Peter Huber Kältemaschinenbau Unichiller P050w-H
Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau Unichiller P050w-H

Peter Huber Kältemaschinenbau Unichiller P050w-H — Recirculating chillers with Noise level 62 dB.

The Unichiller P050w-H is a water-cooled recirculating chiller with a 5 kW cooling capacity at 20 °C and 100 °C, covering a -20 to 100 °C working range. Its 'P' designation and E2 pump suit externally closed loops with high pressure drop, distinguishing it from the T-series siblings. It serves as a central cooling source for laboratory and pilot-scale processes.

Noise level
62 dB

Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection

Model Noise level, dBPump connectionPump typeSafety classTemperature range, °CPower supply
Unichiller P050w-H Current 62G1 1/4 AG maleE2III / FL-20–100—
Unichiller 030T 69G3/4 AG maleBI / NFL-10–40460V 3~ 60Hz
Unichiller 030Tw 61G3/4 AG maleBI / NFL-20–40400V 3~ 50Hz
Unichiller 040T 69G3/4 AG maleBI / NFL-10–40400V 3~ 50Hz
Unichiller 040T-H 69G3/4 AG maleBIII / FL-10–100400V 3~ 50Hz
Unichiller 040Tw 70G3/4 AG maleBI / NFL-10–40400V 3~ 50Hz
Unichiller 040Tw-H 70G3/4 AG maleBIII / FL-10–100400V 3~ 50Hz
Unichiller 050-H 62G1 1/4 AG maleE1III / FL-20–100400V 3~ 50Hz
Unichiller 050w-H 62G1 1/4 AG maleE1III / FL-20–100460V 3~ 60Hz
Unichiller 055T —G1 1/4 AG maleC3I / NFL-20–40400V 3~ 50Hz
Unichiller 055T-H 74G1 1/4 AG maleC3III / FL-20–100400V 3~ 50Hz
Unichiller 055Tw —G1 1/4 AG maleC3I / NFL-20–40400V 3~ 50Hz
Unichiller 060T —G1 1/4 AG maleC3I / NFL-20–40400V 3~ 50Hz
Unichiller 060T-H —G1 1/4 AG maleC3III / FL-20–100400V 3~ 50Hz
Unichiller 060Tw-H —G1 1/4 AG maleC3III / FL-20–100400V 3~ 50Hz
Unichiller 070T-H 66G1 1/4 AG maleC3III / FL-10–100400V 3~ 50Hz
Unichiller 070Tw-H —G1 1/4 AG maleC3III / FL-10–100400V 3~ 50Hz
Unichiller 075w —G1 1/4 AG maleE1I / NFL-20–40400V 3~ 50Hz
Unichiller 075w-H —G1 1/4 AG maleE1III / FL-20–100400V 3~ 50Hz
Unichiller 100-H 58G1 1/4 AG maleE1III / FL-20–100460V 3~ 60Hz
Unichiller 100T —G1 1/4 AG maleC3I / NFL-20–40400V 3~ 50Hz
Unichiller 100T-H —G1 1/4 AG maleC3III / FL-20–100400V 3~ 50Hz
Unichiller 100Tw 65G1 1/4 AG maleC3I / NFL-20–40400V 3~ 50Hz
Unichiller GL 035w —G1 1/4 AG malePressure pump, speed notI / NFL-20–40460V 3~ 60Hz
Unichiller GL 050w —G1 1/4 AG malePressure pump, speed notI / NFL-20–40460V 3~ 60Hz
Unichiller GL 075 —G1 1/4 AG malePressure pump, speed notI / NFL-20–40460V 3~ 60Hz
Unichiller GL 075w —G1 1/4 AG malePressure pump, speed notI / NFL-20–40460V 3~ 60Hz
Unichiller GL 100w —G1 1/4 AG malePressure pump, speed notI / NFL-20–40400V 3~ 50Hz
Unichiller P050 62G1 1/4 AG maleE2I / NFL-20–40400V 3~ 50Hz
Unichiller P050w 62G1 1/4 AG maleE2I / NFL-20–40400V 3~ 50Hz
Unichiller P075 61G1 1/4 AG maleE2I / NFL-20–40400V 3~ 50Hz
Unichiller P075w —G1 1/4 AG maleE2I / NFL-20–40400V 3~ 50Hz
Unichiller P075w-H —G1 1/4 AG maleE2III / FL-20–100400V 3~ 50Hz
Unichiller P100 —G1 1/4 AG maleE2I / NFL-20–40460V 3~ 60Hz
Unichiller P100-H —G1 1/4 AG maleE2III / FL-20–100400V 3~ 50Hz
Unichiller P100w 58G1 1/4 AG maleE2I / NFL-20–40400V 3~ 50Hz
Unichiller P100w-H 58G1 1/4 AG maleE2III / FL-20–100400V 3~ 50Hz

Full specifications

Core Performance & Functional Specifications
Noise level 62 dB(A)
Expansion volume 48 l
Heating capacity 2 kW
Minimum fill volume 18 l
Pump connection G1 1/4 AG male
Pump speed adjustable no
Pump type E2
External sensor connection Pt100
Temperature range -20...100 °C
Dimensions, Weight & Mechanical Design
Weight 307 kg
Interfaces, Connections & Control
Controller Pilot ONE
Digital interface Ethernet, USB (Host u. Device), RS232
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C
Cooling capacity 5 kW (at 100°C)
at 20°C: 5 kW
Cooling water connection G1/2 male
Cooling water consumption 137 л/час (at 15°C, flow -20°C)
at 15°C, flow -10°C: 167 л/час · at 15°C, flow 0°C: 216 l/h
Protection rating IP20
Standards, Safety & General Data
Safety class III / FL

Description

Construction and series positioning

The P050w-H is a water-cooled, free-standing recirculating chiller in the Unichiller series. Unlike the air-cooled 030T/040T siblings (69 dB(A)), this water-cooled variant is rated at 62 dB(A) and requires a G1/2 male cooling-water connection. The 'P' in the model name marks it as particularly suitable for applications with high pressure drops, per the operation manual. The E2 pump is fixed-speed (not adjustable) and delivers up to 130 l/min at 5.7 bar maximum delivery pressure, with flow falling sharply at higher pressures. The 48 l expansion volume and 18 l minimum fill volume define the hydraulic circuit sizing.

