Peter Huber Kältemaschinenbau Unichiller 040T
Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau Unichiller 040T

Peter Huber Kältemaschinenbau Unichiller 040T — Recirculating chillers with Noise level 69 dB.

The Unichiller 040T is a free-standing, air-cooled recirculating chiller with a single-stage R-449A refrigerant circuit and a fixed-speed pump (type B, G3/4 male). It covers -10 to 40 °C and is rated for 400 V 3~ 50 Hz with a 3x10 A fuse. It serves externally closed process loops requiring up to 69 dB(A) acoustic tolerance.

Noise level
69 dB

Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection

Model Noise level, dBPump connectionPump typeSafety classTemperature range, °CPower supply
Unichiller 040T Current 69G3/4 AG maleBI / NFL-10–40400V 3~ 50Hz
Unichiller 030T 69G3/4 AG maleBI / NFL-10–40460V 3~ 60Hz
Unichiller 030Tw 61G3/4 AG maleBI / NFL-20–40400V 3~ 50Hz
Unichiller 040T-H 69G3/4 AG maleBIII / FL-10–100400V 3~ 50Hz
Unichiller 040Tw 70G3/4 AG maleBI / NFL-10–40400V 3~ 50Hz
Unichiller 040Tw-H 70G3/4 AG maleBIII / FL-10–100400V 3~ 50Hz
Unichiller 050-H 62G1 1/4 AG maleE1III / FL-20–100400V 3~ 50Hz
Unichiller 050w-H 62G1 1/4 AG maleE1III / FL-20–100460V 3~ 60Hz
Unichiller 055T —G1 1/4 AG maleC3I / NFL-20–40400V 3~ 50Hz
Unichiller 055T-H 74G1 1/4 AG maleC3III / FL-20–100400V 3~ 50Hz
Unichiller 055Tw —G1 1/4 AG maleC3I / NFL-20–40400V 3~ 50Hz
Unichiller 060T —G1 1/4 AG maleC3I / NFL-20–40400V 3~ 50Hz
Unichiller 060T-H —G1 1/4 AG maleC3III / FL-20–100400V 3~ 50Hz
Unichiller 060Tw-H —G1 1/4 AG maleC3III / FL-20–100400V 3~ 50Hz
Unichiller 070T-H 66G1 1/4 AG maleC3III / FL-10–100400V 3~ 50Hz
Unichiller 070Tw-H —G1 1/4 AG maleC3III / FL-10–100400V 3~ 50Hz
Unichiller 075w —G1 1/4 AG maleE1I / NFL-20–40400V 3~ 50Hz
Unichiller 075w-H —G1 1/4 AG maleE1III / FL-20–100400V 3~ 50Hz
Unichiller 100-H 58G1 1/4 AG maleE1III / FL-20–100460V 3~ 60Hz
Unichiller 100T —G1 1/4 AG maleC3I / NFL-20–40400V 3~ 50Hz
Unichiller 100T-H —G1 1/4 AG maleC3III / FL-20–100400V 3~ 50Hz
Unichiller 100Tw 65G1 1/4 AG maleC3I / NFL-20–40400V 3~ 50Hz
Unichiller GL 035w —G1 1/4 AG malePressure pump, speed notI / NFL-20–40460V 3~ 60Hz
Unichiller GL 050w —G1 1/4 AG malePressure pump, speed notI / NFL-20–40460V 3~ 60Hz
Unichiller GL 075 —G1 1/4 AG malePressure pump, speed notI / NFL-20–40460V 3~ 60Hz
Unichiller GL 075w —G1 1/4 AG malePressure pump, speed notI / NFL-20–40460V 3~ 60Hz
Unichiller GL 100w —G1 1/4 AG malePressure pump, speed notI / NFL-20–40400V 3~ 50Hz
Unichiller P050 62G1 1/4 AG maleE2I / NFL-20–40400V 3~ 50Hz
Unichiller P050w 62G1 1/4 AG maleE2I / NFL-20–40400V 3~ 50Hz
Unichiller P050w-H 62G1 1/4 AG maleE2III / FL-20–100—
Unichiller P075 61G1 1/4 AG maleE2I / NFL-20–40400V 3~ 50Hz
Unichiller P075w —G1 1/4 AG maleE2I / NFL-20–40400V 3~ 50Hz
Unichiller P075w-H —G1 1/4 AG maleE2III / FL-20–100400V 3~ 50Hz
Unichiller P100 —G1 1/4 AG maleE2I / NFL-20–40460V 3~ 60Hz
Unichiller P100-H —G1 1/4 AG maleE2III / FL-20–100400V 3~ 50Hz
Unichiller P100w 58G1 1/4 AG maleE2I / NFL-20–40400V 3~ 50Hz
Unichiller P100w-H 58G1 1/4 AG maleE2III / FL-20–100400V 3~ 50Hz

