Peter Huber Kältemaschinenbau Unichiller P100w
Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau Unichiller P100w

Peter Huber Kältemaschinenbau Unichiller P100w — Recirculating chillers with Noise level 58 dB.

The Unichiller P100w is a water-cooled recirculating chiller with a 400 V three-phase supply, rated for -20 to 40 °C and built for externally closed circuits. Its 'P' designation targets high-pressure-drop applications, delivering up to 130 l/min at 5.7 bar. It serves as a central cooling source for laboratory or process loops requiring stable temperature control.

Noise level
58 dB

Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection

Model Noise level, dBPump connectionPump typeSafety classTemperature range, °CPower supply
Unichiller P100w Current 58G1 1/4 AG maleE2I / NFL-20–40400V 3~ 50Hz
Unichiller 030T 69G3/4 AG maleBI / NFL-10–40460V 3~ 60Hz
Unichiller 030Tw 61G3/4 AG maleBI / NFL-20–40400V 3~ 50Hz
Unichiller 040T 69G3/4 AG maleBI / NFL-10–40400V 3~ 50Hz
Unichiller 040T-H 69G3/4 AG maleBIII / FL-10–100400V 3~ 50Hz
Unichiller 040Tw 70G3/4 AG maleBI / NFL-10–40400V 3~ 50Hz
Unichiller 040Tw-H 70G3/4 AG maleBIII / FL-10–100400V 3~ 50Hz
Unichiller 050-H 62G1 1/4 AG maleE1III / FL-20–100400V 3~ 50Hz
Unichiller 050w-H 62G1 1/4 AG maleE1III / FL-20–100460V 3~ 60Hz
Unichiller 055T —G1 1/4 AG maleC3I / NFL-20–40400V 3~ 50Hz
Unichiller 055T-H 74G1 1/4 AG maleC3III / FL-20–100400V 3~ 50Hz
Unichiller 055Tw —G1 1/4 AG maleC3I / NFL-20–40400V 3~ 50Hz
Unichiller 060T —G1 1/4 AG maleC3I / NFL-20–40400V 3~ 50Hz
Unichiller 060T-H —G1 1/4 AG maleC3III / FL-20–100400V 3~ 50Hz
Unichiller 060Tw-H —G1 1/4 AG maleC3III / FL-20–100400V 3~ 50Hz
Unichiller 070T-H 66G1 1/4 AG maleC3III / FL-10–100400V 3~ 50Hz
Unichiller 070Tw-H —G1 1/4 AG maleC3III / FL-10–100400V 3~ 50Hz
Unichiller 075w —G1 1/4 AG maleE1I / NFL-20–40400V 3~ 50Hz
Unichiller 075w-H —G1 1/4 AG maleE1III / FL-20–100400V 3~ 50Hz
Unichiller 100-H 58G1 1/4 AG maleE1III / FL-20–100460V 3~ 60Hz
Unichiller 100T —G1 1/4 AG maleC3I / NFL-20–40400V 3~ 50Hz
Unichiller 100T-H —G1 1/4 AG maleC3III / FL-20–100400V 3~ 50Hz
Unichiller 100Tw 65G1 1/4 AG maleC3I / NFL-20–40400V 3~ 50Hz
Unichiller GL 035w —G1 1/4 AG malePressure pump, speed notI / NFL-20–40460V 3~ 60Hz
Unichiller GL 050w —G1 1/4 AG malePressure pump, speed notI / NFL-20–40460V 3~ 60Hz
Unichiller GL 075 —G1 1/4 AG malePressure pump, speed notI / NFL-20–40460V 3~ 60Hz
Unichiller GL 075w —G1 1/4 AG malePressure pump, speed notI / NFL-20–40460V 3~ 60Hz
Unichiller GL 100w —G1 1/4 AG malePressure pump, speed notI / NFL-20–40400V 3~ 50Hz
Unichiller P050 62G1 1/4 AG maleE2I / NFL-20–40400V 3~ 50Hz
Unichiller P050w 62G1 1/4 AG maleE2I / NFL-20–40400V 3~ 50Hz
Unichiller P050w-H 62G1 1/4 AG maleE2III / FL-20–100—
Unichiller P075 61G1 1/4 AG maleE2I / NFL-20–40400V 3~ 50Hz
Unichiller P075w —G1 1/4 AG maleE2I / NFL-20–40400V 3~ 50Hz
Unichiller P075w-H —G1 1/4 AG maleE2III / FL-20–100400V 3~ 50Hz
Unichiller P100 —G1 1/4 AG maleE2I / NFL-20–40460V 3~ 60Hz
Unichiller P100-H —G1 1/4 AG maleE2III / FL-20–100400V 3~ 50Hz
Unichiller P100w-H 58G1 1/4 AG maleE2III / FL-20–100400V 3~ 50Hz

Full specifications

Core Performance & Functional Specifications
Noise level 58 dB(A)
Expansion volume 48 l
Minimum fill volume 18 l
Pump connection G1 1/4 AG male
Pump speed adjustable no
Pump type E2
External sensor connection Pt100
Temperature range -20...40 °C
Dimensions, Weight & Mechanical Design
Weight 311 kg
Electrical, Power & Drive Specifications
Current consumption 13 A (max.)
Power supply 400V 3~ 50Hz
Interfaces, Connections & Control
Controller Pilot ONE
Digital interface Ethernet, USB (Host u. Device), RS232
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C
Cooling water connection G1/2 male
Cooling water consumption 240 л/час (at 15°C, flow -20°C)
at 15°C, flow -10°C: 270 л/час · at 15°C, flow 0°C: 330 l/h
Cooling Water Pressure 6 bar (max.)
Protection rating IP20
Standards, Safety & General Data
Safety class I / NFL

Description

Construction and Series Positioning

The Unichiller P100w is a water-cooled, three-phase recirculating chiller in the Unichiller series. Unlike air-cooled siblings such as the Unichiller 030T (69 dB(A)) and 030Tw (61 dB(A)), this model uses a cooling water circuit with G1/2 male connections and consumes 330 l/h at 15 °C water inlet and 0 °C flow. The 'P' in the model name indicates suitability for applications with high pressure drops, per the operation manual. The unit weighs 311 kg and has IP20 protection, an atmospheric open expansion tank (48 l), and a minimum fill volume of 18 l.

