No photo available yet
Peter Huber Kältemaschinenbau Unistat P610w Dynamisches
Peter Huber Kältemaschinenbau Unistat P610w Dynamisches — Temperature control units with Noise level 62 dB.
The Unistat P610w Dynamisches is a water-cooled, free-standing temperature control unit with a magnetically coupled stainless-steel pump and Pilot ONE controller, covering -60 to 200 °C. Its water-cooled refrigeration machine requires 400 l/h cooling water at 15 °C and delivers 2.6 kW at -40 °C but only 0.05 kW at -60 °C, so the low limit suits very small loads. It serves closed-loop process temperature control in industrial environments.
Peter Huber Kältemaschinenbau Unistat Series — Model Comparison & Selection
| Model | Noise level, dB | Display resolution | Heating capacity, W | Pump connection | Pump type | Temperature range, °C |
|---|---|---|---|---|---|---|
| Unistat P610w Dynamisches Current | 62 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 510w Dynamisches | 60 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat 515w Dynamisches | — | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat 520w Dynamisches | 61 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 525 Dynamisches | 56 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 525w Dynamisches | 61 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 527w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 530w Dynamisches | 59 | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 540w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 545w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat 610w Dynamisches | 62 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 615w Dynamisches | 62 | 0, 01 | 12000 | M30x1, 5 AG male | Pressure pump, variable | -60–200 |
| Unistat 620w Dynamisches | 68 | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 625w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 630w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 635w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 640w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat 645w Dynamisches | — | 0, 01 | 36000 | flange DN32 PN10/40 EN10 | magnetically coupled, st | -60–200 |
| Unistat 650w Dynamisches | 73 | 0, 01 | 48000 | flange DN32 PN10/40 EN10 | magnetically coupled, st | -60–200 |
| Unistat 680w Dynamisches | — | 0, 01 | 96000 | DN50 PN16 (DIN EN 1092-1 | magnetically coupled, st | -60–200 |
| Unistat GL 530w Dynamisches | 61 | 0, 01 | 6000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 535w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 540w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 550w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 560w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL 570w Dynamisches | — | 0, 01 | 48000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P530w Dynamisches | 61 | 0, 01 | 6000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P535w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P540w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P550w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P560w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat GL P570w Dynamisches | — | 0, 01 | 48000 | M38x1, 5 AG male | magnetically coupled, st | -50–200 |
| Unistat P510 Dynamisches | 60 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat P510w Dynamisches | 60 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat P515w Dynamisches | — | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -50–250 |
| Unistat P520 Dynamisches | — | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P520w Dynamisches | 61 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P525 Dynamisches | 56 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P525w Dynamisches | 61 | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P527w Dynamisches | 57 | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P530w Dynamisches | 62 | 0.01 | 12000 | M38x1,5 AG male | magnetically coupled, st | -55–250 |
| Unistat P540w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P545w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -55–250 |
| Unistat P610 Dynamisches | — | 0, 01 | 6000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P615 Dynamisches | — | 0, 01 | 12000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P615w Dynamisches | 62 | 0, 01 | 12000 | M30x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P620w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P625w Dynamisches | — | 0, 01 | 12000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P630w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P635w Dynamisches | — | 0, 01 | 24000 | M38x1, 5 AG male | magnetically coupled, st | -60–200 |
| Unistat P645w Dynamisches | — | 0, 01 | 36000 | flange DN32 PN10/40 EN10 | magnetically coupled, st | -60–200 |
| Unistat P650w Dynamisches | — | 0, 01 | 48000 | flange DN32 PN10/40 EN10 | magnetically coupled, st | -60–200 |
Full specifications
| Noise level | 62 dB(A) (sound pressure level) |
| Control output | POKO ONE (potential-free contact) |
| Expansion volume | 26 l |
| Heating capacity | 6 kW |
| Pump connection | M30x1, 5 AG male |
| Pump speed adjustable | Yes |
| Pump type | magnetically coupled, stainless steel |
| External sensor connection | Pt100 |
| Temperature range | -60...200 °C |
| Weight | 358 kg (net) |
| Current consumption | 16 A (max) |
| Power supply | 400V 3~ 50Hz |
| Controller | Pilot ONE |
| Display resolution | 0, 01 K |
| Digital interface | Ethernet, USB (Host u. Device), RS232 |
| Maximum viscosity | 50 mm²/s (max) |
| Ambient temperature limit | 5...40 °C (permissible) |
| Cooling water connection | G1/2 male |
| Cooling water consumption | 400 l/h (at 15°C, flow 0°C) |
| Cooling water differential pressure | 1 bar (min) |
| Cooling Water Pressure | 6 bar (max) |
| Protection rating | IP20 |
| Safety class | III / FL |
Description
Construction and series positioning
- Free-standing water-cooled unit (suffix 'w') with dimensions 630x704x1520 mm and 358 kg net weight; IP20, ambient 5–40 °C.
