Peter Huber Kältemaschinenbau Unichiller GL 050w
Peter Huber Kältemaschinenbau Unichiller GL 050w — Recirculating chillers.
The Unichiller GL 050w is a water-cooled recirculating chiller with a Pilot ONE controller, a fixed-speed pressure pump (max 3.5 bar, 50 l/min) and G1 1/4 male process connections, covering -20 to 40 °C. It delivers 20 kW cooling at 5 °C and is intended for externally closed industrial process loops.
Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection
| Model | Noise level, dB | Pump connection | Pump type | Safety class | Temperature range, °C | Power supply |
|---|---|---|---|---|---|---|
| Unichiller GL 050w Current | — | G1 1/4 AG male | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz |
| Unichiller 030T | 69 | G3/4 AG male | B | I / NFL | -10–40 | 460V 3~ 60Hz |
| Unichiller 030Tw | 61 | G3/4 AG male | B | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller 040T | 69 | G3/4 AG male | B | I / NFL | -10–40 | 400V 3~ 50Hz |
| Unichiller 040T-H | 69 | G3/4 AG male | B | III / FL | -10–100 | 400V 3~ 50Hz |
| Unichiller 040Tw | 70 | G3/4 AG male | B | I / NFL | -10–40 | 400V 3~ 50Hz |
| Unichiller 040Tw-H | 70 | G3/4 AG male | B | III / FL | -10–100 | 400V 3~ 50Hz |
| Unichiller 050-H | 62 | G1 1/4 AG male | E1 | III / FL | -20–100 | 400V 3~ 50Hz |
| Unichiller 050w-H | 62 | G1 1/4 AG male | E1 | III / FL | -20–100 | 460V 3~ 60Hz |
| Unichiller 055T | — | G1 1/4 AG male | C3 | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller 055T-H | 74 | G1 1/4 AG male | C3 | III / FL | -20–100 | 400V 3~ 50Hz |
| Unichiller 055Tw | — | G1 1/4 AG male | C3 | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller 060T | — | G1 1/4 AG male | C3 | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller 060T-H | — | G1 1/4 AG male | C3 | III / FL | -20–100 | 400V 3~ 50Hz |
| Unichiller 060Tw-H | — | G1 1/4 AG male | C3 | III / FL | -20–100 | 400V 3~ 50Hz |
| Unichiller 070T-H | 66 | G1 1/4 AG male | C3 | III / FL | -10–100 | 400V 3~ 50Hz |
| Unichiller 070Tw-H | — | G1 1/4 AG male | C3 | III / FL | -10–100 | 400V 3~ 50Hz |
| Unichiller 075w | — | G1 1/4 AG male | E1 | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller 075w-H | — | G1 1/4 AG male | E1 | III / FL | -20–100 | 400V 3~ 50Hz |
| Unichiller 100-H | 58 | G1 1/4 AG male | E1 | III / FL | -20–100 | 460V 3~ 60Hz |
| Unichiller 100T | — | G1 1/4 AG male | C3 | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller 100T-H | — | G1 1/4 AG male | C3 | III / FL | -20–100 | 400V 3~ 50Hz |
| Unichiller 100Tw | 65 | G1 1/4 AG male | C3 | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller GL 035w | — | G1 1/4 AG male | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz |
| Unichiller GL 075 | — | G1 1/4 AG male | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz |
| Unichiller GL 075w | — | G1 1/4 AG male | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz |
| Unichiller GL 100w | — | G1 1/4 AG male | Pressure pump, speed not | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller P050 | 62 | G1 1/4 AG male | E2 | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller P050w | 62 | G1 1/4 AG male | E2 | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller P050w-H | 62 | G1 1/4 AG male | E2 | III / FL | -20–100 | — |
| Unichiller P075 | 61 | G1 1/4 AG male | E2 | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller P075w | — | G1 1/4 AG male | E2 | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller P075w-H | — | G1 1/4 AG male | E2 | III / FL | -20–100 | 400V 3~ 50Hz |
| Unichiller P100 | — | G1 1/4 AG male | E2 | I / NFL | -20–40 | 460V 3~ 60Hz |
| Unichiller P100-H | — | G1 1/4 AG male | E2 | III / FL | -20–100 | 400V 3~ 50Hz |
| Unichiller P100w | 58 | G1 1/4 AG male | E2 | I / NFL | -20–40 | 400V 3~ 50Hz |
| Unichiller P100w-H | 58 | G1 1/4 AG male | E2 | III / FL | -20–100 | 400V 3~ 50Hz |
Full specifications
| Pump connection | G1 1/4 AG male |
| Pump speed adjustable | no |
| Pump type | Pressure pump, speed not variable |
| External sensor connection | Pt100 |
| Temperature range | -20...40 °C |
| Power supply | 460V 3~ 60Hz |
| Controller | Pilot ONE |
| Digital interface | Ethernet, USB (Host u. Device), RS232 |
| Ambient temperature limit | 5...40 °C |
| Cooling capacity | 20 kW (at 5 °C) |
| Cooling water connection | G1/2 male |
| Cooling water differential pressure | 1 bar (min) |
| Cooling Water Pressure | 6 bar (max) |
| Protection rating | IP20 |
| Safety class | I / NFL |
Description
Construction and series positioning
- Water-cooled refrigeration circuit using R-744 (CO2), requiring a cooling water supply at G1/2 male connections with 1–6 bar differential pressure.
