Peter Huber Kältemaschinenbau Unichiller 020T
Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau Unichiller 020T

Peter Huber Kältemaschinenbau Unichiller 020T — Recirculating chillers.

The Unichiller 020T is an air-cooled, externally closed recirculating chiller rated -20 to 40 °C, with 2 kW cooling at 0 °C falling to 0.8 kW at -20 °C. It is the 020T modification of the Unichiller series, distinguished by its 25 l/min non-adjustable pump and G3/4 male connections. It serves as the cooling source for closed process loops within its capacity envelope.

Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection

Model Noise level, dBControllerSafety classTemperature range, °CInterfacePower supply
Unichiller 020T Current —Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 015 63Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 015-H 63Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50Hz
Unichiller 015-H OLÉ 63OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 015w-H 54Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 015w-H OLÉ 54OLÉI / NFL-20–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 017T 64Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 017T-H 64Pilot ONEI / NFL-10–100Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 017Tw-H 64Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D208V 2~ 60Hz
Unichiller 020T-H —Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D208V 2~ 60Hz
Unichiller 020Tw 60Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 020Tw-H 60Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 022-H 65Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 022-H OLÉ 65OLÉI / NFL-10–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 022 OLÉ 65OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 022w 60Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 022w-H —Pilot ONEIII / FL-10–100——
Unichiller 022w OLÉ 60OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 025-H 64Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 025-H OLÉ 64OLÉIII / FL-10–100USB (Device), RS232 Inte208-230V 1~/2~ 60Hz
Unichiller 025 OLÉ 64OLÉI / NFL-10–40USB (Device), RS232 Inte208-230V 1~/2~ 60Hz
Unichiller 025T 74Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 025T-H 74Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 025Tw-H —Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D230V 1~ 50Hz
Unichiller 025w 60Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller 025w-H OLÉ 60OLÉIII / FL-10–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller 025w OLÉ 60OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P007 58Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D208-240V 1~/2~ 50/60Hz
Unichiller P007-H —Pilot ONEIII / FL-20–100——
Unichiller P007-H OLÉ 58OLÉIII / FL-20–100USB (Device), RS232 Inte208-240V 1~/2~ 50/60Hz
Unichiller P007 OLÉ 58OLÉI / NFL-20–40USB (Device), RS232 Inte208-240V 1~/2~ 50/60Hz
Unichiller P010 57Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D208V 2~ 60Hz
Unichiller P010-H 57Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P010-H OLÉ 57OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~/2~ 50/60Hz
Unichiller P010 OLÉ 57OLÉI / NFL-20–40USB (Device), RS232 Inte110-120V 1~ 50/60Hz
Unichiller P010w —Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P010w-H —Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P012 59Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D208V 2~ 60Hz
Unichiller P012-H 59Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P012-H OLÉ 59OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~/2~ 50/60Hz
Unichiller P012 OLÉ 59OLÉI / NFL-20–40USB (Device), RS232 Inte220-240V 1~/2~ 50/60Hz
Unichiller P012w-H —Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~/2~ 50/60Hz
Unichiller P012w-H OLÉ —OLÉIII / FL-20–100USB (Device), RS232 Inte208V 2~ 60Hz
Unichiller P012w OLÉ —OLÉI / NFL-20–40USB (Device), RS232 Inte220-240V 1~/2~ 50/60Hz
Unichiller P015 63Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D220-240V 1~/2~ 50Hz
Unichiller P015-H 63Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P015-H OLÉ 63OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P015 OLÉ 63OLÉI / NFL-20–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P015w 54Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D220-240V 1~/2~ 50Hz
Unichiller P015w-H 54Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D208-230V 1~/2~ 60Hz
Unichiller P015w-H OLÉ 54OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~/2~ 50Hz
Unichiller P022 65Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P022-H 65Pilot ONEI / NFL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P022-H OLÉ 65OLÉI / NFL-10–100USB (Device), RS232 Inte208-230V 1~/2~ 60Hz
Unichiller P022 OLÉ 65OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P022w 60Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D208-230V 1~/2~ 60Hz
Unichiller P022w-H 60Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P022w OLÉ 60OLÉI / NFL-10–40USB (Device), RS232 Inte208-230V 1~/2~ 60Hz
Unichiller P025 64Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P025-H 64Pilot ONEIII / FL-10–100Ethernet, USB (Host u. D220-240V 1~ 50Hz
Unichiller P025-H OLÉ 64OLÉIII / FL-10–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P025 OLÉ 64OLÉI / NFL-10–40USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P025w 60Pilot ONEI / NFL-10–40Ethernet, USB (Host u. D208-230V 1~/2~ 60Hz
Unichiller P025w-H OLÉ 60OLÉIII / FL-10–100USB (Device), RS232 Inte220-240V 1~ 50Hz
Unichiller P025w OLÉ 60OLÉI / NFL-10–40USB (Device), RS232 Inte208-230V 1~/2~ 60Hz

Full specifications

Core Performance & Functional Specifications
Expansion volume 2 l
Maximum delivery flow rate 25 l/min (pressure pump max; also 3 bar)
Pump connection G3/4 AG male
Pump speed adjustable no
Pump type B
External sensor connection Pt100
Temperature range -20...40 °C
Dimensions, Weight & Mechanical Design
Weight 143 kg
Electrical, Power & Drive Specifications
Current consumption 13 A (max)
Fuse rating 16 A
Power supply 230V 1~ 50Hz
Interfaces, Connections & Control
Controller Pilot ONE
Digital interface Ethernet, USB (Host u. Device), RS232
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C (permissible ambient temperature)
Protection rating IP20
Standards, Safety & General Data
Safety class I / NFL

Description

Construction and series positioning

The 020T is a free-standing, air-cooled recirculating chiller with a 143 kg cabinet, IP20 protection, and a Pilot ONE controller. Within the Unichiller series it sits alongside the 015 variants (015, 015-H, 015-H OLÉ, 015 OLÉ), which share a 63 dB(A) noise figure; the 020T is the larger-capacity modification in this fact set. It is intended only for externally closed applications; open tanks are not suitable. The pump is a non-adjustable type B unit with G3/4 male connections, delivering up to 25 l/min and 5 l/min at 3 bar.

