Peter Huber Kältemaschinenbau Unichiller 025 OLÉ
Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau Unichiller 025 OLÉ

Peter Huber Kältemaschinenbau Unichiller 025 OLÉ — Recirculating chillers with Noise level 64 dB.

The Unichiller 025 OLÉ is an air-cooled recirculating chiller with an immersion pump and the OLÉ controller, rated for -10 to 40 °C in externally closed loops. It is the 025-capacity member of the Unichiller series, distinguished from the 015 siblings by higher cooling output and 64 dB(A) noise. It serves industrial process cooling at 208-230 V, 60 Hz.

Noise level
64 dB

Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection

Model Noise level, dBControllerSafety classTemperature range, °CInterfacePower supply
Unichiller 025 OLÉ Current 64OLÉI / NFL-10–40USB (Device), RS232 Inte208-230V 1~/2~ 60Hz
Unichiller 015 63Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 015-H 63Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50Hz
Unichiller 015-H OLÉ 63OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 015w-H 54Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 015w-H OLÉ 54OLÉI / NFL-20–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 017T 64Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 017T-H 64Pilot ONEI / NFL-10–100Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 017Tw-H 64Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D208V 2~ 60Hz
Unichiller 020T —Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 020T-H —Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D208V 2~ 60Hz
Unichiller 020Tw 60Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 020Tw-H 60Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 022-H 65Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 022-H OLÉ 65OLÉI / NFL-10–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 022 OLÉ 65OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 022w 60Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 022w-H —Pilot ONEIII / FL-10–100——
Unichiller 022w OLÉ 60OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 025-H 64Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 025-H OLÉ 64OLÉIII / FL-10–100USB (Device), RS232 Inte208-230V 1~/2~ 60Hz
Unichiller 025T 74Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 025T-H 74Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 025Tw-H —Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 025w 60Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 025w-H OLÉ 60OLÉIII / FL-10–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 025w OLÉ 60OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P007 58Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D208-240V 1~/2~ 50/60Hz
Unichiller P007-H —Pilot ONEIII / FL-20–100——
Unichiller P007-H OLÉ 58OLÉIII / FL-20–100USB (Device), RS232 Inte208-240V 1~/2~ 50/60Hz
Unichiller P007 OLÉ 58OLÉI / NFL-20–40USB (Device), RS232 Inte208-240V 1~/2~ 50/60Hz
Unichiller P010 57Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D208V 2~ 60Hz
Unichiller P010-H 57Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P010-H OLÉ 57OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~/2~ 50/60Hz
Unichiller P010 OLÉ 57OLÉI / NFL-20–40USB (Device), RS232 Inte110-120V 1~ 50/60Hz
Unichiller P010w —Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P010w-H —Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P012 59Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D208V 2~ 60Hz
Unichiller P012-H 59Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P012-H OLÉ 59OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~/2~ 50/60Hz
Unichiller P012 OLÉ 59OLÉI / NFL-20–40USB (Device), RS232 Inte220-240V 1~/2~ 50/60Hz
Unichiller P012w-H —Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P012w-H OLÉ —OLÉIII / FL-20–100USB (Device), RS232 Inte208V 2~ 60Hz
Unichiller P012w OLÉ —OLÉI / NFL-20–40USB (Device), RS232 Inte220-240V 1~/2~ 50/60Hz
Unichiller P015 63Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D220-240V 1~/2~ 50Hz
Unichiller P015-H 63Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P015-H OLÉ 63OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P015 OLÉ 63OLÉI / NFL-20–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P015w 54Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D220-240V 1~/2~ 50Hz
Unichiller P015w-H 54Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D208-230V 1~/2~ 60Hz
Unichiller P015w-H OLÉ 54OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~/2~ 50Hz
Unichiller P022 65Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P022-H 65Pilot ONEI / NFL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P022-H OLÉ 65OLÉI / NFL-10–100USB (Device), RS232 Inte208-230V 1~/2~ 60Hz
Unichiller P022 OLÉ 65OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P022w 60Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D208-230V 1~/2~ 60Hz
Unichiller P022w-H 60Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P022w OLÉ 60OLÉI / NFL-10–40USB (Device), RS232 Inte208-230V 1~/2~ 60Hz
Unichiller P025 64Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P025-H 64Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P025-H OLÉ 64OLÉIII / FL-10–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P025 OLÉ 64OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P025w 60Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D208-230V 1~/2~ 60Hz
Unichiller P025w-H OLÉ 60OLÉIII / FL-10–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P025w OLÉ 60OLÉI / NFL-10–40USB (Device), RS232 Inte208-230V 1~/2~ 60Hz

Full specifications

Core Performance & Functional Specifications
Noise level 64 dB(A)
Maximum delivery flow rate 29 l/min (also 1 bar max pressure)
Pump connection G3/4 AG male
Pump speed adjustable no
Pump type Immersion pump
Temperature range -10...40 °C
Dimensions, Weight & Mechanical Design
Weight 78 kg
Electrical, Power & Drive Specifications
Current consumption 12 A
Fuse rating 16 A
Power supply 208-230V 1~/2~ 60Hz
Interfaces, Connections & Control
Controller OLÉ
Display resolution 0, 1 K
Digital interface USB (Device), RS232 Interface
Temperature display OLED Display
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C
Protection rating IP20
Standards, Safety & General Data
Safety class I / NFL

Description

Construction and series positioning

Working range and behavior

Installation, control and operation

Integration & Operating Notes

Electrical
Supply must stay within ±5% V and ±2% Hz, not combined oppositely

Voltage tolerance is ±5% and frequency tolerance ±2%, but the two must not be combined in opposite directions. Verify supply quality before installation; an out-of-tolerance supply can damage the compressor. The 16 A fuse and 12 A draw define the branch circuit.