- Fixed-speed pressure pump (not speed-variable) with G1 1/4 AG male process connections; maximum delivery pressure 3.5 bar and maximum flow 50 l/min.
- Pilot ONE controller with Ethernet, USB (host and device) and RS232 interfaces; external Pt100 sensor input.
- IP20 protection, safety class I / NFL. Sibling models in the Unichiller series (030T, 030Tw, 030Tw-H, 040T) are air-cooled variants with published noise levels; the GL 050w is distinguished by its water-cooled condenser and higher 20 kW capacity at 5 °C.
Behavior under load and media
- Cooling capacity is 20 kW at 5 °C; the datasheet notes that as cooling water temperature rises, cooling power drops and required cooling water flow may increase.
- Cooling water inlet temperature must be 5–20 °C; lower inlet temperatures require insulation of the cooling water pipes to prevent condensation.
- The cooling water circuit contains copper, stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM, so the water must be chemically compatible with these materials.
- Process loop must be externally closed; models with “P” in the name are for high pressure drop, which this model is not.
Installation, control and operation
- Ambient temperature 5–40 °C; indoor use only, illuminance at least 300 lx, altitude up to 2000 m.
- Wall clearance of 50–200 cm per side required for maintenance on free-standing models; leveling feet or parking brakes must be set before start-up.
- Power supply 460 V 3~ 60 Hz; voltage tolerance ±5% with simultaneous frequency tolerance ±2%, but combinations such as -5% voltage and +2% frequency are not permitted. External branch circuit protection per UL 489 required; three-phase units under 63 A are supplied with cable but without plug.
- Power-failure response configurable via Pilot ONE as OFF/Standby, ON, or Power Failure Auto. Process Safety mode releases maximum cooling capacity when the overtemperature trigger is reached instead of switching off all poles.
- Shut off cooling water supply even for short downtimes (e.g. overnight). Electrical lines directly below the unit must be protected against liquid ingress from condensation.
Integration & Operating Notes
Operating with cooling water below 5 °C or above 20 °C is outside the design range; lower inlet temperatures require insulated cooling water pipes to prevent condensation on the circuit and possible electrical hazard.
The supply must remain within ±5% voltage and ±2% frequency, but the datasheet explicitly forbids simultaneous worst-case combinations such as -5% voltage with +2% frequency; verify the site supply against both limits before connection.
External branch circuit protection according to UL 489 is mandatory. Three-phase devices drawing less than 63 A are delivered with a cable but without a plug, so the installer must supply a suitable plug or hardwire the connection.
Free-standing models require a wall clearance of 50 to 200 cm on either side to allow maintenance access. The unit must be installed indoors at illuminance of at least 300 lx and at altitudes up to 2000 m, and must not be placed in an ATEX zone.
Because the unit is water-cooled, condensate can form; electrical lines running directly below the chiller must be protected against liquid ingress to avoid shock hazard.
The chiller is designed only for externally closed applications; open baths or circuits that expose the thermal fluid to atmosphere are not permitted and would invalidate the intended hydraulic design.
The Pilot ONE allows the power-failure response to be set to OFF/Standby, ON, or Power Failure Auto. For exothermic processes, Process Safety mode releases maximum cooling capacity when the overtemperature trigger is reached instead of switching off all poles.
Any work on the refrigerant circuit must be carried out by approved refrigeration/air-conditioning system contractors. The refrigerant is R-744 (CO2) under pressure (GHS H280), so handling requires qualified personnel.
The cooling water supply must be shut off during any downtime, including short overnight stops, to prevent water damage and corrosion in the circuit.
Before the unit is put into operation, the parking brakes at the casters (if any) must be activated and/or the leveling feet unscrewed/activated to prevent the unit from moving and causing crushing injuries.
Selection & Integration Q&A
Choose the GL 050w when you need 20 kW cooling at 5 °C and have a cooling water supply (G1/2, 1–6 bar differential). The 030T/040T are air-cooled with published noise levels and lower capacity; they suit sites without cooling water but add fan noise and reject heat to the room.
Cooling water at 5–20 °C inlet, differential pressure 1–6 bar, G1/2 male connections. Circuit materials include copper, stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM, so the water must be compatible; lower inlet temperatures require pipe insulation.
Indoor use only, ambient 5–40 °C, illuminance ≥300 lx, altitude ≤2000 m, no ATEX zone. Keep 50–200 cm clearance per side for maintenance. Shut off cooling water during any downtime, including overnight. Set leveling feet or parking brakes before start-up.
Refrigerant circuit work only by approved refrigeration contractors. External UL 489 branch protection and a plug or hardwire are installer-supplied (cable included, plug not). No process hoses or fittings are listed as included; provide G1 1/4 male mating connections and G1/2 cooling water fittings.