 3~ 50Hz
Unichiller P100w 58G1 1/4 AG maleE2I / NFL-20–40400V 3~ 50Hz
Unichiller P100w-H 58G1 1/4 AG maleE2III / FL-20–100400V 3~ 50Hz

Full specifications

Core Performance & Functional Specifications
Noise level 58 dB(A)
Expansion volume 48 l
Heating capacity 2 kW
Maximum delivery flow rate 56 l/min (also 3, 8 bar pump pressure)
Minimum fill volume 18 l
Pump connection G1 1/4 AG male
Pump speed adjustable no
Pump type E1
External sensor connection Pt100
Temperature range -20...100 °C
Dimensions, Weight & Mechanical Design
Weight 284 kg
Electrical, Power & Drive Specifications
Power supply 460V 3~ 60Hz
Interfaces, Connections & Control
Controller Pilot ONE
Digital interface Ethernet, USB (Host u. Device), RS232
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C
Protection rating IP20
Standards, Safety & General Data
Safety class III / FL

Description

Construction and series positioning

Behavior and process limits

Installation, connection and control

Integration & Operating Notes

Electrical
Provide UL 489 branch protection upstream of the 460 V feed

The datasheet requires external branch circuit protection according to UL 489. The site must include a listed breaker sized for the 3x16 A three-phase supply; the unit is delivered with a cable but without a plug, so the customer must also provide and wire the connection.

Unichiller 100-H Technical Datasheet, Technical Specifications
Mounting
Keep 50–200 cm clear on either side for service access

Free-standing models require a wall clearance of 50 to 200 cm per side for maintenance. Because the refrigeration machine is air-cooled, this clearance also supports heat rejection; the unit must be indoors at 5–40 °C ambient and at least 300 lx illuminance.

Unichiller Operation Manual, Installation
Process Limits
Use only with an externally closed circuit

The chiller is designed for externally closed applications. The external loop volume must be considered against the 18 l minimum filling capacity and 48 l expansion volume; open-loop or once-through cooling is not permitted.

Unichiller Operation Manual, Function Description; Datasheet Product Overview
Safety
Select power-failure response before unattended operation

The Pilot ONE allows the power-failure response to be set to OFF/Standby, ON, or Power Failure Auto. For exothermic processes, Process Safety mode releases maximum cooling capacity when the overtemperature trigger is reached rather than switching off all poles; the chosen behavior must match the process risk.

Unichiller Operation Manual, Normal Operation / Safety
Maintenance
Refrigerant circuit work requires certified contractors

Work on the coolant circuit must be carried out by approved refrigeration/air-conditioning system contractors. The refrigerant is R-449A (A1, H280); observe the charge and room size at installation to avoid exceeding the refrigerant limit per m³ of ambient air.

Unichiller Operation Manual, Maintenance / Installation
Electrical
Verify supply quality within ±5% voltage and ±2% frequency

Voltage tolerance is ±5% with a simultaneous frequency tolerance of ±2%, but not in the unfavorable combination. Class A, Group 1 equipment per EN 55011 may require EMC measures in residential or sensitive environments.

Unichiller 100-H Technical Datasheet, Technical Specifications

Selection & Integration Q&A

When should I choose the Unichiller 100-H instead of a smaller sibling such as the 030T or 030Tw?

Pick the 100-H when you need the larger 48 l expansion volume and 18 l minimum fill with a -20 to 100 °C range and 2 kW heating. The 030T/030Tw siblings are louder (61–69 dB(A)) and do not share this hydraulic volume; choose them only if their capacity matches your load.

What upstream electrical protection and connection hardware must I provide for this chiller?

A 460 V 3~ 60 Hz supply with 3x16 A fusing and external branch circuit protection to UL 489. The unit arrives with a cable but no plug, so you must supply and wire the plug or terminal connection; verify voltage within ±5% and frequency within ±2%.

What installation environment and clearance does the manual require?

Indoors only, 5–40 °C ambient, at least 300 lx, up to 2000 m altitude, IP20 dry location, not in an ATEX zone. Provide 50–200 cm wall clearance per side for maintenance and airflow, and set leveling feet or parking brakes before start-up.

What maintenance and consumables are not included in the base delivery?

The base unit ships without a plug and without thermal fluid; the external circuit must be filled to at least 18 l. Refrigerant circuit service must be performed by approved contractors. Shut off cooling water even for overnight downtime if a water-cooled variant is used; this air-cooled model needs no water supply.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Unichiller Operation Manual
Manual ·2,8 МБ ·82 pp.
View PDF
PDF
Unichiller 100-H Technical Datasheet
Datasheet ·85,9 КБ ·2 pp.
View PDF