Peter Huber Kältemaschinenbau Unichiller 060Tw-H
Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau Unichiller 060Tw-H

Peter Huber Kältemaschinenbau Unichiller 060Tw-H — Recirculating chillers.

The Unichiller 060Tw-H is a water-cooled recirculating chiller with a 2 kW heater and a fixed-speed C3 pump, covering -20 to 100 °C for externally closed circuits. It is the 6 kW-class, water-cooled modification of the Unichiller series, distinguished from air-cooled siblings by its G1/2 cooling-water connection and 1–6 bar differential-pressure requirement.

Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection

Model Noise level, dBPump connectionPump typeSafety classTemperature range, °CPower supply
Unichiller 060Tw-H Current —G1 1/4 AG maleC3III / FL-20–100400V 3~ 50Hz
Unichiller 030T 69G3/4 AG maleBI / NFL-10–40460V 3~ 60Hz
Unichiller 030Tw 61G3/4 AG maleBI / NFL-20–40400V 3~ 50Hz
Unichiller 040T 69G3/4 AG maleBI / NFL-10–40400V 3~ 50Hz
Unichiller 040T-H 69G3/4 AG maleBIII / FL-10–100400V 3~ 50Hz
Unichiller 040Tw 70G3/4 AG maleBI / NFL-10–40400V 3~ 50Hz
Unichiller 040Tw-H 70G3/4 AG maleBIII / FL-10–100400V 3~ 50Hz
Unichiller 050-H 62G1 1/4 AG maleE1III / FL-20–100400V 3~ 50Hz
Unichiller 050w-H 62G1 1/4 AG maleE1III / FL-20–100460V 3~ 60Hz
Unichiller 055T —G1 1/4 AG maleC3I / NFL-20–40400V 3~ 50Hz
Unichiller 055T-H 74G1 1/4 AG maleC3III / FL-20–100400V 3~ 50Hz
Unichiller 055Tw —G1 1/4 AG maleC3I / NFL-20–40400V 3~ 50Hz
Unichiller 060T —G1 1/4 AG maleC3I / NFL-20–40400V 3~ 50Hz
Unichiller 060T-H —G1 1/4 AG maleC3III / FL-20–100400V 3~ 50Hz
Unichiller 070T-H 66G1 1/4 AG maleC3III / FL-10–100400V 3~ 50Hz
Unichiller 070Tw-H —G1 1/4 AG maleC3III / FL-10–100400V 3~ 50Hz
Unichiller 075w —G1 1/4 AG maleE1I / NFL-20–40400V 3~ 50Hz
Unichiller 075w-H —G1 1/4 AG maleE1III / FL-20–100400V 3~ 50Hz
Unichiller 100-H 58G1 1/4 AG maleE1III / FL-20–100460V 3~ 60Hz
Unichiller 100T —G1 1/4 AG maleC3I / NFL-20–40400V 3~ 50Hz
Unichiller 100T-H —G1 1/4 AG maleC3III / FL-20–100400V 3~ 50Hz
Unichiller 100Tw 65G1 1/4 AG maleC3I / NFL-20–40400V 3~ 50Hz
Unichiller GL 035w —G1 1/4 AG malePressure pump, speed notI / NFL-20–40460V 3~ 60Hz
Unichiller GL 050w —G1 1/4 AG malePressure pump, speed notI / NFL-20–40460V 3~ 60Hz
Unichiller GL 075 —G1 1/4 AG malePressure pump, speed notI / NFL-20–40460V 3~ 60Hz
Unichiller GL 075w —G1 1/4 AG malePressure pump, speed notI / NFL-20–40460V 3~ 60Hz
Unichiller GL 100w —G1 1/4 AG malePressure pump, speed notI / NFL-20–40400V 3~ 50Hz
Unichiller P050 62G1 1/4 AG maleE2I / NFL-20–40400V 3~ 50Hz
Unichiller P050w 62G1 1/4 AG maleE2I / NFL-20–40400V 3~ 50Hz
Unichiller P050w-H 62G1 1/4 AG maleE2III / FL-20–100—
Unichiller P075 61G1 1/4 AG maleE2I / NFL-20–40400V 3~ 50Hz
Unichiller P075w —G1 1/4 AG maleE2I / NFL-20–40400V 3~ 50Hz
Unichiller P075w-H —G1 1/4 AG maleE2III / FL-20–100400V 3~ 50Hz
Unichiller P100 —G1 1/4 AG maleE2I / NFL-20–40460V 3~ 60Hz
Unichiller P100-H —G1 1/4 AG maleE2III / FL-20–100400V 3~ 50Hz
Unichiller P100w 58G1 1/4 AG maleE2I / NFL-20–40400V 3~ 50Hz
Unichiller P100w-H 58G1 1/4 AG maleE2III / FL-20–100400V 3~ 50Hz

