Peter Huber Kältemaschinenbau Unistat 520w Dynamisches
Peter Huber Kältemaschinenbau Unistat 520w Dynamisches — Temperature control units with Noise level 61 dB.
Water-cooled (w) free-standing Unistat 520w with magnetically coupled stainless-steel pump, covering -55 to 250 °C with 6 kW heating and 400 V three-phase supply. It sits between the 515w and 525w in the series, distinguished by water cooling and dynamic performance. Used for externally closed or open temperature control of reactors and process equipment.
Peter Huber Kältemaschinenbau Unistat Series — Model Comparison & Selection
| Model | Noise level, dB | Display resolution | Heating capacity, W | Pump connection | Pump type | Temperature range, °C |
|---|---|---|---|---|---|---|
| Unistat 520w Dynamisches Current | 61 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 510w Dynamisches | 60 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat 515w Dynamisches | — | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat 525 Dynamisches | 56 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 525w Dynamisches | 61 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 527w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 530w Dynamisches | 59 | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 540w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 545w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 610w Dynamisches | 62 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 615w Dynamisches | 62 | 0, 01 | 12000 | M30x1, 5 AG male | Pressure pump, variable | -60–200 |
| Unistat 620w Dynamisches | 68 | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 625w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 630w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 635w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 640w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 645w Dynamisches | — | 0, 01 | 36000 | flange DN32 PN10/40 EN10 | magnetically coupled, st | -60–200 |
| Unistat 650w Dynamisches | 73 | 0, 01 | 48000 | flange DN32 PN10/40 EN10 | magnetically coupled, st | -60–200 |
| Unistat 680w Dynamisches | — | 0, 01 | 96000 | DN50 PN16 (DIN EN 1092-1 | magnetically coupled, st | -60–200 |
| Unistat GL 530w Dynamisches | 61 | 0, 01 | 6000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 535w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 540w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 550w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 560w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 570w Dynamisches | — | 0, 01 | 48000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P530w Dynamisches | 61 | 0, 01 | 6000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P535w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P540w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P550w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P560w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P570w Dynamisches | — | 0, 01 | 48000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat P510 Dynamisches | 60 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat P510w Dynamisches | 60 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat P515w Dynamisches | — | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat P520 Dynamisches | — | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P520w Dynamisches | 61 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P525 Dynamisches | 56 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P525w Dynamisches | 61 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P527w Dynamisches | 57 | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P530w Dynamisches | 62 | 0.01 | 12000 | M38x1,5 AG male | magnetically coupled, st | -55–250 |
| Unistat P540w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P545w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P610 Dynamisches | — | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P610w Dynamisches | 62 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P615 Dynamisches | — | 0, 01 | 12000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P615w Dynamisches | 62 | 0, 01 | 12000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P620w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P625w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P630w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P635w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P645w Dynamisches | — | 0, 01 | 36000 | flange DN32 PN10/40 EN10 | magnetically coupled, st | -60–200 |
| Unistat P650w Dynamisches | — | 0, 01 | 48000 | flange DN32 PN10/40 EN10 | magnetically coupled, st | -60–200 |
Full specifications
| Noise level | 61 dB(A) |
| Control output | POKO ONE |
| Expansion volume | 16 l |
| Heating capacity | 6 kW |
| Pump connection | M30x1, 5 AG male |
| Pump speed adjustable | Yes |
| Pump type | magnetically coupled, stainless steel |
| External sensor connection | Pt100 |
| Temperature range | -55...250 °C |
| Weight | 210 kg |
| Current consumption | 14 A |
| Power supply | 400V 3~ 50Hz |
| Controller | Pilot ONE |
| Display resolution | 0, 01 K |
| Digital interface | Ethernet, USB (Host u. Device), RS232 |
| Maximum viscosity | 50 mm²/s |
| Ambient temperature limit | 5...40 °C |
| Cooling water connection | G1/2 male |
| Cooling water consumption | 492 l/h (at 15°C, flow 0°C) |
| Cooling water differential pressure | 1 bar |
| Cooling Water Pressure | 6 bar |
| Protection rating | IP20 |
| Safety class | III / FL |
Description
Construction and series positioning
- The Unistat 520w Dynamisches is the water-cooled ('w') variant of the 520 dynamic series; siblings include the 510w, 515w, 525 and 525w. The 'w' suffix denotes water cooling, so the unit rejects heat to a cooling-water circuit rather than to room air.
