Peter Huber Kältemaschinenbau Unichiller P100-H
Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau Unichiller P100-H

Peter Huber Kältemaschinenbau Unichiller P100-H — Recirculating chillers.

The Unichiller P100-H is a recirculating chiller with a high-discharge-pressure E2 pump, built for externally closed circuits with high pressure drop. Its -20...100 °C range and 2 kW heating distinguish it from standard-pump siblings. It serves as a closed-loop cooling source for industrial processes requiring stable temperature control.

Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection

Model Noise level, dBPump connectionPump typeSafety classTemperature range, °CPower supply
Unichiller P100-H Current —G1 1/4 AG maleE2III / FL-20–100400V 3~ 50Hz
Unichiller 030T 69G3/4 AG maleBI / NFL-10–40460V 3~ 60Hz
Unichiller 030Tw 61G3/4 AG maleBI / NFL-20–40400V 3~ 50Hz
Unichiller 040T 69G3/4 AG maleBI / NFL-10–40400V 3~ 50Hz
Unichiller 040T-H 69G3/4 AG maleBIII / FL-10–100400V 3~ 50Hz
Unichiller 040Tw 70G3/4 AG maleBI / NFL-10–40400V 3~ 50Hz
Unichiller 040Tw-H 70G3/4 AG maleBIII / FL-10–100400V 3~ 50Hz
Unichiller 050-H 62G1 1/4 AG maleE1III / FL-20–100400V 3~ 50Hz
Unichiller 050w-H 62G1 1/4 AG maleE1III / FL-20–100460V 3~ 60Hz
Unichiller 055T —G1 1/4 AG maleC3I / NFL-20–40400V 3~ 50Hz
Unichiller 055T-H 74G1 1/4 AG maleC3III / FL-20–100400V 3~ 50Hz
Unichiller 055Tw —G1 1/4 AG maleC3I / NFL-20–40400V 3~ 50Hz
Unichiller 060T —G1 1/4 AG maleC3I / NFL-20–40400V 3~ 50Hz
Unichiller 060T-H —G1 1/4 AG maleC3III / FL-20–100400V 3~ 50Hz
Unichiller 060Tw-H —G1 1/4 AG maleC3III / FL-20–100400V 3~ 50Hz
Unichiller 070T-H 66G1 1/4 AG maleC3III / FL-10–100400V 3~ 50Hz
Unichiller 070Tw-H —G1 1/4 AG maleC3III / FL-10–100400V 3~ 50Hz
Unichiller 075w —G1 1/4 AG maleE1I / NFL-20–40400V 3~ 50Hz
Unichiller 075w-H —G1 1/4 AG maleE1III / FL-20–100400V 3~ 50Hz
Unichiller 100-H 58G1 1/4 AG maleE1III / FL-20–100460V 3~ 60Hz
Unichiller 100T —G1 1/4 AG maleC3I / NFL-20–40400V 3~ 50Hz
Unichiller 100T-H —G1 1/4 AG maleC3III / FL-20–100400V 3~ 50Hz
Unichiller 100Tw 65G1 1/4 AG maleC3I / NFL-20–40400V 3~ 50Hz
Unichiller GL 035w —G1 1/4 AG malePressure pump, speed notI / NFL-20–40460V 3~ 60Hz
Unichiller GL 050w —G1 1/4 AG malePressure pump, speed notI / NFL-20–40460V 3~ 60Hz
Unichiller GL 075 —G1 1/4 AG malePressure pump, speed notI / NFL-20–40460V 3~ 60Hz
Unichiller GL 075w —G1 1/4 AG malePressure pump, speed notI / NFL-20–40460V 3~ 60Hz
Unichiller GL 100w —G1 1/4 AG malePressure pump, speed notI / NFL-20–40400V 3~ 50Hz
Unichiller P050 62G1 1/4 AG maleE2I / NFL-20–40400V 3~ 50Hz
Unichiller P050w 62G1 1/4 AG maleE2I / NFL-20–40400V 3~ 50Hz
Unichiller P050w-H 62G1 1/4 AG maleE2III / FL-20–100—
Unichiller P075 61G1 1/4 AG maleE2I / NFL-20–40400V 3~ 50Hz
Unichiller P075w —G1 1/4 AG maleE2I / NFL-20–40400V 3~ 50Hz
Unichiller P075w-H —G1 1/4 AG maleE2III / FL-20–100400V 3~ 50Hz
Unichiller P100 —G1 1/4 AG maleE2I / NFL-20–40460V 3~ 60Hz
Unichiller P100w 58G1 1/4 AG maleE2I / NFL-20–40400V 3~ 50Hz
Unichiller P100w-H 58G1 1/4 AG maleE2III / FL-20–100400V 3~ 50Hz