Behavior and media

Cooling capacity is 5 kW at both 20 °C and 100 °C. The unit is designed for externally closed applications only. Cooling-water consumption depends on the required flow temperature: 216 l/h at 0 °C, 167 l/h at -10 °C, and 137 l/h at -20 °C, all at a 15 °C cooling-water intake. As cooling-water temperature rises, cooling power drops and the required flow rate may increase. The cooling-water circuit materials include copper, stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM, so only compatible water may be used. The refrigerant is R-449A (A1, H280).

Control and operation

The Pilot ONE controller provides Ethernet, USB (host and device) and RS232 interfaces, plus a Pt100 external sensor connection. Power-failure response is configurable as OFF/Standby, ON, or Power Failure Auto. In Process Safety mode, maximum cooling capacity is released when the overtemperature trigger value is reached, rather than switching off all poles. The unit is rated safety class III/FL and IP20, and is classified Class A, Group 1 for electromagnetic disturbance to EN55011.

Integration & Operating Notes

Electrical
Three-phase supply with 3x16 A fuse, no plug supplied

The chiller requires a 400 V 3~ 50 Hz supply with a 3x16 A fuse. Three-phase devices drawing less than 63 A are delivered with a cable but without a plug, so a suitable plug must be provided on site. Voltage tolerance is ±5% and frequency tolerance ±2%, but these must not be combined in opposite directions.

Datasheet, page 2, Technical Data
Cooling & Media
Cooling water: 5–20 °C intake, 0.4–6 bar differential

The cooling-water connection is G1/2 male. Minimum differential pressure is 0.4 bar and maximum pressure is 6 bar, so a pressure reducer may be needed on the building water line. Intake temperature must be between 5 °C and 20 °C; lower temperatures require insulating the cooling-water pipes. Shut off the cooling-water supply even for short downtimes such as overnight.

Datasheet, page 2, Technical Data; Operation Manual, page 28
Mounting
Indoor only, 50–200 cm wall clearance per side

The unit is IP20 and must be installed in a dry indoor location protected from water and dust, at an illuminance of at least 300 lx and up to 2000 m altitude. A wall clearance of 50 to 200 cm per side is required for maintenance. Leveling feet must be activated and parking brakes applied before start-up. Electrical lines directly below the unit must be protected against liquid ingress from condensation.

Operation Manual, pages 25, 28, 31
Process Limits
Externally closed circuits only; not for ATEX zones

The unit is designed for externally closed applications and must not be installed or started up inside an ATEX zone because it is not explosion-protected. Refrigerant charge and room size must be checked at installation to avoid exceeding the refrigerant limit per m³ of ambient air. Ambient temperature must stay between 5 °C and 40 °C.

Operation Manual, pages 13, 15, 34; Datasheet, page 2
Control & I/O
Configure power-failure response and Process Safety mode

The Pilot ONE allows the power-failure response to be set as OFF/Standby, ON, or Power Failure Auto, which determines whether the process restarts automatically after an outage. For exothermic processes, Process Safety mode releases maximum cooling capacity when the overtemperature trigger value is reached instead of switching off all poles.

Operation Manual, pages 18–19
Maintenance
Refrigerant circuit work by approved contractors only

Work on the refrigerant circuit must only be performed by approved refrigeration/air-conditioning system contractors. The cooling-water circuit materials (copper, stainless steel 1.4401, MS, PA, PPE, PTFE, EPDM) dictate compatible water quality to avoid corrosion and fouling. Maximum tightening torques for pump connections must not be exceeded and connections must be counterheld.

Operation Manual, pages 17, 28; Datasheet, page 2

Selection & Integration Q&A

When should I choose the P050w-H over the 030T or 040T siblings?

Choose the P050w-H for high-pressure-drop loops (the 'P' designation) or where water cooling and lower noise (62 dB(A) vs 69 dB(A)) are needed. The 030T/040T are air-cooled alternatives; select them only if a cooling-water supply is unavailable.

What cooling-water supply and connection parts must be provided on site?

A G1/2 male connection with 5–20 °C intake, 0.4–6 bar differential pressure, and a pressure reducer if line pressure exceeds 6 bar. Insulate pipes if intake is below 5 °C. The unit is water-cooled and requires this supply for operation.

What are the installation environment and duty-cycle restrictions?

Indoor use only, IP20, ambient 5–40 °C, illuminance ≥300 lx, altitude ≤2000 m, and 50–200 cm wall clearance per side. Not for ATEX zones. Shut off cooling water even for overnight downtime. Leveling feet and parking brakes must be set before start-up.

What maintenance and accessories are required beyond the base delivery?

A suitable three-phase plug must be procured (cable supplied, plug not). Refrigerant circuit service only by approved contractors. No consumables or cables are listed as included beyond the power cable. Cooling-water circuit compatibility with copper, stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM must be verified.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Unichiller P050w-H Recirculating Chiller Datasheet
Datasheet ·92,3 КБ ·2 pp.
View PDF
PDF
Unichiller Operation Manual
Manual ·2,8 МБ ·82 pp.
View PDF