Full specifications

Core Performance & Functional Specifications
Heating capacity 2 kW
Pump connection G1 1/4 AG male
Pump speed adjustable no
Pump type C3
External sensor connection Pt100
Temperature range -20...100 °C
Dimensions, Weight & Mechanical Design
Weight 210 kg
Electrical, Power & Drive Specifications
Current consumption 13 A (max.)
Power supply 400V 3~ 50Hz
Interfaces, Connections & Control
Controller Pilot ONE
Digital interface Ethernet, USB (Host u. Device), RS232
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C
Cooling water connection G1/2 male
Cooling water consumption 380 л/час (at 15°C, flow -20°C)
at 15°C, flow -10°C: 580 л/час · at 15°C, flow 0°C: 730 l/h · at 15°C, flow 15°C: 870 l/h
Cooling water differential pressure 1 bar (min.)
Cooling Water Pressure 6 bar (max.)
Protection rating IP20
Standards, Safety & General Data
Safety class III / FL

Description

Construction and series positioning

Behavior across the working range

Installation, control and operation

Integration & Operating Notes

Electrical
Three-phase unit ships with cable but no plug

Because current consumption is below 63 A, the 400 V 3~ 50 Hz unit is delivered with a cable only; the installer must provide a suitable plug or hard-wire the supply, and electrical lines directly below the water-cooled unit must be protected against liquid ingress from condensation.

Unichiller 060Tw-H Datasheet, Technical Specifications; Unichiller Operation Manual, Installation
Mounting
Keep 50–200 cm wall clearance per side for maintenance

Free-standing installation requires this side clearance for service access; the unit must be indoors at illuminance of at least 300 lx and up to 2000 m altitude, and must not be installed or started inside an ATEX zone because it is not explosion-protected.

Unichiller Operation Manual, Installation
Mounting
Check refrigerant charge against room volume before siting

The refrigerant charge (R-449A, 1.6 t CO2e) and room size must be checked at installation so the refrigerant limit per m³ of ambient air is not exceeded; this governs the minimum room volume for the installation site.

Unichiller Operation Manual, Installation
Mounting
Secure leveling feet and parking brakes before start-up

Leveling feet must be unscrewed/activated and caster parking brakes applied before the unit is put into operation, otherwise the unit can move during operation and cause crushing injuries.

Unichiller Operation Manual, Normal Operation
Control & I/O
Configure power-failure response to match process restart needs

The Pilot ONE allows OFF/Standby, ON or Power Failure Auto; for exothermic processes, Process Safety mode releases maximum cooling capacity when the OT trigger value is reached instead of switching off all poles.

Unichiller Operation Manual, Setup Mode; Safety

Selection & Integration Q&A

When should I choose the 060Tw-H instead of the air-cooled 030T/030Tw/040T siblings?

Pick the 060Tw-H when a cooling-water loop is available and 6 kW-class duty at 15 °C is needed; the 030T/030Tw/040T are air-cooled and have no cooling-water connection, so they suit sites without water supply but lower capacity.

What must the site provide for the cooling-water and electrical connections?

A cooling-water supply at 5–20 °C intake with 1–6 bar differential pressure and G1/2 male connection, plus a 400 V 3~ 50 Hz supply with 3x16 A fuse; the unit arrives with cable but no plug, so the installer must fit a plug or hard-wire it.

What mounting and environment limits apply to this water-cooled unit?

Indoors only, 5–40 °C ambient, IP20, at least 300 lx illuminance and up to 2000 m altitude; keep 50–200 cm wall clearance per side, secure leveling feet and parking brakes, and protect electrical lines below the unit from condensation.

What is not included in base delivery and what service constraints apply?

No plug is supplied for the three-phase cable, and no external Pt100 sensor or hoses/fittings are listed as included; refrigerant-circuit work must be done by approved refrigeration contractors, and cooling water must be shut off even overnight.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Unichiller Operation Manual
Manual ·2,8 МБ ·82 pp.
View PDF
PDF
Unichiller 060Tw-H Datasheet
Datasheet ·79,6 КБ ·2 pp.
View PDF