Behavior Under Load and Media

Cooling capacity is rated at 20 °C room temperature, 15 °C cooling water inlet, and 0.5 bar differential pressure. Cooling water consumption rises as flow temperature decreases: 330 l/h at 0 °C, 270 l/h at -10 °C, and 240 l/h at -20 °C. The pump delivers up to 130 l/min at 5.7 bar, but flow falls sharply at high pressure (e.g., 20 l/min at 5.5 bar), so external circuit pressure drop must be checked. The unit is intended only for externally closed applications; the expansion tank is open to atmosphere. The cooling water circuit contains copper, stainless steel 1.4401, MS, PA, PPE, PTFE, and EPDM, restricting water quality.

Installation, Control, and Operation

The Pilot ONE controller provides Ethernet, USB (host and device), and RS232 interfaces, plus a Pt100 external sensor connection. Power-failure response is configurable (OFF/Standby, ON, or Power Failure Auto). Process Safety mode releases maximum cooling capacity when the overtemperature trigger is reached, rather than switching off all poles. The unit requires 400 V 3~ 50 Hz supply with a 3x16 A fuse; three-phase devices under 63 A are delivered with cable but without plug. Cooling water pressure must be between 0.5 and 6 bar, and inlet temperature between 5 and 20 °C. Installation requires 50–200 cm wall clearance per side, indoor use only, and protection of electrical lines below the unit against condensate.

Integration & Operating Notes

Electrical
Supply must be 400 V 3~ with 3x16 A fusing

The unit draws up to 13 A per phase and requires a 3x16 A fuse. Voltage tolerance is ±5% with simultaneous frequency tolerance of ±2%; opposite-sign deviations are not permitted. The customer must provide a mating plug because the unit ships with cable only.

Unichiller P100w Datasheet, Technical Specifications
Cooling & Media
Cooling water inlet must stay between 5 and 20 °C

The chiller is designed for cooling water intake between 5 °C and 20 °C. Higher inlet temperatures reduce capacity, and published performance assumes 15 °C inlet and 0.5 bar differential pressure. Pipes must be insulated where condensation can occur.

Unichiller P100w Datasheet, Technical Specifications
Process Limits
External circuit must be closed and pressure drop checked

The unit is intended only for externally closed applications; the expansion tank is open to atmosphere. The pump delivers 130 l/min at 5.7 bar but only 20 l/min at 5.5 bar, so the external loop's pressure drop must be matched to avoid insufficient flow.

Unichiller Operation Manual, Function Description; Unichiller P100w Datasheet
Mounting
Maintain 50–200 cm wall clearance per side

Free-standing models require 50 to 200 cm clearance on either side for maintenance access. The unit must be installed indoors at illuminance of at least 300 lx and up to 2000 m altitude. Leveling feet or parking brakes must be engaged before startup.

Unichiller Operation Manual, Setup Mode
Maintenance
Refrigerant work only by certified contractors

The refrigerant circuit contains R-449A (1.03 kg, 1.4 t CO2 equivalent) and may only be serviced by approved refrigeration/air-conditioning contractors. Cooling water supply must be shut off even for short downtimes such as overnight to prevent water damage.

Unichiller Operation Manual, Maintenance; Unichiller P100w Datasheet
Control & I/O
Configure power-failure response for process safety

The Pilot ONE allows power-failure response OFF/Standby, ON, or Power Failure Auto. For exothermic processes, Process Safety mode releases maximum cooling when the overtemperature trigger is reached instead of switching off all poles, preventing runaway temperatures.

Unichiller Operation Manual, Normal Operation

Selection & Integration Q&A

When should I choose the Unichiller P100w over the air-cooled Unichiller 030T or 030Tw?

Choose the P100w for high-pressure-drop applications (P designation) and where a water-cooled circuit is available; it requires 330 l/h cooling water at 0 °C flow. Air-cooled 030T/030Tw suit sites without cooling water but have higher noise (69/61 dB(A)).

What are the requirements for the cooling water supply and the external process loop?

Cooling water: 5–20 °C inlet, 0.5–6 bar differential pressure, G1/2 male connections, and materials compatible with copper, stainless steel 1.4401, MS, PA, PPE, PTFE, EPDM. External loop must be closed, with pressure drop checked against the pump curve (130 l/min at 5.7 bar; 20 l/min at 5.5 bar).

What installation and duty-cycle limits apply from the manual?

Indoors only, 5–40 °C ambient, IP20, 50–200 cm wall clearance per side, illuminance ≥300 lx, altitude ≤2000 m. Not for ATEX zones. Shut off cooling water even overnight. Leveling feet/parking brakes must be engaged before operation.

What maintenance is required and what is not included in the base delivery?

Refrigerant circuit work only by certified contractors; R-449A charge 1.03 kg (1.4 t CO2e). The unit ships with cable but without a plug for three-phase <63 A. No external Pt100 sensor or process hoses are included; these must be sourced separately.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Unichiller P100w Datasheet
Datasheet ·92,3 КБ ·2 pp.
View PDF
PDF
Unichiller Operation Manual
Manual ·2,8 МБ ·82 pp.
View PDF