Peter Huber Kältemaschinenbau Unichiller P100
Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau Unichiller P100

Peter Huber Kältemaschinenbau Unichiller P100 — Recirculating chillers.

The Unichiller P100 is an air-cooled recirculating chiller with a pressure pump (E2, non-variable speed) and Pilot ONE controller, rated for -20 to 40 °C and 460 V three-phase 60 Hz supply. Its 'P' designation targets externally closed loops with high pressure drop, distinguishing it from the 030T/040T siblings. It serves as a central cooling source for process equipment requiring stable temperature control within its capacity envelope.

Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection

Model Noise level, dBPump connectionPump typeSafety classTemperature range, °CPower supply
Unichiller P100 Current —G1 1/4 AG maleE2I / NFL-20–40460V 3~ 60Hz
Unichiller 030T 69G3/4 AG maleBI / NFL-10–40460V 3~ 60Hz
Unichiller 030Tw 61G3/4 AG maleBI / NFL-20–40400V 3~ 50Hz
Unichiller 040T 69G3/4 AG maleBI / NFL-10–40400V 3~ 50Hz
Unichiller 040T-H 69G3/4 AG maleBIII / FL-10–100400V 3~ 50Hz
Unichiller 040Tw 70G3/4 AG maleBI / NFL-10–40400V 3~ 50Hz
Unichiller 040Tw-H 70G3/4 AG maleBIII / FL-10–100400V 3~ 50Hz
Unichiller 050-H 62G1 1/4 AG maleE1III / FL-20–100400V 3~ 50Hz
Unichiller 050w-H 62G1 1/4 AG maleE1III / FL-20–100460V 3~ 60Hz
Unichiller 055T —G1 1/4 AG maleC3I / NFL-20–40400V 3~ 50Hz
Unichiller 055T-H 74G1 1/4 AG maleC3III / FL-20–100400V 3~ 50Hz
Unichiller 055Tw —G1 1/4 AG maleC3I / NFL-20–40400V 3~ 50Hz
Unichiller 060T —G1 1/4 AG maleC3I / NFL-20–40400V 3~ 50Hz
Unichiller 060T-H —G1 1/4 AG maleC3III / FL-20–100400V 3~ 50Hz
Unichiller 060Tw-H —G1 1/4 AG maleC3III / FL-20–100400V 3~ 50Hz
Unichiller 070T-H 66G1 1/4 AG maleC3III / FL-10–100400V 3~ 50Hz
Unichiller 070Tw-H —G1 1/4 AG maleC3III / FL-10–100400V 3~ 50Hz
Unichiller 075w —G1 1/4 AG maleE1I / NFL-20–40400V 3~ 50Hz
Unichiller 075w-H —G1 1/4 AG maleE1III / FL-20–100400V 3~ 50Hz
Unichiller 100-H 58G1 1/4 AG maleE1III / FL-20–100460V 3~ 60Hz
Unichiller 100T —G1 1/4 AG maleC3I / NFL-20–40400V 3~ 50Hz
Unichiller 100T-H —G1 1/4 AG maleC3III / FL-20–100400V 3~ 50Hz
Unichiller 100Tw 65G1 1/4 AG maleC3I / NFL-20–40400V 3~ 50Hz
Unichiller GL 035w —G1 1/4 AG malePressure pump, speed notI / NFL-20–40460V 3~ 60Hz
Unichiller GL 050w —G1 1/4 AG malePressure pump, speed notI / NFL-20–40460V 3~ 60Hz
Unichiller GL 075 —G1 1/4 AG malePressure pump, speed notI / NFL-20–40460V 3~ 60Hz
Unichiller GL 075w —G1 1/4 AG malePressure pump, speed notI / NFL-20–40460V 3~ 60Hz
Unichiller GL 100w —G1 1/4 AG malePressure pump, speed notI / NFL-20–40400V 3~ 50Hz
Unichiller P050 62G1 1/4 AG maleE2I / NFL-20–40400V 3~ 50Hz
Unichiller P050w 62G1 1/4 AG maleE2I / NFL-20–40400V 3~ 50Hz
Unichiller P050w-H 62G1 1/4 AG maleE2III / FL-20–100—
Unichiller P075 61G1 1/4 AG maleE2I / NFL-20–40400V 3~ 50Hz
Unichiller P075w —G1 1/4 AG maleE2I / NFL-20–40400V 3~ 50Hz
Unichiller P075w-H —G1 1/4 AG maleE2III / FL-20–100400V 3~ 50Hz
Unichiller P100-H —G1 1/4 AG maleE2III / FL-20–100400V 3~ 50Hz
Unichiller P100w 58G1 1/4 AG maleE2I / NFL-20–40400V 3~ 50Hz
Unichiller P100w-H 58G1 1/4 AG maleE2III / FL-20–100400V 3~ 50Hz