- The circulation pump is magnetically coupled and stainless steel, with adjustable speed; pump connection is M30x1.5 male. The controller is Pilot ONE with POKO ONE control output, Ethernet, USB (host and device) and RS232 interfaces, and a Pt100 external sensor input.
- Safety class III / FL per DIN 12876; the unit is rated for external closed and external open applications, the latter requiring an isolation sleeve accessory.
Behavior under load and media
- Temperature range is -55 to 250 °C with 6 kW heating capacity. Cooling capacity is strongly temperature-dependent: the datasheet states 6 kW at 0 °C falling to 0.65 kW at -50 °C with ethanol, so low-temperature duty must be checked against actual process heat load.
- The pump delivers up to 79 l/min maximum and 43 l/min at 1.0 bar, with maximum delivery pressure 1.5 bar; external circuit pressure drop must be checked against this curve.
- Cooling water consumption is 492 l/h at 15 °C with flow at 0 °C; cooling water inlet must be 5–20 °C and pipes insulated if below dew point. The cooling-water circuit materials include copper, stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM, so only compatible water may be used.
Installation, connection and control
- Power supply is 400 V 3~ 50 Hz, max current 14 A, fuse 3x16 A. Three-phase devices below 63 A are supplied with cable but without a plug, so a suitable plug must be provided on site. Leakage current exceeds 3.5 mA, so earthing and RCD selection must account for this.
- Cooling water connections are G1/2 male; minimum differential pressure 1 bar, maximum pressure 6 bar. Pump connection M30x1.5 male requires DIN 3863 ball socket and DIN 3870 sleeve nut hoses.
- Ambient temperature 5–40 °C; protection rating IP20; noise 61 dB(A); weight 210 kg. The unit emits EN55011 Class A, Group 1 disturbances, which may require EMC measures in sensitive environments.
- The Pilot ONE controller supports overtemperature protection settings, Delta T limiter, Pt100 monitoring, auto/expert mode, freeze protection and setpoint thresholds; filling, venting, degassing and draining procedures differ for externally closed versus open applications.
Integration & Operating Notes
The datasheet explicitly warns that leakage current exceeds 3.5 mA, so protective earthing must be reliable and residual current protective devices must be selected with this leakage in mind; a standard 30 mA RCD may not be appropriate without engineering review.
The operation manual states the temperature control unit must not be installed or started within an ATEX zone; explosion protection requires an Ex px cabinet with a separate ATEX annex, and only the model/serial number on the Ex px cabinet rating plate is suitable. Site selection must exclude hazardous areas.
The manual requires upright transport and storage only; horizontal transport damages the compressor. Only an emptied unit may be moved. When moving between cold and warm environments, allow about 2 hours acclimation before switching on to prevent condensation-induced electrical faults. Casters are not for transport and carry only 25% of total mass symmetrically.
In Process Safety mode, when the overtemperature trigger value is reached the controller releases maximum cooling capacity instead of switching off all poles. This mode requires the compressor to be set to Permanently ON in the controller configuration; otherwise the safety function will not deliver cooling under exothermic conditions.
The manual directs that the cooling water supply be shut off even for shorter downtimes such as overnight, to prevent water damage and unnecessary load on the cooling water circuit. Hoses and connections must be periodically checked for leaks and quality and replaced as needed.
Selection & Integration Q&A
The 520w is the water-cooled dynamic unit between the 515w and 525w in capacity. Choose it when the process heat load and -55 to 250 °C range fit its 6 kW heating and cooling curve, and when water cooling is available; the 525w offers higher capacity, the 515w lower. The 525 (non-w) is air-cooled and avoids a cooling-water circuit entirely.
Provide G1/2 male connections with 5–20 °C water at 1–6 bar differential pressure and 492 l/h at 15 °C/0 °C flow. Insulate pipes if below dew point. The circuit contains copper, stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM, so only compatible water may be used.
Ambient 5–40 °C, IP20, upright transport only, 2 h acclimation after temperature change, no ATEX zone. Leveling feet or parking brakes must be set before operation. The unit emits EN55011 Class A Group 1 disturbances, so EMC measures may be needed near sensitive equipment.
The base unit ships with cable but no plug for the 400 V three-phase supply; a suitable plug must be provided on site. Open applications need an isolation sleeve accessory. Periodic checks of hoses and connections, cooling-water shutoff for overnight downtime, and refrigerant work by approved contractors are required; no consumables are included.