Unichiller 025 OLÉ Technical Datasheet, Specifications
Electrical
Country-specific plug must be specified at order

Single/two-phase devices are delivered with a power cable and country-specific plug only if specified when ordering. Without this, the unit may arrive without the correct local plug and commissioning is delayed.

Unichiller 025 OLÉ Technical Datasheet, Specifications
Mounting
Plan 50-200 cm wall clearance per side for maintenance

Free-standing models require a wall clearance of 50 to 200 cm on either side. Air-cooled condenser airflow clearance must also be respected per the operating conditions; insufficient space reduces cooling capacity and can cause overheating.

Unichiller Operation Manual, Installation
Mounting
Indoor only, 300 lx minimum, max 2000 m altitude, no ATEX zone

The unit may only be used indoors at an illuminance of at least 300 lx and up to 2000 m altitude. It must not be installed or started up inside an ATEX zone because it is not explosion-protected. IP20 also rules out wet or dusty locations.

Unichiller Operation Manual, Installation
Process Limits
Externally closed loops only; no acetone or polyglycols

The unit is designed for externally closed applications. The plastic pump is not resistant to acetone or polyglycols, so these must not be used as heat transfer media without a more resistant pump option. For freeze protection, mix water with glysantine or ethylene glycol.

Unichiller Operation Manual, Function Description; Unichiller 025 OLÉ Technical Datasheet
Process Limits
Do not exceed tightening torque on G3/4 pump connections

Maximum tightening torques for the G3/4 AG male pump connections must not be exceeded, and connections must be counterheld during hose installation to prevent damage and leaks.

Unichiller Operation Manual, Installation
Control & I/O
Configure power-failure response before unattended operation

The power-failure response can be set to OFF/Standby, ON, or Power Failure Auto via the controller, and the OLÉ controller includes an autostart function after power failure. For unattended processes, decide whether automatic restart is acceptable or external interlocks are needed.

Unichiller Operation Manual, Normal Operation; Unichiller 025 OLÉ Technical Datasheet
Control & I/O
Use Process Safety mode for exothermic reactions

Process Safety mode releases maximum cooling capacity when the overtemperature trigger value is reached instead of switching off all poles. This is critical for exothermic processes where cutting cooling would cause runaway temperatures.

Unichiller Operation Manual, Safety
Cooling & Media
Shut off cooling water even for overnight downtime

Cooling water supply must be shut off even for short downtimes such as overnight to prevent water damage and corrosion. Electrical lines directly below a water-cooled unit must be protected against liquid ingress from condensation.

Unichiller Operation Manual, Installation/Operation
Maintenance
Refrigerant circuit work only by approved contractors

Work on the coolant circuit must be carried out by approved refrigeration/air-conditioning system contractors. The refrigerant R-449A is classified A1 with GHS hazard H280 (pressurized gas), so handling and disposal follow pressurized-gas safety rules.

Unichiller Operation Manual, Maintenance; Unichiller 025 OLÉ Technical Datasheet
Maintenance
Activate leveling feet and parking brakes before start-up

The parking brakes must be activated at the casters (if any) and/or the leveling feet must be unscrewed/activated before the unit is put into operation, to prevent movement and crushing injuries during operation.

Unichiller Operation Manual, Commissioning

Selection & Integration Q&A

When should I choose the Unichiller 025 OLÉ instead of the 015 or 015-H variants?

Pick the 025 when your heat load needs the larger capacity of this modification; the 015/015-H siblings are smaller and rated 63 dB(A) versus 64 dB(A) here. If your loop has high pressure drop, note that only models with "P" in the name are suited to that, not this unit.

What supply and protection does the 025 OLÉ need, and what about the plug?

It requires 208-230 V 1~/2~ 60 Hz with a 16 A fuse and draws up to 12 A. Voltage and frequency tolerances are ±5% and ±2% but must not be combined oppositely. The country-specific plug must be specified at ordering or the unit may arrive without it.

Where can the unit be installed and what clearances apply?

Indoors only, 5-40 °C ambient, at least 300 lx illuminance, up to 2000 m altitude, never in an ATEX zone. Free-standing models need 50-200 cm wall clearance per side for maintenance, plus condenser airflow clearance; IP20 rules out wet or dusty sites.

What maintenance and accessories are not included in the base delivery?

The power cable and country-specific plug are only included if specified at order. The optional Pt100 sensor connection for external process temperature display is factory-fitted only and must be ordered with the unit. Refrigerant circuit service requires approved contractors.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Unichiller Operation Manual
Manual ·2,8 МБ ·82 pp.
View PDF
PDF
Unichiller 025 OLÉ Technical Datasheet
Datasheet ·117,2 КБ ·2 pp.
View PDF