Full specifications

Core Performance & Functional Specifications
Noise level 69 dB(A)
Pump connection G3/4 AG male
Pump speed adjustable no
Pump type B
External sensor connection Pt100
Temperature range -10...40 °C
Dimensions, Weight & Mechanical Design
Weight 167 kg
Electrical, Power & Drive Specifications
Power supply 400V 3~ 50Hz
Interfaces, Connections & Control
Controller Pilot ONE
Digital interface Ethernet, USB (Host u. Device), RS232
Materials, Media & Process Compatibility
Refrigerant R-449A (A1, H280) (1st stage)
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C
Protection rating IP20
Standards, Safety & General Data
Safety class I / NFL

Description

Construction and series positioning

Behavior and process limits

Installation and operation

Integration & Operating Notes

Mounting
Maintain 50–200 cm side clearance for service access

Free-standing installation requires a wall clearance of 50 to 200 cm on either side to allow maintenance and airflow. Plan the footprint accordingly; the unit weighs 167 kg and must sit on level ground with leveling feet or parking brakes engaged before start-up.

Unichiller Operation Manual, Installation (p.25, p.31
Electrical
Provide 400 V 3~ 50 Hz supply with 3x10 A fuse and own plug

The chiller is a three-phase device drawing less than 63 A, so it ships with a cable but without a plug; the customer must fit a suitable plug. The electrical installation must be sized for a 3x10 A fuse. Voltage and frequency tolerances must be met simultaneously; a -5% voltage with +2% frequency combination is explicitly not allowed.

Unichiller 040T Technical Data (p.1–2
Process Limits
Use only for externally closed loops; not for open baths

The unit is designed for externally closed applications. The hydraulic circuit must be closed; open vessels or atmospheric baths are outside the intended use. Minimum filling capacity is 3.5 l and expansion volume 3.5 l, so the external loop volume and expansion allowance must be planned accordingly.

Unichiller Operation Manual, Selection (p.34); Technical Data (p.1
Environment
Install indoors, non-ATEX, 5–40 °C ambient, ≥300 lx

The unit must not be installed or started inside an ATEX zone (not explosion-protected). It is for indoor use only, at illuminance of at least 300 lx and up to 2000 m altitude. Ambient temperature must stay within 5–40 °C; cooling capacity is rated at 20 °C and derates at higher ambient. IP20 requires a dry, protected location.

Unichiller Operation Manual, Installation (p.13, p.25); Technical Data (p.1–2

Selection & Integration Q&A

When should I choose the 040T instead of the 030T or 040T-H?

The 040T is the base 40-size air-cooled model for standard temperature control down to -10 °C. Choose 030T for lower capacity needs; 030Tw for water-cooled (61 dB(A)); 040T-H for higher-temperature duty. The 040T has no 'P' high-pressure-drop designation.

What mating hardware and supply provisions are required for the 040T?

Pump connections are G3/4 male, so hoses/fittings must match. Electrical supply is 400 V 3~ 50 Hz with 3x10 A fuse; the unit comes with cable but no plug, so the customer must provide one. External Pt100 sensor can be connected to the controller.

What are the mounting and duty-cycle limits for the 040T?

Install indoors only, not in ATEX zones, at 5–40 °C ambient, ≥300 lx, ≤2000 m altitude. Maintain 50–200 cm side clearance for service. Engage leveling feet/parking brakes before start-up. Cooling capacity derates above 20 °C room temperature.

What maintenance and accessories are needed beyond base delivery?

Refrigerant circuit work requires certified contractors; leak checks apply per 1.9 kg R-449A (2.7 t CO2e). Shut off cooling water even overnight. A mains plug is not included (three-phase <63 A). External Pt100 sensor and process hoses are not part of base delivery.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Unichiller Operation Manual
Manual ·2,8 МБ ·82 pp.
View PDF
PDF
Unichiller 040T Technical Data
Datasheet ·93,7 КБ ·2 pp.
View PDF