Full specifications

Core Performance & Functional Specifications
Expansion volume 48 l
Minimum fill volume 18 l
Pump connection G1 1/4 AG male
Pump speed adjustable no
Pump type E2
External sensor connection Pt100
Temperature range -20...40 °C
Electrical, Power & Drive Specifications
Power supply 460V 3~ 60Hz
Interfaces, Connections & Control
Controller Pilot ONE
Digital interface Ethernet, USB (Host u. Device), RS232
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C
Protection rating IP20
Standards, Safety & General Data
Safety class I / NFL

Description

Construction and series positioning

Performance and load behavior

Installation, control and operation

Integration & Operating Notes

Mounting
Maintain 50–200 cm side clearance for service access

Free-standing installation requires a wall clearance of 50 to 200 cm on either side to allow maintenance and ensure adequate air flow for the air-cooled condenser. Insufficient clearance can lead to reduced cooling capacity and service difficulty.

Unichiller Operation Manual, Section Installation
Electrical
Provide UL 489 branch protection and a suitable plug

The unit requires external branch circuit protection according to UL 489. The three-phase supply (460 V, 60 Hz) is delivered with cable but without a plug, so a matching plug must be provided on site. Voltage and frequency tolerances are ±5 % and ±2 %, not to be combined unfavorably.

Unichiller P100 Datasheet, Technical Specifications; Unichiller Operation Manual, Electrical Connection
Process Limits
Use only for externally closed circuits with high pressure drop

The P100 is designed for externally closed applications and is particularly suitable for high pressure drop loops due to the 'P' designation. Open-loop or low-pressure-drop processes may be better served by sibling models without the 'P' suffix.

Unichiller Operation Manual, Function Description
Cooling & Media
Size cooling capacity at the coldest operating point

Cooling capacity falls from 10 kW at +20 °C to 4 kW at -20 °C. The process load must not exceed the capacity at the minimum required temperature. Ambient temperatures above 20 °C further reduce capacity, so the actual installation room temperature must be considered.

Unichiller P100 Datasheet, Performance Data
Safety
Configure power-failure response and Process Safety mode

The Pilot ONE controller allows selection of power-failure behavior (OFF/Standby, ON, or Power Failure Auto). For exothermic processes, Process Safety mode releases maximum cooling when the overtemperature trigger is reached, preventing runaway. This must be configured according to the process risk assessment.

Unichiller Operation Manual, Setup Mode
Maintenance
Refrigerant work only by approved contractors

Any work on the refrigerant circuit must be performed by approved refrigeration/air-conditioning system contractors. The refrigerant R-449A has a GWP of 1397, so F-gas regulations apply. The expansion tank is atmospheric open and must be kept covered and checked periodically.

Unichiller Operation Manual, Maintenance; Unichiller P100 Datasheet, Safety

Selection & Integration Q&A

When should I choose the Unichiller P100 over the 030T or 040T siblings?

Choose the P100 when the external circuit has high pressure drop, as indicated by the 'P' in the model name. The 030T/040T are not specifically designated for high pressure drop. Also consider the P100's -20 to 40 °C range and 10 kW cooling capacity at +20 °C; select a sibling if those limits are not required.

What are the requirements for connecting the P100 to my process loop?

The pump connection is G1 1/4 male, so hoses and fittings must match this thread. The circuit must be externally closed. Maximum tightening torques for pump connections must not be exceeded, and connections must be counterheld during installation.

What installation environment and duty-cycle limits apply to the P100?

Install indoors only, at 5–40 °C ambient, at least 300 lx illuminance, up to 2000 m altitude, and not in an ATEX zone. Maintain 50–200 cm side clearance. The unit is IP20, so keep it dry and protected from dust. Air-cooled operation requires adequate ventilation.

What maintenance and accessories are required beyond the base delivery?

The base delivery includes a cable but no plug; a suitable 460 V three-phase plug must be provided. External branch circuit protection per UL 489 is required. Refrigerant circuit work must be by approved contractors. The expansion tank must be kept covered and checked. No other accessories are specified in the provided documents.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Unichiller P100
Datasheet ·85,7 КБ ·2 pp.
View PDF
PDF
Unichiller Operation Manual
Manual ·2,8 МБ ·82 pp.
View PDF