Thermal behavior and media

Cooling capacity is quoted at 20 °C room temperature: 2 kW at 0 °C and 0.8 kW at -20 °C, so low-temperature duty requires either reduced heat load or a larger unit. Capacity falls as ambient temperature rises above 20 °C. The refrigerant is R-449A (GWP 1397, charge 1.2 kg, 1.7 t CO2 equivalent). Minimum filling capacity is 2.5 l with 2 l expansion volume. The unit is classified to DIN 12876 with NFL/FL identification depending on whether the thermal fluid is combustible.

Installation, control and operation

The unit requires a 230 V 1~ 50 Hz supply, 16 A fuse, and draws up to 13 A; voltage tolerance ±5% and frequency ±2% must not be combined in opposite directions. It is Class A, Group 1 to EN55011. Interfaces include Ethernet, USB host/device, RS232, and an external Pt100 sensor connection. The Pilot ONE allows configuration of the power-failure response (OFF/Standby, ON, Power Failure Auto) and a Process Safety mode that releases maximum cooling when the overtemperature trigger is reached. Installation requires 50–200 cm wall clearance per side, indoor use at ≥300 lx and up to 2000 m altitude, and no ATEX zone. Leveling feet or parking brakes must be set before start-up.

Integration & Operating Notes

Process Limits
Closed-loop process only; open tanks are not supported

The hydraulic circuit must be externally closed. An open tank or unsealed reservoir will not match the unit's design and can cause overflow, air ingress, or incorrect expansion behavior. Verify the loop is sealed before commissioning.

Unichiller Operation Manual, p. 34; Unichiller 020T Technical Data, p. 1
Electrical
Supply tolerances must not be combined in opposite directions

Voltage tolerance is ±5% and frequency tolerance ±2%, but the datasheet forbids applying them simultaneously in opposite directions. Check the actual supply quality at the installation point; a 230 V/50 Hz nominal with high voltage and low frequency (or vice versa) is outside the permitted envelope.

Unichiller 020T Technical Data, p. 2
Mounting
Maintain 50–200 cm side clearance for service access

Free-standing installation requires a wall clearance of 50 to 200 cm on either side for maintenance. Air-cooled units also reject heat to the room, so ambient temperature must stay between 5 and 40 °C and the room must be ventilated accordingly.

Unichiller Operation Manual, p. 25
Mounting
Not permitted in ATEX zones; indoor use only

The unit is not explosion-protected and must not be installed or started inside an ATEX zone. It is for indoor use at illuminance ≥300 lx and altitude up to 2000 m. Refrigerant charge and room volume must be checked against the refrigerant limit per m³ of ambient air.

Unichiller Operation Manual, p. 13, p. 15, p. 25
Process Limits
Check pump curve against loop pressure drop

The pump delivers 25 l/min maximum and 5 l/min at 3 bar. The external circuit pressure drop must be checked against this curve; a high-drop loop will reduce flow below the required rate. Models with 'P' in the model name are specifically suited to high-pressure-drop applications, which the 020T is not designated as.

Unichiller 020T Technical Data, p. 1; Unichiller Operation Manual, p. 34
Control & I/O
Configure power-failure response before unattended operation

The Pilot ONE can be set to OFF/Standby, ON, or Power Failure Auto after a mains outage. For exothermic processes, Process Safety mode releases maximum cooling when the overtemperature trigger is reached instead of switching off all poles. Select the mode that matches the process risk before leaving the unit unattended.

Unichiller Operation Manual, p. 18–19
Maintenance
Refrigerant circuit work requires approved contractors

Any work on the refrigerant circuit must be carried out by approved refrigeration/air-conditioning system contractors. The unit contains R-449A (1.2 kg, 1.7 t CO2 equivalent), so leak reporting and environmental compliance obligations apply.

Unichiller Operation Manual, p. 17; Unichiller 020T Technical Data, p. 1
Mounting
Counterhold pump connections at G3/4 male threads

Maximum tightening torques for the G3/4 male pump connections must not be exceeded, and the connections must be counterheld during hose installation to avoid damaging the pump housing or creating leaks.

Unichiller Operation Manual, p. 28; Unichiller 020T Technical Data, p. 1

Selection & Integration Q&A

When should I choose the Unichiller 020T instead of a 015 variant?

Choose the 020T when the required cooling capacity at the coldest operating point exceeds what the 015 variants provide; the 020T delivers 2 kW at 0 °C and 0.8 kW at -20 °C. The 015 variants share a 63 dB(A) noise figure, so if noise is the deciding factor, compare against that figure. The 020T is not designated for high-pressure-drop loops (no 'P' in the model name).

What maintenance and consumables are required, and what is not included in base delivery?

Refrigerant circuit work must be done by approved refrigeration contractors. The unit needs a minimum 2.5 l fill with 2 l expansion volume; heat-transfer fluid is not included. The country-specific plug must be specified at order. No maintenance interval is stated in the provided digests; consult the manual's Maintenance section.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Unichiller Operation Manual
Manual ·2,8 МБ ·82 pp.
View PDF
PDF
Unichiller 020T Technical Data
Datasheet ·97,6 КБ ·2 pp.
View PDF