- Magnetically coupled stainless-steel pump, speed-adjustable, with M30x1.5 male pump connection and G1/2 male cooling-water connection.
- Pilot ONE controller with POKO ONE potential-free contact; interfaces Ethernet, USB host/device, RS232; external Pt100 sensor input.
- Within the Unistat w-series, the P610w is the high-capacity water-cooled variant; siblings 510w/515w/520w/525 Dynamisches are lower-capacity or air-cooled alternatives.
Thermal behavior under load
- Temperature range -60…200 °C with 6 kW heating capacity and 26 l expansion volume.
- Cooling capacity falls steeply at low temperature: 2.6 kW at -40 °C versus 0.05 kW at -60 °C, so the -60 °C endpoint is only usable with very small heat loads.
- Pump delivers up to 82 l/min and 3 bar maximum pressure; at 2.5 bar the flow is 36 l/min, so the external circuit pressure drop must be checked against the pump curve.
- Maximum viscosity 50 mm²/s; display resolution 0.01 K.
Installation, connection and control
- Requires 400 V 3~ 50 Hz supply, 16 A maximum current, 3x20 A fusing; three-phase devices below 63 A are supplied with cable but without plug.
- Leakage current exceeds 3.5 mA, so protective earth and a suitable RCD are mandatory.
- Cooling water must be 5–20 °C, minimum 1 bar differential pressure, maximum 6 bar; consumption 400 l/h at 15 °C water and 0 °C flow.
- Cooling-water circuit materials include copper, stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM; only compatible water may be used.
- EMC class A, group 1 (EN55011), intended for industrial environments; voltage tolerance ±5% only with simultaneous frequency tolerance ±2%, and combinations such as -5% voltage with +2% frequency are not allowed.
- Refrigerant R-452A, GWP 2141, CO2 equivalent 5.5 t; F-gas obligations apply.
Operation and safety
- Safety class III / FL; for FL-rated flammable heat transfer fluid, fire point must be ≥65 °C and ethanol use requires supervised operation.
- Process Safety mode releases maximum cooling at the overtemperature trigger instead of switching off all poles; requires compressor set to Permanently ON.
- Power Failure Auto can resume temperature control automatically after a power outage if it was active.
- Unit must not be installed in an ATEX zone; medical-device and direct-food applications are not permissible.
Integration & Operating Notes
The unit must be transported and stored upright; horizontal transport damages the compressor. Only an emptied unit may be moved. When moving between cold and warm environments, allow about 2 hours acclimation before switching on to prevent condensation-induced electrical faults. Leveling feet must be activated and parking brakes engaged before commissioning.
In Process Safety mode the controller releases maximum cooling capacity at the overtemperature trigger instead of switching off all poles. This mode requires the compressor to be set to Permanently ON; otherwise the protective function is not effective. Power Failure Auto can resume temperature control automatically after a power outage if it was active, which must be assessed for unattended operation.
Selection & Integration Q&A
Choose the P610w when you need the higher cooling capacity of the water-cooled P-series at low temperatures and have a suitable cooling-water supply (400 l/h at 15 °C). The 510w/515w/520w are lower-capacity water-cooled variants; the 525 Dynamisches is air-cooled and needs no cooling water but has different capacity and noise data.
Provide cooling water at 5–20 °C, minimum 1 bar differential pressure, maximum 6 bar, and 400 l/h at 15 °C water with 0 °C flow. The connection is G1/2 male. The circuit contains copper, stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM, so use compatible water and insulate pipes where condensation can occur.
The base delivery includes a cable but no plug for the 400 V three-phase connection; the customer must provide the final connection and RCD. A drip tray for condensation/heat transfer fluid must be installed by the responsible body. Periodic checks of hoses and connections are required; refrigerant work must be done by approved contractors.