Full specifications

Core Performance & Functional Specifications
Expansion volume 48 l
Heating capacity 2 kW
Minimum fill volume 18 l
Pump connection G1 1/4 AG male
Pump speed adjustable no
Pump type E2
External sensor connection Pt100
Temperature range -20...100 °C
Dimensions, Weight & Mechanical Design
Weight 299 kg
Electrical, Power & Drive Specifications
Current consumption 15 A (max)
Power supply 400V 3~ 50Hz
Interfaces, Connections & Control
Controller Pilot ONE
Digital interface Ethernet, USB (Host u. Device), RS232
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C
Protection rating IP20
Standards, Safety & General Data
Safety class III / FL

Description

Construction and series positioning

Operating behavior

Installation and operation

Integration & Operating Notes

Process Limits
External circuit must be closed and pressure-rated

The chiller is designed exclusively for externally closed applications; an open or vented external circuit will not work and may cause fluid loss or poor temperature control. Ensure the external loop is sealed and compatible with the pump's high discharge pressure.

Unichiller Operation Manual, Section Function Description
Electrical
Supply must be 400 V 3-phase with 3x16 A fusing

The unit draws up to 15 A per phase and requires a 400 V 3~ 50 Hz supply with 3x16 A fusing. It is delivered with a cable but without a plug, so the installer must provide a suitable 3-phase plug and ensure the site supply meets the linked voltage/frequency tolerance rules.

Unichiller P100-H Technical Datasheet, Technical Specifications
Mounting
Maintain 50–200 cm side clearance for service access

Free-standing installation requires a wall clearance of 50 to 200 cm on either side for maintenance. The unit must be placed indoors with illuminance at least 300 lx and at altitudes up to 2000 m. Leveling feet or parking brakes must be engaged before operation to prevent movement.

Unichiller Operation Manual, Section Commissioning
Control & I/O
Configure power-failure response to match process risk

The Pilot ONE controller allows the power-failure response to be set to OFF/Standby, ON, or Power Failure Auto. For exothermic processes, Process Safety mode releases maximum cooling capacity when the overtemperature trigger is reached, instead of switching off all poles. Choose the mode that matches the process hazard analysis.

Unichiller Operation Manual, Section Normal Operation
Maintenance
Refrigerant circuit work requires certified contractors

Any work on the refrigerant circuit must be performed only by approved refrigeration/air-conditioning system contractors. The unit contains 1.1 kg of R-449A (GWP 1397, 1.5 t CO2 equivalent), so refrigerant handling and leak-check obligations apply. The expansion tank has a digital level indicator for routine monitoring.

Unichiller Operation Manual, Section Maintenance
Cooling & Media
Cooling capacity derates above 20 °C ambient

Published cooling capacity is valid at 20 °C room temperature; higher ambient temperatures reduce available cooling. Size the chiller with margin if the installation room cannot be held near 20 °C. Also shut off cooling water supply (if water-cooled) during downtimes to prevent condensate damage.

Unichiller P100-H Technical Datasheet, Product Overview

Selection & Integration Q&A

When should I choose the P100-H over a standard Unichiller like the 030T or 040T?

Choose the P100-H when your external circuit has high pressure drop that would stall a standard pump; its 'P' pump delivers higher discharge pressure. For low-pressure-drop loops or lower noise needs, the 030T/040T series may suffice, but verify cooling capacity and temperature range for your duty.

What are the electrical supply and protection requirements for integrating this chiller?

It requires 400 V 3~ 50 Hz, max 15 A per phase, with 3x16 A fusing. The unit comes with a cable but no plug, so you must provide a suitable 3-phase plug. Ensure voltage and frequency tolerances are met: ±5 % voltage only with ±2 % frequency; -5 % voltage with +2 % frequency is not allowed.

What installation environment and clearance are mandatory for the P100-H?

Install indoors only, at 5...40 °C ambient, illuminance ≥300 lx, altitude ≤2000 m, and not in an ATEX zone. Provide 50–200 cm wall clearance per side for maintenance. Engage leveling feet or parking brakes before start-up. IP20 requires a dry, protected location.

What maintenance and service items are required, and what is not included in the base delivery?

Refrigerant circuit work must be by certified contractors; monitor fluid level via the digital indicator. The base delivery includes a cable but no plug, and no external hoses or fittings are mentioned. Regular checks of the expansion tank level and cooling water shutoff during downtimes are necessary.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Unichiller P100-H Technical Datasheet
Datasheet ·85,9 КБ ·2 pp.
View PDF
PDF
Unichiller Operation Manual
Manual ·2,8 МБ ·82 pp.
View PDF